Proving Bedpan Washer Cycle Competency at an Ontario Long-Term Care Home Without a Training Binder

Aurelia PerOxy disinfecting wipes, 0.5 percent hydrogen peroxide, 160 wipes per can, at the soiled utility room bench

Proving Bedpan Washer Cycle Competency at an Ontario Long-Term Care Home Without a Training Binder

The washer-disinfector sits in the soiled utility room, its cycle counter ticking over three shifts a day. A new infection prevention and control lead asks the administrator for the competency records and is handed nothing, because there is no training binder and there never was. That is not the gap it looks like.

What does Ontario require the home to prove?

The Fixing Long-Term Care Act, 2021 requires every licensee to have an infection prevention and control program, and O. Reg. 246/22 says what that program must contain. Section 102 sets out the team, the meeting rhythm and the education duty. What the regulation does not do is prescribe a per-staff certificate for each piece of equipment, so a reviewer looks for the program, not for a binder.

Who is accountable for the cycle at 3 a.m.?

CliniEco disposable non-woven bed sheets, 36 by 80 inch, stacked for a resident room in a long-term care home

A designated staff member. Section 102 (5) of O. Reg. 246/22 requires the licensee to designate an infection prevention and control lead with education and experience in the field, including cleaning and disinfection. Section 102 (6) goes further: that lead must hold a current certification in infection prevention and control from CBIC, the board that certifies the field, at the time of designation, or obtain it within three years. That is the named accountability a reviewer can test.

What three records stand in for a training binder?

What a reviewer asks What answers it Where it lives
Who oversees the washer cycle Named lead and designation date Program file
Was education delivered Session records and quarterly team minutes Team minutes
Is the practice correct in the room Audit results with dates and actions Audit file

Aurelia PerOxy disinfecting wipes, 0.5 percent hydrogen peroxide, 160 wipes per can, at the soiled utility room bench

Section 102 (7) puts education delivery and practice auditing on the lead, and section 102 (4) requires the interdisciplinary team to meet at least quarterly and to keep a written record of each annual program evaluation, including the date, the names of those who took part, a summary of the changes and the date they were implemented.

What belongs on a cycle log line?

Date, time the cycle started, the machine identifier, the cycle selected, the temperature or chemical indicator result if the machine reports one, and the initials of the person who ran it. Add the reason when a cycle is repeated. Two sets of initials for a shared shift is a warning sign, not a shortcut, because the page then cannot answer who was at the machine.

How often must the program be reviewed?

Annually for the program, quarterly for the team, and after any change of lead or machine. The annual review is the document that closes a competency question months later, because it names the people, the changes and the dates in one place.

Running a long-term care home? See our long-term care supplies for the room-level lines that sit beside the washer cycle.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. Fixing Long-Term Care Act, 2021, S.O. 2021, c. 39, Sched. 1, s. 23 (infection prevention and control program) (checked 23 November 2026)
  2. O. Reg. 246/22 (General), s. 11 and s. 102 (records; infection prevention and control program and lead) (checked 23 November 2026)

Printable companion: the equipment and maintenance log sheets print a washer cycle line with the fields a reviewer actually reads, so the page and the policy say the same thing.

Rebuilding the education file after a turnover? The clinic supply planner sets the review dates for the year so the quarterly check is not remembered in December.

Related Reading

Frequently Asked Questions

Is a certificate needed for every staff member who runs the washer?

No such certificate exists for the task. What the home produces is the program record: the lead who oversees education, the education actually delivered, and the audit that followed. A single-page competency check per staff member supports that record, but it is not the record itself.

What if the home cannot show education was delivered?

Then write the next one and date it. An undated claim is worth nothing; a dated session with a sign-in sheet and an audit two weeks later is worth everything a reviewer needs, and it can be produced the same afternoon.

Does the log have to be paper?

No. Section 11 of O. Reg. 246/22 asks for a readable and useable format that allows a complete copy to be readily produced. A spreadsheet with an audit trail meets that test; a locked tablet nobody can export from does not.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Already working with clinics? Become a regional representative.