Aurelia Face Mask — ASTM Level 3, Made in Canada, 50 per Box or 500 per Case
Ships to the US · US$9.99 flat, free over $300
Specifications
| Pack | 50 masks per box |
|---|---|
| Case of 10 boxes | 500 |
| Test standard | ASTM F2100, Level 3 |
| SKU | AUR-MASK-L3-BLU-CASE |
| Brand | Supermax Healthcare Canada (Aurelia) |
| Category | Face Protection |
| Availability | In stock |
Pricing
| Order | Unit price |
|---|---|
| 1 box | $49.70 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 10 sections · specs, use, compliance
This is an ASTM F2100 Level 3 ear-loop procedure mask made in Canada and sold 50 masks to a sealed box or 500 to a case, rated to 160 mmHg of synthetic blood, and it is the level to stock for surgical extractions with irrigation and full-mouth ultrasonic scaling where fluid arrives in volume.

What does ASTM F2100 Level 3 actually require of a face mask?
ASTM F2100 is the specification that classifies medical face mask material performance, and it addresses both tied masks and ear-loop masks in its scope. The standard sorts material into three levels by five tests: bacterial filtration efficiency (BFE), sub-micron particulate filtration efficiency (PFE) at 0.1 micrometre, differential pressure as a breathability measure, resistance to penetration by synthetic blood under pressure, and flame spread. Level 3 is the highest of the three levels, and the difference between a Level 2 and a Level 3 mask is not the fit or the shape — it is the measured resistance to synthetic blood under pressure, 160 mmHg against 120 mmHg.
The figure a buyer should ask for is not the word "Level 3" on its own but the test report behind it. On this mask the BFE and PFE results are recorded at or above 98% in a Nelson Labs report, PRB22172-SUP01, and that report number is the document a facility puts in its file when an auditor or a purchaser asks how the filtration claim was evidenced. The mask is built from three layers with a melt-blown middle layer between the inner and outer spun-bond layers, and the melt-blown middle is the layer doing the filtering.

How do Level 1, Level 2 and Level 3 differ in practice?
The three levels share the same test methods and the same flame-spread requirement, so the comparison is narrow and worth memorising as a single table. Level 1 is the general-examination level, Level 2 covers procedures where splashing is expected without much force, and Level 3 is for procedures where fluid arrives in volume or is projected. A procurement mistake usually comes from treating the three levels as interchangeable rather than as three different barrier ratings.
| Test (ASTM method) | Level 1 | Level 2 | Level 3 |
|---|---|---|---|
| Bacterial filtration efficiency, % (F2101) | ≥ 95 | ≥ 98 | ≥ 98 |
| Sub-micron particulate filtration, % at 0.1 µm (F2299) | ≥ 95 | ≥ 98 | ≥ 98 |
| Differential pressure, mm H₂O/cm² (F2100 §7) | < 5.0 | < 6.0 | < 6.0 |
| Synthetic blood resistance, mmHg (F1862) | 80 | 120 | 160 |
| Flame spread | Class 1 | Class 1 | Class 1 |
The same thresholds are reproduced in the Canadian federal procurement documentation that references ASTM F2100-19 for medical face masks, which is useful when a clinic works to both a Canadian and an American purchasing template and needs one table that satisfies both.
Which appointments need Level 3 instead of Level 2?
Start from the procedure, not from the price band. The exposure question is how much fluid the appointment produces and whether it is produced under pressure. Restorative work with a slow handpiece, sealant placement and most hygiene appointments generate splash; surgical extractions with irrigation, ultrasonic scaling through a full mouth, and any appointment where a high-volume irrigant is driven into the field generate fluid in volume, sometimes with force. Those are the appointments that justify Level 3, and they are the reason a practice that runs both types keeps two levels rather than one.
| Appointment type | Fluid volume and force | Level to stock | Why that level |
|---|---|---|---|
| Reception, triage, general examination | Low, no projection | Level 1 | Barrier against droplets at conversational distance |
| Sealants, simple restorative, slow handpiece | Moderate splash | Level 2 | Splash without sustained pressure |
| Simple extraction without irrigation | Moderate, brief | Level 2 | Blood contact, limited volume |
| Surgical extraction with irrigation | High volume, some force | Level 3 | 160 mmHg synthetic blood resistance |
| Full-mouth ultrasonic scaling | High volume, aerosolised | Level 3 | Fluid arrives continuously through the appointment |
| Long-term care, feeding and oral care rounds | Variable, often unplanned | Level 2 or 3 | Stock the level the highest-exposure task needs |
What does the ear-loop format change, and when is a tie-on mask the better choice?
ASTM F2100 covers both tied masks and ear-loop masks, so an ear-loop mask is not a lesser category — it is a different retention method. Ear loops are faster to put on and take off, which matters in a clinic running short appointment blocks and in long-term care where staff don masks repeatedly through a shift. Tie-on masks allow the tension to be set at the back of the head and are usually preferred for long surgical cases where loop pressure behind the ears becomes uncomfortable after an hour. The adjustable nose bridge on this mask is what keeps the upper edge closed over the bridge of the nose; a mask that gaps there leaks unfiltered air at the eyes and fogs loupes.
The published fit literature is consistent on one point: filtration efficiency measured on flat material is not the same as protection on a face. Work on medical procedure masks shows that fit at the edges drives how much unfiltered air bypasses the filter, and that improving the seal at the edges changes performance measurably without changing the mask's rating. That is why the nose bridge and the loop tension matter as much as the Level 3 label, and why a mask that is comfortable enough to leave in place all day performs better than a higher-rated mask that the wearer pushes down.
How many masks does a clinic use in a month?
Count one mask per clinician per appointment block, not one per patient, and add the masks used for fit checks, drop-ins and remakes. The formula is blocks per day × clinicians × working days, and the answer in boxes follows by dividing by 50. A single-chair practice with 12 blocks a day over 21 working days works out to about 250 masks, which is five boxes or half a case. Two clinicians running 20 blocks a day land at roughly 420 masks, which is where the case of 500 starts to make sense.
| Setting | Blocks per day | Masks per working day | Masks per 21-day month | 50-mask boxes |
|---|---|---|---|---|
| Single chair, one clinician | 12 | 12 | 252 | 5.0 |
| Two clinicians, shared chair | 18 | 18 | 378 | 7.6 |
| Two chairs, dentist and hygienist | 20 | 20 | 420 | 8.4 |
| Three chairs, full day | 30 | 30 | 630 | 12.6 |
| LTC unit, eight care staff on rounds | 4 rounds | 32 | 672 | 13.4 |
Two adjustments are worth making to that arithmetic. First, a clinic that changes masks between every patient as well as between blocks runs 15 to 25% higher than the table. Second, a practice that stocks both Level 2 and Level 3 should split the monthly estimate by procedure mix rather than dividing it in half — a hygiene-heavy book consumes more Level 3 than a restorative-heavy one.
What goes wrong when the wrong level is stocked?
The failure is quiet. A Level 2 mask does not announce that it is the wrong choice during a surgical extraction with irrigation; it wicks, and the wearer notices dampness at the edges of the mask after the appointment rather than during it. In an occupational health inspection the question is not what the box said but whether the employer selected PPE on the basis of anticipated exposure — the US Bloodborne Pathogens standard requires masks in combination with eye protection whenever splashes, spray, spatter or droplets of blood or other potentially infectious material may be generated and eye, nose or mouth contamination can be reasonably anticipated. A clinic that stocks a single mid-level mask and uses it for every procedure has to explain, in writing, why the highest-exposure procedure on its list was covered by a lower barrier rating.
The second failure mode is documentation. When a purchaser or an accreditation reviewer asks how a filtration claim is supported, the answer has to be a test report, not a product category. Keeping the Nelson Labs report number for each level stocked, and matching it to the boxes on the shelf, is the difference between a claim and a record. The third is fit: a Level 3 mask worn with a gap at the nose bridge is not delivering Level 3 filtration to the wearer, so the adjustable bridge should be set before the first patient rather than after the first fogged loupe.
What should a US buyer confirm before reordering?
Three things are worth confirming in writing. The first is the classification: in the United States a surgical mask falls under 21 CFR 878.4040 as surgical apparel, Class II with special controls, and the product code FXX requires premarket notification, so the mask on the shelf should trace to a cleared device rather than an unclassified import. The second is the level and the report number, both of which should appear on the box, because the ASTM F2100 table is a performance claim that has to be evidenced per lot. The third is the packing: this listing is 50 masks per sealed box and 10 boxes per case, and the case is the unit that makes pallet and shelf planning predictable.
Freight and duties for United States addresses are shown at checkout rather than built into a landed price, so a purchasing officer can see the delivered cost before approving the order. For a multi-site group, a purchase order covering several facilities, or a long-term-care contract, the institutional account enquiry page is the route to a written quotation with the case quantities and the delivery schedule confirmed for each address.
How is the Level 3 mask stored and handled between cases?
Masks are single-use items: they are removed and discarded when soiled, damp or damaged, and they are not reprocessed. Storage matters more than most clinics expect, because a box left open on a counter picks up dust and moisture, and a mask that has been folded into a pocket has lost the shape of its nose bridge. Keep the boxes closed on a shelf away from sinks and sterilisation areas, and count a mask that has been worn for a procedure as finished. For long-term-care units where masks are donned and doffed many times per shift, hand hygiene before and after handling a mask is the control that the published glove and mask literature keeps returning to.
Sources, checked 2026-11-21
- ASTM F2100-21 — Standard Specification for Performance of Materials Used in Medical Face Masks
- FDA Recognized Consensus Standard, FR Recognition Number 6-492 (ASTM F2100)
- 21 CFR 878.4040 — Surgical apparel (Class II, special controls)
- 29 CFR 1910.1030(d)(3)(x) — Masks, eye protection and face shields
- OSHA Bloodborne Pathogens standard, 1910.1030
- CanadaBuys procurement specification — medical face mask requirements, ASTM F2100-19 table
- Maximizing Fit for Cloth and Medical Procedure Masks (MMWR, 2021)
- Design elements in face masks that provide an effective fit
- 3D modelling of particle dispersion with and without a mask, Scientific Reports (2023)
- WHO Guidelines on Hand Hygiene in Health Care
Packing and what is included
One sealed box holds 50 masks; a case holds 10 boxes, 500 masks. The box is available in Blue and in Pink Rose, and the ASTM F2100 Level 3 rating and the Nelson Labs report apply to the mask, not to the colour. The mask is manufactured in Canada with a three-layer construction, soft ear loops and an adjustable nose bridge. Related reading on this site: the ASTM Level 2 mask in the same range, case quantities and par levels for dental clinics, the nose clip, fit and fogging, and the full face mask and PPE range. To estimate a month against your own appointment count, use the clinic supply and cost planner; for a multi-site or institutional quotation, open an institutional account enquiry.
Common questions
What does Level 3 add over Level 2 on an ASTM F2100 mask?
Both levels carry the same F2100 test standard and the same fit; what separates them is measured fluid resistance. Level 2 covers blood-splash procedures, and Level 3 is where more fluid is expected, such as surgical and heavily irrigated hygiene work.
What filtration efficiency was measured on this Level 3 mask?
BFE and PFE at or above 98%, recorded at Nelson Labs under report PRB22172-SUP01, on a 3-layer construction with a melt-blown middle layer, soft ear loops and an adjustable nose bridge.
Which dental appointments call for the Level 3 mask?
Surgical appointments and hygiene appointments with heavy irrigation, including an ultrasonic scaler running through a full mouth. Restorative work with a slow handpiece and simple extractions sit at Level 2 instead.
Which colours does the Level 3 listing come in, and does the level change?
Blue and pink rose, in boxes of 50 masks. The ASTM F2100 Level 3 rating and the Nelson Labs report PRB22172-SUP01 apply to the mask itself, so the colour choice does not change the measured performance.
How should domestic sourcing be documented for these masks?
The masks are manufactured in Canada and tested to ASTM F2100 Level 3 at Nelson Labs, report PRB22172-SUP01, with BFE and PFE at or above 98%. CliniEco Medical distributes the range in Canada under MDEL #35334.
Should a mask be counted per patient or per appointment block?
Count 1 mask per staff member per appointment block, not 1 per patient. A 2-chair practice with 2 hygienists and 1 dentist running 20 blocks a day gets through 60 to 80 masks a day, which is 1,250 to 1,700 over 21 working days.