Aurelia Robust Nitrile Exam Gloves — 4.5 mil, Medical Grade, Blue, 1,000 Gloves per Case (10 × 100)
Ships to the US · US$9.99 flat, free over $300
Specifications
| Film thickness | 4.5 mil |
|---|---|
| Material | Nitrile, powder-free, latex-free |
| Surface | Micro-textured for wet and dry grip |
| SKU | AUR-NG-ROB-45-S |
| Brand | Supermax Healthcare Canada (Aurelia) |
| Category | Hand Protection |
| Availability | In stock |
Pricing
| Order | Unit price |
|---|---|
| 1 unit | $78.99 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 10 sections · specs, use, compliance
These are Aurelia Robust nitrile examination gloves at 4.5 mil, powder-free and fully textured, in blue, packed 1,000 gloves to a case as ten boxes of 100, and the fully textured surface is the reason clinics choose them for long, wet appointments where a smooth glove becomes slippery.

What does "fully textured" change in a clinic?
Texturing is the surface finish moulded into the film, and it decides how a wet glove behaves in the hand. A smooth nitrile glove that has been in contact with water, saliva or irrigant for twenty minutes loses grip; a textured glove keeps a mechanical bite on an instrument handle even when the surface of the glove is wet. This glove is described by the manufacturer as micro-textured for wet and dry grip across the whole glove rather than only at the fingertips, and the practical consequence is fewer dropped instruments and less grip force needed to hold a handpiece.
The second consequence is durability. A 4.5 mil film resists snagging on a sharp edge better than a 3.2 mil film, which is why the heavier weights are chosen for procedures that involve a bur, a scaler tip, or a rough surface. That does not make it a cut-resistant glove — no examination glove is — but it changes how long a pair survives before it has to be changed for a visible defect.

How does 4.5 mil compare with the rest of the range?
The Aurelia range covers 3.2, 4.0 and 4.5 mil, and the differences are about handling rather than about barrier class: all three are examination gloves made to the nitrile glove specification. Choosing between them is a question of what the appointment demands from the film, and the answer is usually to stock two weights rather than three.
| Property | 3.2 mil | 4.0 mil | 4.5 mil (this glove) |
|---|---|---|---|
| Film weight | Thin | Middle | Heaviest in the range |
| Surface | Smooth to lightly textured | Micro-textured palm | Fully micro-textured, wet and dry grip |
| Feel | Highest tactile transmission | Balanced | Reduced feel, higher grip |
| Typical fit | Short examination, hygiene checks | General examination, restorative | Long wet procedures, heavy handling |
| Change frequency | High, film is thin | Moderate | Lower, film tolerates longer wear |
Which tasks should move up to a 4.5 mil glove?
The trigger is not the procedure name but the combination of time, moisture and instrument handling. An appointment that runs forty minutes with continuous irrigation, a hygiene visit where a scaler runs through a full mouth, and a maintenance session that alternates between a wet instrument and a dry one are all situations where the heavier, textured film earns its place. Short examination encounters usually do not.
| Situation | What the glove has to do | 4.5 mil textured |
|---|---|---|
| Long restorative appointment, wet field | Keep grip on a handpiece and an aspirator tip while wet | Yes — the case this glove was designed for |
| Full-mouth ultrasonic scaling | Aerosol and continuous moisture, instrument changes | Yes |
| Clinical cleanup between patients | Wet surfaces, disinfectant, occasional sharp edges | Yes, but consider a dedicated utility glove |
| Short examination or triage | Feel and fast donning | No — the 3.2 or 4.0 mil film is the better match |
| Fine tactile work on small anatomy | Maximum sensation through the film | No — tactile transmission is reduced at this weight |
Does a thicker glove actually reduce failures in use?
Partly, and it is worth separating what the evidence does and does not show. A prospective study of 1,500 used examination glove pairs on two intensive care units found micro-perforations in 10.3% of pairs, with durability differences between brands that the manufacturers' technical data did not predict, and recommended changing gloves after roughly 15 minutes as a compromise between safety and practicality. A laboratory study of 30 nitrile exam products tested out of the box and after two hours of simulated movement found that movement changed leak results — some products that passed when new did not pass after use.
Neither study says that a heavier film is a substitute for changing gloves. What they establish is that wear time and handling are the variables that matter, and that a clinic cannot infer real-use durability from a thickness figure alone. The correct reading of the 4.5 mil choice is that it buys handling comfort and a longer usable interval in wet work, while the barrier discipline still comes from changing the pair when it is contaminated, torn, or has been worn for an extended period.
How many cases should a busy clinic hold?
Work from encounters and from the change rate, not from a per-clinician average. This glove is used for the long and wet part of the day, so the number of pairs consumed is driven by how many of those appointments the practice runs rather than by total patient count.
| Usage shape | Long wet encounters per day | Pairs per encounter (with one change) | Gloves per 21-day month | Cases at 1,000 |
|---|---|---|---|---|
| One clinician, 4 wet procedures | 4 | 2 | 336 | 0.34 |
| Two clinicians, 10 wet procedures | 10 | 2 | 840 | 0.84 |
| Two chairs, 16 wet procedures | 16 | 2 | 1,344 | 1.34 |
| Three chairs, 24 wet procedures | 24 | 2 | 2,016 | 2.02 |
Most practices do not run a case of 4.5 mil on its own; they run the 3.2 or 4.0 mil as the everyday glove and keep one or two cases of the heavier film for the wet list. That pattern is why the thickness comparison collection exists — buying two weights deliberately costs less than buying the heaviest weight for every task.
What does the listing mean by medical grade, and what should a purchaser check?
Medical grade means the glove is an examination glove made to the nitrile glove specification, ASTM D6319, rather than a utility or food-service glove. Under the US framework the device is regulated by 21 CFR 880.6250 as a Class I non-powdered patient examination glove, and the exemption in that section covers finger cots only — an examination glove is expected to trace to a premarket notification. The classic purchasing error in this category is to read "Class I" as "no clearance required" and accept an unclassified import.
The second check is the standard reference on the box and the specification sheet: ASTM D6319 for the glove itself, with the manufacturer's watertightness sampling behind it. The third is the packing, because a case of ten boxes of 100 gloves carries one size only, and a team spread across S to XL needs the size split settled before the order rather than after it.
How should gloves be stored and dispensed?
Nitrile film degrades with heat, sunlight and ozone, so cases belong on a shelf in a dry room rather than beside a steriliser, an autoclave or a window. Keep the dispenser boxes closed and pull gloves one at a time; a box left open on a counter collects dust and is handled by everyone who walks past. Rotate stock so the oldest case is opened first. And keep the change rule visible at the chair: gloves are replaced when contaminated, torn or punctured, and hand hygiene comes before the pair goes on and after it comes off, because a glove is a barrier and not a substitute for washing hands.
What should a US buyer confirm before reordering?
Confirm the clearance reference for the device, the specification the glove is made to, the size split, and the case configuration of ten boxes of 100. Confirm too whether the practice intends this glove as the everyday glove or as the heavy-weight glove for the wet list, because the answer changes the case count. Freight and duties for United States addresses are shown at checkout. For a multi-site group or a long-term-care contract, the institutional account enquiry is the route to a written quotation that confirms sizes, quantities and delivery addresses.
Sources, checked 2026-11-21
- ASTM D6319-19 — Standard Specification for Nitrile Examination Gloves for Medical Application
- 21 CFR 880.6250 — Non-powdered patient examination glove (Class I; finger cot exemption)
- 29 CFR 1910.1030(d)(3)(ix) — Gloves: when required, when replaced
- OSHA Bloodborne Pathogens standard, 1910.1030
- Durability of examination gloves used on intensive care units (BMC Infect Dis, 2013)
- Integrity of disposable nitrile exam gloves exposed to simulated movement (2011)
- Improper glove use increases infection risk (Antimicrob Resist Infect Control, 2025)
- Glove permeation of chemicals: state of the art, part 2 (2020)
- ASTM D6978-05(2019) — Resistance of Medical Gloves to Permeation by Chemotherapy Drugs
- WHO Guidelines on Hand Hygiene in Health Care
Packing and what is included
1,000 gloves per case, as ten dispenser boxes of 100, in sizes S, M, L and XL, blue, powder-free and latex-free, with a fully micro-textured finish. The case carries one size only. Related reading: the 3.2, 4.0 and 4.5 mil comparison, the 4.0 mil Protégé glove, the 3.2 mil Transform 100 glove, and what to verify in a nitrile exam glove supplier. To size a month against your own wet-procedure count, use the clinic supply and cost planner; for a multi-site or institutional quotation, open an institutional account enquiry.
Common questions
Is it shipped from Canada?
Yes — orders ship from our Toronto warehouse.
How many cases does a small clinic use per month?
Depends on chair count and patient volume — the page spec table gives the case pack size so you can size an order against your own monthly usage.