A glaucoma screening encounter consumes less material than a surgical case and more than a routine examination. The consumable stack is small and repeatable, which makes it easy to under-order: a chart card and an occluder, a tonometer prism or probe cover, a swab for the tear film, gloves, and the disinfection material that the lane uses between patients. What makes the count interesting is that the devices the consumables serve sit in three different American regulatory categories, and the rule for the tonometer tip is not written by the same agency that clears the tonometer.
The consumables that carry the encounter are an eye test chart set with Snellen and Amsler cards for acuity and macular screening, an eye patch occlusion set for monocular testing and post-procedure cover, and individually wrapped cotton swabs for the tear film and lid margin work that precedes applanation.
Quick facts for a per-encounter count in a screening lane
- An applanation tonometer is a Class II device in the United States under 21 CFR 886.1930, and the classification database shows a submission type that requires a premarket notification (21 CFR 886.1930, checked 20 November 2026).
- An AC-powered perimeter is a Class I device under 21 CFR 886.1605 and is exempt from premarket notification, which does not mean unregulated (21 CFR 886.1605, checked 20 November 2026).
- The CDC guideline lists applanation tonometers among semicritical items and points to FDA-cleared instructions for the liquid chemical sterilants or high-level disinfectants used on them (CDC, Disinfection of Healthcare Equipment, checked 20 November 2026).
- The same CDC section records two reports in which disinfection of pneumotonometer tips between uses with a 70% isopropyl alcohol wipe contributed to outbreaks of epidemic keratoconjunctivitis caused by adenovirus type 8.
- In Canada, a semi-critical device is reprocessed to the level CSA Z314:23 requires, and the 2023 edition revised that minimum level and the associated risk assessment (CSA Z314:23, checked 20 November 2026).
- The Canadian Ophthalmological Society guideline notes that up to 61% of patients with primary open-angle glaucoma have a single screening intraocular pressure below 21 mm Hg, so a pressure reading is not a screening result on its own.
What does one glaucoma screening encounter actually consume?
Five consumable groups repeat per patient. The first is identity and recording: a chart card, a near card and a disposable or wiped occluder, and the ink or label that ties the record to the patient. The second is the tear film and anaesthetic step, which consumes a swab and, where the clinic uses it, a fluorescein strip or unit-dose anaesthetic. The third is the tonometer interface, which is either a reusable prism that is reprocessed or a disposable cover or tip. The fourth is protective: gloves per patient, plus a mask where the clinic's policy requires one. The fifth is the disinfection material consumed between patients, which is invisible on a purchase order but is the line item most likely to run out during a busy screening list.
The count is small per patient, which is exactly why the reorder level should be built from patient volume rather than from historic order size. A lane that sees twenty screening patients in a morning consumes twenty pairs of gloves, twenty chart or occluder units if the occluder is single-use, and twenty disinfection events on the tonometer interface. A practice that orders on a monthly rhythm without knowing that number either carries excess or runs out mid-list.
| Consumable group | Unit of use | What fixes the per-encounter count |
|---|---|---|
| Chart card, near card and occluder | Per patient, single-use or wiped between patients | Acuity protocol and whether the occluder is disposable |
| Swab and fluorescein or anaesthetic unit-dose | Per eye, per encounter | Whether the clinic uses unit-dose or reusable delivery |
| Tonometer prism, tip or disposable cover | Per eye, per encounter | Device instructions for use and the reprocessing method the clinic validates |
| Gloves and any mask | Per patient contact | Clinic policy and the tasks performed in the encounter |
| Disinfection material | Per patient, per device touched | Which items contact the patient and which are barrier-protected |
Which device in the screening lane is regulated as Class II in the United States?
More than the equipment list suggests. The manual and AC-powered tonometers sit in 21 CFR 886.1930 as Class II, and the classification database shows a submission type that requires a premarket notification. The slit-lamp biomicroscope is 21 CFR 886.1850, also Class II, with the AC-powered code requiring a premarket notification while an exempt counterpart exists. The ophthalmoscope is 21 CFR 886.1570, Class II with an exemption for the common codes, and the perimeter is 21 CFR 886.1605, Class I and exempt. A dedicated tonometer sterilizer is separately classified at 21 CFR 886.1940 as Class I and exempt.
The practical point for a buyer is that exempt does not mean unregulated. An exempt device still has to be registered and listed, still carries labelling requirements, and still has to be used according to its cleared or exempt instructions. When a purchasing department asks whether a screening lane's perimeter needs a 510(k), the honest answer is that the device's product code and submission type decide it, not the price bracket or the vendor's description.
| Device | 21 CFR section | US class | Premarket notification |
|---|---|---|---|
| Manual tonometer | 886.1930 | Class II | Required for the code |
| AC-powered tonometer | 886.1930 | Class II | Required for the code |
| Slit-lamp biomicroscope | 886.1850 | Class II | Required for the AC-powered code; exempt counterpart exists |
| Ophthalmoscope | 886.1570 | Class II | Exempt for the common codes |
| AC-powered perimeter | 886.1605 | Class I | Exempt |
| Tonometer sterilizer | 886.1940 | Class I | Exempt |
What does the CDC require of the tonometer tip between patients?
The CDC guideline places applanation tonometers in the semicritical group, the items that contact mucous membranes or non-intact skin, and expects high-level disinfection at minimum. It then makes an observation that changes how a clinic should buy disinfection material: the optimal contact time for high-level disinfection has not been defined and varies among professional organisations, which produces different strategies for different semicritical items, and the guideline's advice is to follow its own recommendations together with FDA-cleared instructions for the liquid chemical sterilants or high-level disinfectants used.
The same section records a specific failure that every screening lane should know. Two reports found that disinfection of pneumotonometer tips between uses with a 70% isopropyl alcohol wipe contributed to outbreaks of epidemic keratoconjunctivitis caused by adenovirus type 8. The lesson is not that alcohol is useless; it is that a wipe is a contact-time-dependent process, and a quick pass over a tonometer tip is not the same operation as a validated disinfection step with a stated contact time. A clinic buying wipes by the case should also be buying the contact time from the product label and the device instructions.
How does the Canadian rule differ for the same tonometer?
Canada does not use the Spaulding vocabulary in the same way; it sets a minimum reprocessing level in a national standard. CSA Z314:23, the second edition published in 2023, revised the minimum reprocessing level for semi-critical medical devices and the handling of reusable medical devices, including risk assessment, and it widened its scope to professional offices and private practices. For a screening lane, that means the tonometer interface is not simply "wiped": it is reprocessed to the level the standard requires for a semi-critical device, with the device manufacturer's instructions in the chain.
The clinical side differs too. The Canadian Ophthalmological Society guideline recommends gonioscopy to classify an elevated pressure as open, closed or structurally abnormal, and notes that up to 61% of patients with primary open-angle glaucoma have a single screening pressure below 21 mm Hg. The American academy's preferred practice pattern for primary open-angle glaucoma describes an initial treatment target of a 20% to 30% reduction from baseline pressure and treats visual field testing and optical coherence tomography as complementary monitoring tools. Neither guideline supports a screening encounter that consists of one pressure reading and nothing else, which is what a consumable count built only around tonometer covers would imply.
| Item | Canada | United States |
|---|---|---|
| Device licensing or clearance | Health Canada device licence by class, with an establishment licence for the importer or distributor | FDA clearance through 510(k) where the product code requires it; exempt codes still register and list |
| Reprocessing rule for a tonometer interface | CSA Z314:23 minimum reprocessing level for semi-critical devices, with the manufacturer's instructions | CDC semicritical classification with high-level disinfection, following FDA-cleared instructions for the disinfectant |
| Clinical screening guidance | Canadian Ophthalmological Society glaucoma guideline, including gonioscopy to classify the angle | American Academy of Ophthalmology preferred practice pattern for primary open-angle glaucoma |
| Pressure as a screening result | Not sufficient alone; up to 61% of POAG patients have a single reading below 21 mm Hg | Same limitation; visual field and structural testing are the complementary monitoring tools |
| Per-encounter disinfection evidence | Reprocessing record per the standard and provincial guidance | Device instructions plus the disinfectant label contact time |
Which consumables are per patient and which are per day?
Per patient: gloves, swabs, any single-use occluder, any unit-dose drop or strip, and the disinfection event on each device that touched the patient. Per day or per session: the disinfection solution if it is a batch that has a use life, the calibration check consumables, and the printed record stock. Per device rather than per use: the reusable prism or tip, which is replaced on damage or at the interval the manufacturer states.
Mixing those three rhythms is how a lane ends up short at 10 a.m. A reorder level built only on patient volume will run out of the per-day item, and a level built only on the per-day item will carry months of single-use stock that ages on the shelf.
What should a purchase order for a screening lane state?
For chart cards, state the test distance and the chart type, because a Snellen card for a six-metre lane is not interchangeable with a near card at forty centimetres. For occluders, state whether they are single-use or wiped, since that decides the pack size. For swabs, state the tip material and whether the wrap is individual, because the tear film step is a single-swipe operation and a bulk pack changes the handling. For gloves, state the material and the size distribution rather than a single size. For disinfection material, state the contact time claim and compatibility with the tonometer prism or cover.
The most useful line on a screening-lane purchase order is the one that names the device the consumable will touch. A consumable specified against a device, rather than against a category, is the one that survives a change of tonometer or a change of disinfectant without a second purchase.
Encounter checklists, per-lane reorder sheets and a printed tray list are in the compliance log centre, which also carries a log generator for the reusable instruments in the same lane.
Comparing tonometer interfaces or building a per-lane standard kit? Send the device list and the patient volume, and the answer will name the rule it rests on. Ask a Compliance Specialist for the reprocessing side of the tonometer interface.
Buying for a group of lanes or a distribution account? The institutional account enquiry page covers case quantities and account setup, and the institutional collection lists the lines stocked for clinics. Reselling? become a distributor.
Related reading
- Cleaning a slit lamp and tonometer between patients: a step-by-step protocol
- Comparing three tonometers: Goldmann applanation, rebound and non-contact
- What auditors check about eye patch sets in Canadian clinics
Frequently Asked Questions
Is a tonometer a Class II device in the United States?
Yes. The manual and AC-powered tonometer codes sit under 21 CFR 886.1930 as Class II, and the classification database shows a submission type that requires a premarket notification. A dedicated tonometer sterilizer is separately classified at 21 CFR 886.1940 as Class I and exempt, which is why two devices on the same counter can sit in different regulatory categories.
Does a 70% alcohol wipe clean a tonometer tip adequately?
Not automatically. The CDC guideline records two reports in which disinfection of pneumotonometer tips between uses with a 70% isopropyl alcohol wipe contributed to outbreaks of epidemic keratoconjunctivitis caused by adenovirus type 8, and it points to FDA-cleared instructions for the disinfectant together with the guideline's own recommendations. A wipe with a stated contact time used as the label directs is a different process from a quick pass before the next patient.
How often should a screening lane change its disinfection solution?
At the interval the product label and the clinic's validated procedure state, and sooner if the solution is visibly soiled or the batch's use life has expired. The interval is a property of the disinfectant, not of patient volume, which is why the per-day rhythm and the per-patient rhythm have to be tracked separately.
Are eye patches consumed in a glaucoma screening encounter?
Not in a routine screening encounter, unless the protocol includes a procedure that requires occlusion or protection afterwards. They are consumed in acuity testing with monocular occlusion where a disposable occluder is used, and in post-procedure cover after laser or injection. That is why a lane's patch consumption tracks procedures rather than screening volume.
What is the difference between a screening pressure reading and a diagnosis?
The reading is one measurement. The Canadian guideline notes that up to 61% of patients with primary open-angle glaucoma have a single screening pressure below 21 mm Hg, and recommends gonioscopy to classify the angle; the American preferred practice pattern describes visual field testing and optical coherence tomography as complementary monitoring tools. A consumable count that assumes one pressure reading per patient is a count for a screening service, not for a diagnostic pathway.
Do single-use occluders and chart cards have to be recorded?
They do not carry a load record the way a reprocessed instrument does, but they do belong in the encounter record where the clinic's policy requires traceability. What matters commercially is the pack size and the unit of use, because a chart card that is wiped between patients consumes disinfection material rather than stock, and a single-use card consumes stock rather than material.
Which consumable runs out first in a busy screening list?
Gloves and disinfection material, because both scale with patient contacts rather than with procedures, and both are commonly ordered on a monthly rhythm set by procedure volume. A lane that adds screening sessions without revisiting those two lines will run short before it runs short of chart cards.
What should a clinic ask a supplier about tonometer prism compatibility?
Ask which tonometer models the prism or cover is validated for, what the device instructions say about the reprocessing method, and what the disinfectant's cleared label allows on that material. Compatibility is a three-way question between the tonometer, the interface and the disinfectant, and a supplier that answers only the first of the three has answered a third of it.
Sources
- CDC, Guideline for Disinfection and Sterilization: Disinfection of Healthcare Equipment — checked 20 November 2026.
- 21 CFR 886.1930, Tonometer — checked 20 November 2026.
- 21 CFR 886.1605, Perimeter — checked 20 November 2026.
- 21 CFR 886.1850, Slit-lamp biomicroscope — checked 20 November 2026.
- 21 CFR 886.1570, Ophthalmoscope — checked 20 November 2026.
- openFDA device classification database — checked 20 November 2026.
- CSA Z314:23, Canadian medical device reprocessing in all health care settings — checked 20 November 2026.
- Public Health Ontario, Reprocessing guidance, third edition — checked 20 November 2026.
- Canadian Ophthalmological Society glaucoma guideline, Can J Ophthalmol 2009;44 Suppl 1 — checked 20 November 2026.
- American Academy of Ophthalmology, Primary Open-Angle Glaucoma Preferred Practice Pattern — checked 20 November 2026.
- HealthLink BC, Glaucoma Screening — checked 20 November 2026.
- OSHA, Bloodborne Pathogens, 29 CFR 1910.1030 — checked 20 November 2026.
Regulatory and standards text is cited as published at the time of writing and is not reproduced in full. Rules and standards are amended, so confirm the current text before relying on a section. This article is for information and is not legal advice. CliniEco Medical distributes medical consumables under MDEL #35334.