Ontario Dental Clinic: How Long Must a Bite Block Reprocessing Record Be Kept, and Who Can Ask to Inspect It?

CliniEco 24-hour self-contained biological indicators, the daily result filed against each sterilizer

Ontario Dental Clinic: How Long Must a Bite Block Reprocessing Record Be Kept, and Who Can Ask to Inspect It?

A bite block goes into a patient's mouth, comes out, and into the autoclave with the rest of the load. Nobody thinks about it again until a patient reports a sore throat three weeks later and someone asks which cycle it was in. In Ontario that answer is a dated load line, and the line carries a clock. A dental x-ray bite block is a semi-critical item, which is why the load line has to name it rather than describing the load as assorted.

How long must an Ontario dental clinic keep a bite block reprocessing record?

Ten years after the last entry, and the wording is worth quoting. The Royal College of Dental Surgeons of Ontario requires clinical records and radiographs to be kept at least ten years after the last entry, and for a minor at least ten years after the patient turned eighteen. It then adds the sentence that decides this question: the same period applies to "other office records (such as equipment maintenance records, sterilization log and drug register)".

That sentence settles most of the argument. A bite block record is not filed with the chart, but it is not short-life either: the college's clock reaches the sterilization log by name.

Does a bite block go through the autoclave at all?

Dental x-ray bite blocks, a semi-critical item that has to be traced by load

Ontario's clinical office guidance answers directly: sterilization is always the preferred method for semi-critical equipment, high-level disinfection is for items that cannot tolerate heat, and a heat-stable bite block can take sterilization.

The same guidance sets what must exist per load: a logbook for each sterilizer load, physical indicators checked and signed for each cycle by the person sterilizing, a biological indicator once each day of use, and an internal chemical indicator inside each package.

What does the record have to capture?

Document What it proves Who signs it Clock
Load log line Items, cycle, result Person who ran the cycle 10 years
Daily biological indicator Unit worked that day Whoever reads it 10 years
Internal indicator The pack saw the conditions Person who assembled it 10 years
Recall record What was pulled and what was done Clinic lead 10 years

CliniEco 24-hour self-contained biological indicators, the daily result filed against each sterilizer

Day-to-day entries are simple: date, sterilizer, cycle, contents with sizes, indicator result, and the day's 24-hour self-contained biological indicator outcome. Sealed packs carry a dated sterilization indicator tape strip, a second date that has to agree with the log.

Who can ask to inspect it?

Four parties, and the first is the one clinics handle worst. A patient can request the record that concerns them, and a load line naming the bite block is part of the answer. The college can require records during a complaint. A public health inspector can ask during an inspection. An insurer or lawyer can ask with consent or a court order.

The practical preparation is one access rule: a single place, a single index, one person who can produce any load from any month in minutes. Ontario inspections test exactly that.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Running a dental practice? See our dental practice supplies and reprocessing lines, and the dental clinic range for bite blocks and load consumables by the case.

References

  1. Royal College of Dental Surgeons of Ontario, Information on dental recordkeeping: retention periods (checked 22 November 2026)
  2. Public Health Ontario, Infection Prevention and Control for Clinical Office Practice (November 2026), sterilizer monitoring and logbook (checked 22 November 2026)
  3. CSA Z314:23, Canadian medical device reprocessing in all health care settings (checked 22 November 2026)

Printable companion: the reprocessing SOP template names the load fields in the same order as the log, so a new staff member fills the sheet without inventing columns.

Working through the stations? The sterilization self-check runs the same sequence your IPAC inspection follows.

Not sure how this applies to your own setup? Ask a sterilization compliance specialist — you’ll get a written answer specific to your equipment and province, with the regulation or standard cited.

Related Reading

Frequently Asked Questions

Is a bite block a critical or semi-critical item?

Semi-critical. It contacts oral mucosa without entering tissue, so it needs high-level disinfection at minimum. Ontario guidance adds that sterilization is always the preferred method for this group, and a heat-tolerant bite block can take it.

Can the clinic keep one log for bite blocks and handpieces together?

Yes, as long as each item is named on the load line. A line reading "assorted" fails the recall test: a positive result cannot be narrowed to the instruments in the load.

What happens if the bite blocks were in a load with a positive biological indicator?

Quarantine the load, do not release it, and record the outcome, the items affected and the action taken. Ontario guidance expects a written recall procedure, and the record proves it ran.