A five-chair practice that does its own surgery keeps two very different weeks inside the same seven days. On a hygiene day an HVE tip is picked up, used once and dropped; on a surgical day the tip is changed between phases of the same appointment, and a single extraction with a graft can draw three. The Aurelia HVE tips, white, vented, 100 tips per bag are the same consumable in both weeks, which is exactly why a count that averages them will be wrong twice.
High-volume evacuation is the part of the suction set that carries the aerosol, and that changes what the count is protecting. A practice can finish a hygien appointment with a handpiece and no suction if it has to; it cannot run an aerosol-generating procedure without high-volume evacuation, because the suction is the control, not the convenience. Running out mid-list is not an inconvenience in that operatory, it is a stop-work condition.
This guide sets out the counting unit, a count that separates hygiene days from surgical days, the arithmetic that turns the count into a reorder point in bags, and the two documents a Canadian clinic and an American clinic are each asked to keep on file for a single-use tip.
An HVE tip par level, in six points
- Count bags, and count them separately for hygiene days and surgical days, because the tips per appointment differ by a factor of two.
- A surgical appointment can draw two or three tips - one per phase, plus a replacement when a tip is blocked - so the draw is not the patient count.
- Set the par as the weekly draw multiplied by lead time plus one review week, plus one week of safety, then round to whole bags, counting in bags and ordering in whole 10-bag cases.
- In the United States the oral cavity evacuator is a Class I device, exempt from premarket notification, under the dental operative unit and accessories regulation.
- In Canada the tip is a device sold by a licensed establishment; this catalogue is distributed under MDEL #35334.
- The vent pattern and the connector are part of the par conversation, because a tip that does not fit the valve is stock the clinic cannot use.

The bag holds one hundred tips, so the counting unit is the bag for the same reason it is for a saliva ejector: a hundred is a week or two of stock, which is the right size for a count taken every seven days. What differs is the spread between days. A practice that counts once a week and does not split hygiene from surgery will see a number that jumps whenever a surgical list lands in the count period, and will spend the next month arguing with the average.

What is a par level for high-volume evacuator tips?
A par level is the quantity that has to be in the operatory cupboard on count day to run every scheduled list to the next delivery, plus a margin for the count being wrong and for a list that turns out heavier than booked. For a single-use tip the draw tracks the procedures, and the procedures are what the count has to capture, which is why an HVE par is closer to a small production plan than to a stock check.
The margin deserves its own line. An HVE tip that is dropped, blocked or will not seat properly in the valve is replaced mid-appointment rather than retrieved, so the draw always runs a little above the number of tips that did the work. Measuring that gap over four weeks is more reliable than adding a percentage, because the gap moves with the surgical share: a practice that adds implant cases will see it widen before it sees the patient count move.
How do I count HVE tips across hygiene and surgical days?
Count sealed bags in each operatory and in the main store, and count an opened bag as a fraction. Keep two rows on the sheet for a mixed practice: hygiene operatories and surgical operatories. The two rows are not a complication; they are the whole reason the count works, because they draw at different rates and they are drawn down from the same stock.
Take the count on the same day each week, and note on the sheet whether a surgical list ran in that seven-day window. That single note is what turns four weekly numbers into a usable series: a week with a list and a week without are not comparable, and a count that treats them as comparable will set the par too low in the surgical months and too high in the quiet ones.
How many tips does a surgical day consume?
The figure that matters is tips per appointment, and it is measured rather than assumed. In a practice doing routine hygiene and restorative work with a surgical list once a week, the draw lands near one tip per appointment on hygiene days and between one and a half and three on surgical days, depending on how the appointment is staged. For a five-chair practice running 500 appointments a week, with surgical work at eight per cent of appointments and an average of 1.8 tips on those, the weekly draw works out to roughly 482 tips - near enough to five bags.
| Practice shape | Appointments a week | Surgical share | Tips a week | Bags a week |
|---|---|---|---|---|
| Two chairs, hygiene and restorative | 220 | 2% | 230 | 2.3 |
| Five chairs with one surgical list | 500 | 8% | 482 | 4.8 |
| Six chairs, surgical heavy | 600 | 15% | 732 | 7.3 |
Reading the table the wrong way round produces the common error. A practice that sees the six-chair row and buys a fixed quantity on the strength of the appointment count will hold two weeks of stock at four bags a week and four days of stock at seven; the appointment count barely moves between those two practices, but the tip count nearly triples. The surgical share, not the chair count, is the input that has to be measured.
How do I convert four weeks of counts into a reorder point?
Average the draw over four weeks in bags, having noted which weeks carried a surgical list. At five bags a week, with a one-week lead time, a one-week review period and one week of safety, the par is fifteen bags - three weeks of draw. A trigger at fifteen bags is answered by ordering the par in full, and because the tips ship ten bags to a case, fifteen bags rounds up to two 10-bag cases - twenty bags, which is 1,000 tips to the case. The shelf then holds thirty-five bags after delivery, seven weeks at this draw, and the next trigger arrives four weeks later.
A surgical-heavy practice should treat the safety week as a safety list rather than a safety week. At seven bags a week the par of twenty-one bags is three weeks of stock, and an order that answers the trigger only in part leaves the shelf below the par - so the next count triggers again immediately, and the order rhythm collapses to an order every week. Ordering the full par is not over-buying; it is the quantity the arithmetic implies once the trigger is respected. In case terms twenty-one bags is three 10-bag cases - thirty bags - because the order cannot be cut below a whole case.
How does the Canadian and American paperwork differ for a suction tip?
Both markets classify the article as low risk, and both expect single use. Queried through the openFDA device classification database on 24 November 2026, the oral cavity evacuator is a Class I device, exempt from premarket notification, filing under 21 CFR 872.6640 for a dental operative unit and its accessories. In Canada the tip sits under the Medical Devices Regulations, and the number a clinic verifies belongs to the seller: the establishment licence, with this catalogue distributed under MDEL #35334.
The difference a clinic feels is in the exposure control file. In the United States, high-volume evacuation is written into the practice's bloodborne pathogens exposure control plan, alongside the personal protective equipment the procedure requires, because the suction is part of how the aerosol is controlled for staff. In Canada the same practice writes the equivalent into its infection prevention and control manual, which is where the provincial dental guidance and the reprocessing instructions meet. Neither document asks for a certificate per bag; both expect the clinic to show that the routine exists, that staff follow it, and that the consumables needed for it are on hand.
| Item | Canada | United States |
|---|---|---|
| Regulatory route | Device under the Medical Devices Regulations, sold by a licensed establishment | Class I device, exempt from premarket notification |
| Number a clinic can verify | MDEL of the importer or distributor, for example MDEL #35334 | Product code and 21 CFR 872.6640 |
| Where aerosol control is written down | Provincial infection prevention and control guidance, adopted into the clinic manual | Bloodborne pathogens exposure control plan |
| Reprocessing information | Manufacturer's instructions under ISO 17664-1 where the item is reusable | Same standard, cited in the exposure control plan |
| Counting unit in practice | Bag of 100 | Bag of 100 |
The two files converge on the same practical question, which is whether the cupboard can support the list that is booked. That is what the par level answers, and it is why the count sheet belongs next to the exposure control plan rather than in a purchasing folder.
What should the count sheet record each week?
Date, location, sealed bags, fraction of the open bag, total in bags, whether a surgical list ran in the period, and the lot on the case behind the stock. When the count reaches the par, record the quantity ordered and the date ordered. At the foot of the sheet, two lines: the par in bags and the measured draw excluding surgical weeks, so the two rhythms stay visible.
The other suction line runs on exactly this sheet. Aurelia saliva ejectors, white, 100 per bag are counted in bags and bought in the same 10-bag case, so a practice that stocks both can keep one par method and two product lines.
The vent and connector columns are worth adding for a practice that stocks more than one style. An HVE tip that does not match the valve is not stock, and a count that mixes vent patterns will report a comfortable total while one chair has nothing that fits it. Writing the style on the sheet costs a column and prevents a mid-list search of the store cupboard.
When should the par level change?
Adding a surgical list is the first event, and it can double the draw without changing the appointment count. Adding a chair is the second. Changing the tip style, or the evacuation system, is the third, because either change resets what counts as usable stock. The fourth is a change in the practice's aerosol protocol: a move to more high-volume evacuation, or a decision to change tips between phases where the practice previously did not, shows up in the draw before it shows up anywhere else.
Where a practice wants one sheet to serve both rhythms, the dental clinic supply range lists the pack sizes alongside the vent style, so the count and the order use the same description. Multi-site groups set accounts up through the institutional and wholesale account enquiry, the compliance log centre carries the printable log generator for the weekly count, and aerosol and suction routines can be checked against the clinic's own manual through the sterilization and infection control consultation route. Reselling? become a distributor.
References
- 21 CFR 872.6640, dental operative unit and accessories, Class I, accessories exempt from premarket notification - checked 24 November 2026.
- US Food and Drug Administration, openFDA device classification API, queried for the loupe product codes listed in this article - checked 24 November 2026.
- Medical Devices Regulations, SOR/98-282, labelling sections 21 to 23 - checked 24 November 2026.
- Health Canada, medical devices: device classes, regulatory guidance and establishment information - checked 24 November 2026.
- Health Canada, establishment licences for medical device importers and distributors, including the MDEL requirement - checked 24 November 2026.
- Health Canada, medical device guidance documents index - checked 24 November 2026.
- US Centers for Disease Control and Prevention, Guidelines for Infection Control in Dental Health-Care Settings, MMWR 2003;52(RR-17), sterilization monitoring section - checked 24 November 2026.
- Public Health Ontario, infection prevention and control dental checklist, core elements - checked 24 November 2026.
- Royal College of Dental Surgeons of Ontario, Standard of Practice: Infection Prevention and Control, version 3, including the sterilization monitoring and load release sections - checked 24 November 2026.
- ISO 17664-1:2021, processing of health care products, information to be provided by the medical device manufacturer for the processing of medical devices - checked 24 November 2026.
- US Occupational Safety and Health Administration, bloodborne pathogens standard, 29 CFR 1910.1030 - checked 24 November 2026.
- 29 CFR 1910.1030, bloodborne pathogens, including sharps and personal protective equipment requirements - checked 24 November 2026.
- Canadian Centre for Occupational Health and Safety, biological hazards answers, including blood-borne pathogens - checked 24 November 2026.
- Occupational Health and Safety Act, R.S.O. 1990, c. O.1 - checked 24 November 2026.
- Public Health Ontario, routine practices and additional precautions in all health care settings - checked 24 November 2026.
Related Reading
- Dental suction and HVE: which class in Canada and the United States
- Weak suction: is it the tip, the valve or the line?
- How many saliva ejectors and HVE tips an American dental clinic uses a day
Frequently Asked Questions
How often should the HVE tip count be done?
Weekly, with a note on the sheet saying whether a surgical list ran that week. The note is what makes four weekly counts comparable, because a week with a list draws at a different rate from a hygiene week.
How many tips does one surgical appointment use?
Between one and a half and three in a practice that stages its surgical work, because the tip is changed between phases and replaced when it is blocked or will not seat. Measure it in your own practice rather than taking a national average.
Should the open bag be counted as a full bag?
No. Count the fraction left. An opened bag is the one that will run out mid-list, and treating it as full is the most common way a practice discovers a shortage during a surgical appointment.
Are HVE tips sterile?
They are supplied clean for single use and are discarded after the appointment. The clinic's obligation is that a fresh tip is available for every procedure that needs high-volume evacuation, and that used tips go into the waste stream the practice has set up.
What does the US classification say?
The oral cavity evacuator is Class I, exempt from premarket notification, under 21 CFR 872.6640. A US buyer is given a product code rather than a clearance number.
What licence should a Canadian clinic verify?
The establishment licence of the importer or distributor, which is an MDEL. This catalogue is distributed under MDEL #35334. The category does not issue a per-unit licence.
Figures in this article are planning and troubleshooting references, not clinical, legal or regulatory advice, and they do not replace the sterilizer or washer-disinfector manufacturer's instructions for use. Requirements quoted here were published as described at the time of writing and are amended from time to time, so confirm them against the instruments in force for your jurisdiction. CliniEco Medical distributes medical consumables under MDEL #35334.