The scar follow-up clinic has a counting problem that no other consumable in the building shares: nothing is used in the building. A tube of CliniEco Medical silicone scar gel, 15 g, supplied as a two-tube pack is handed to a patient at the end of an appointment and disappears into a bathroom cabinet for the length of a course. The shelf empties while the treatment room looks untouched, and a count kept in the treatment room will report full stock on the day the clinic runs out.
Silicone scar gel is used on closed, healed skin to manage the appearance of hypertrophic and keloid scars, in a thin layer twice a day for sixty to ninety days. That course length is what makes the par level unusual. A clinic is not restocking a consumable it burns through in a week; it is keeping a queue of sixty-day courses supplied, and the count has to be kept where the stock is actually consumed - at the point of dispensing.
This guide covers the counting unit, the weekly count itself, the arithmetic that turns four weeks of dispensing into a reorder point, and the two things a Canadian buyer has to keep on the stock record: the lot, and the evidence that the product is the device it claims to be on both sides of the border.
A scar gel par level, in six points
- Count tubes dispensed, not tubes visible: the product leaves the building, so the stock record belongs at the dispensing point.
- A 15 g tube is sized to one scar for a 60 to 90 day course at two applications a day; a wide abdominal scar can take a second tube.
- The listing is supplied as a two-tube pack, which reads as one course plus one spare, so the count runs in tubes and orders in packs.
- In the United States the product family sits under Class I product codes for silicone scar management, filing under 21 CFR 878.4025 and exempt from premarket notification.
- In Canada the article is a device, and the distributor's establishment licence is the number a clinic can verify - this catalogue is distributed under MDEL #35334.
- The lot number belongs on the dispensing record as well as the shelf label, because the patient, not the clinic, holds the tube when a question comes back.

The counting unit follows the pack, and the pack is deliberately small. Fifteen grams at two applications a day covers one scar through a typical course; a second tube is used when the scar is wide or the course runs to the far end of the label range. A clinic that counts in packs therefore counts in units of two courses at the narrow end and one course at the wide end, which is too coarse for a reorder point, so the count is kept in tubes and only the order is rounded to packs.

What is a par level for silicone scar gel?
A par level is the quantity that has to be in the cupboard on count day to keep every patient already in a course supplied until the next delivery lands, plus a margin for the count being wrong. For a product that is dispensed rather than consumed on site, the quantity is driven by the number of courses running at once, not by the number of patients seen in a week, because a patient seen once holds a tube for two to three months.
The distinction matters at the point where a clinic starts a new aesthetic or post-surgical service. A clinic that begins offering scar follow-up to twenty patients a month is not drawing twenty tubes a month: it is starting twenty courses, each of which consumes one or two tubes over the course, and the shelf has to carry the courses that are already running. That is why the par is set from the number of courses started per week and the course length, not from the appointment count.
How do I count scar gel at the weekly count?
Count sealed tubes in the cupboard and add the tubes already issued but not yet finished - which, for a product that leaves the building, means the count of courses running. A working convention is to hold one issued tube per active course as a committed unit and to count only the sealed stock as available, so the sheet has two columns: committed and on shelf. A clinic that cannot see the issued tubes from the cupboard can still get the figure from the dispensing record, which is why the record and the count are one procedure rather than two.
Count weekly, on the same day, and write the count against the treatment list for that week. The draw is then the number of tubes that left the cupboard in the seven days, adjusted for any pack opened mid-week. A clinic that dispenses from an unopened pack without recording it will find its count drifting by one pack a month, which at a two-tube pack is enough to hide a stockout for a fortnight.
How do I turn a week of dispensing into a reorder point?
Measure the draw in tubes over four consecutive weeks. A clinic starting four courses a week, at an average of one and a quarter tubes per course, is drawing five tubes a week; the quarter reflects the wide scars and the longer courses, and it is measured rather than assumed. Five tubes a week is two and a half packs a week, which is the number the order conversation actually uses.
With a one-week lead time, a one-week review period and one week of safety, the par is fifteen tubes - three weeks of draw - which is seven and a half packs, rounded to eight packs. Eight packs is sixteen tubes, so the order trigger sits at fifteen tubes on the shelf and the delivery leaves a single tube of headroom. A clinic that rounds the par up to ten packs is carrying a month of supply for a product with a long shelf life, which is defensible; a clinic that rounds the trigger down to six packs is one busy week away from splitting a pack.
| Courses started a week | Tubes per course (measured) | Tubes a week | Par in tubes (3 weeks) | Par in two-tube packs |
|---|---|---|---|---|
| 2 | 1.25 | 2.5 | 8 (round to 8) | 4 |
| 4 | 1.25 | 5 | 15 | 8 |
| 6 | 1.4 | 8.4 | 25 | 13 |
The third row is the one that catches clinics out. A site that moves from four to six courses a week, and whose scars are on average wider, does not move the par from fifteen to twenty-two; it moves it to twenty-five, because both the course count and the tubes per course have changed. Recomputing from the two measured inputs is faster than arguing about the old number.
How do the Canadian and American rules change what the stock record has to show?
On both sides of the border the product sits in the same regulatory category, and the paperwork around it does not. Queried through the openFDA device classification database on 24 November 2026, the product codes that cover silicone scar management are Class I and both file under 21 CFR 878.4025, the section titled silicone sheeting; that section exempts the devices from premarket notification, so there is no clearance number for a buyer to look up. In Canada the article is a device regulated under the Medical Devices Regulations, and the number a clinic can actually verify belongs to the distributor: the establishment licence, held by the importer or distributor that places the device on the market.
What separates the two markets for a buyer is not the classification but the trail. A Canadian clinic can ask for the MDEL number and match it to the seller; an American clinic can ask for the product code and the regulation number and match them to the classification database; neither clinic gets a per-unit licence document, because the category does not issue one. The biological evaluation behind the material - ISO 10993-1 as the framework, with cytotoxicity and skin sensitization testing under parts 5 and 10 - is the file that answers a clinician's question about what touches the scar, and a supplier who cannot name those tests is answering a different question.
| Item | Canada | United States |
|---|---|---|
| Regulatory route | Device under the Medical Devices Regulations; distributor holds an establishment licence | Class I device, exempt from premarket notification |
| Number a clinic can verify | MDEL of the importer or distributor, for example MDEL #35334 | Product code and regulation number, 21 CFR 878.4025 |
| Quality system evidence | ISO 13485 certificate from the manufacturer | 21 CFR Part 820 compliance from the manufacturer |
| Label content | Device label with the lot and the indications in the market's required languages | Label meeting 21 CFR Part 801, English |
| Record the count supports | Distribution record plus clinic dispensing log | Distribution record plus clinic dispensing log |
The last row is identical on purpose. The par level and the record it produces are the clinic's own control, and no regulator on either side prescribes what a scar gel count sheet must contain. What the two systems do prescribe is what the supplier has to be able to show, which is why the vendor file and the stock sheet are worth keeping in the same folder.
What should the dispensing record carry?
Six fields per issue: date, patient file number, scar site, tube count, lot number and the name of the clinician who dispensed it. The lot number is the field most often left blank and the one that matters first, because a tube handed to a patient cannot be recalled from the cupboard - it can only be traced, and tracing needs the lot on the record. The site field is what makes the count auditable: a clinic that sees a wide abdominal scar and a short facial scar as the same issue will under-forecast the tubes per course by a third.
Two more fields belong on the sheet when the clinic is also supplying reusable silicone scar sheeting for the same patients. The sheet is a different device with a different use pattern - washed and reused rather than consumed - so it needs its own par and its own record, and mixing the two products in one count produces a number that describes neither. Where a patient switches between gel and sheet mid-course, the dispensing record should show the switch, because the course then draws down two stock lines.
When should the par level change?
Four events. A new surgeon or dermatologist referring scar follow-up increases the number of courses started, which is the input that matters. A change in the referral mix toward wider scars raises the tubes per course, and that is a second, separate change to the same number. A switch from gel to sheeting for part of the caseload moves draw between two stock lines and should be reflected in both pars the same week. The fourth event is the pack change itself: if the supplier moves from a two-tube pack to a single-tube unit, the par in tubes stays the same and the par in packs halves, which is exactly the kind of translation error a written formula prevents.
Where a clinic runs the arithmetic once and reuses it, the supply planning worksheet takes the courses started and the course length and returns the par in tubes, and the same page carries the supply planner for sites running several consumables on one count. Account and volume questions go through the institutional and wholesale account enquiry, and the product page lists the pack build so that the count and the order use the same unit. Reselling? become a distributor.
References
- Medical Devices Regulations, SOR/98-282, labelling sections 21 to 23 - checked 24 November 2026.
- Health Canada, medical devices: device classes, regulatory guidance and establishment information - checked 24 November 2026.
- Health Canada, establishment licences for medical device importers and distributors, including the MDEL requirement - checked 24 November 2026.
- Health Canada, medical device guidance documents index - checked 24 November 2026.
- US Food and Drug Administration, openFDA device classification API, queried for the loupe product codes listed in this article - checked 24 November 2026.
- 21 CFR 878.4025, silicone sheeting, Class I, exempt from premarket notification subject to 878.9 - checked 24 November 2026.
- ISO 13485:2016, medical devices, quality management systems - checked 24 November 2026.
- ISO 14971:2019, medical devices, application of risk management - checked 24 November 2026.
- ISO 10993-1:2018, biological evaluation of medical devices, evaluation and testing within a risk management process - checked 24 November 2026.
- ISO 10993-5:2009, biological evaluation of medical devices, in vitro cytotoxicity tests - checked 24 November 2026.
- ISO 10993-10:2021, biological evaluation of medical devices, tests for skin sensitization - checked 24 November 2026.
- ISO 17664-1:2021, processing of health care products, information to be provided by the medical device manufacturer for the processing of medical devices - checked 24 November 2026.
- 21 CFR Part 820, quality system regulation for medical devices placed on the US market - checked 24 November 2026.
- 21 CFR Part 801, labelling requirements for medical devices in the United States - checked 24 November 2026.
- Canadian Centre for Occupational Health and Safety, hand protection and glove selection - checked 24 November 2026.
Related Reading
- Lot number documentation for silicone scar gel in Canadian clinics
- How many tubes of silicone scar gel one patient uses
- Silicone scar gel after laser treatment in Canadian aesthetic clinics
Frequently Asked Questions
How often should a scar gel count be done?
Weekly, on the same day as the treatment list. A weekly count matches the review period in the par calculation and picks up the packs opened mid-week before the drift becomes a stockout.
Should the tubes already handed to patients be counted?
They are recorded as committed units, not as available stock. The count that drives the order is the sealed stock, and the committed figure tells the clinic how fast that stock will be drawn down over the coming weeks.
Is a 15 g tube enough for one course?
For one scar at a thin layer twice a day over sixty to ninety days, yes; a wide or long scar can take a second tube. That is why the arithmetic uses a measured tubes-per-course figure rather than a whole number.
Does the par change if the clinic also stocks silicone sheeting?
It changes both pars. Sheeting is washed and reused rather than dispensed and consumed, so it has a different draw pattern and its own count line; a patient who switches products mid-course draws on both.
What licence should a Canadian clinic ask for?
The establishment licence of the importer or distributor, which is an MDEL. This catalogue is distributed under MDEL #35334. The category does not issue a per-unit device licence in either country.
What does the US classification show for this product family?
The codes covering silicone scar management are Class I and file under 21 CFR 878.4025, exempt from premarket notification, which is why a US buyer is given a product code rather than a clearance number.
Figures in this article are planning and troubleshooting references, not clinical, legal or regulatory advice, and they do not replace the sterilizer or washer-disinfector manufacturer's instructions for use. Requirements quoted here were published as described at the time of writing and are amended from time to time, so confirm them against the instruments in force for your jurisdiction. CliniEco Medical distributes medical consumables under MDEL #35334.