10, 200 or 1000 uL Tips: How Do You Match a Tip to the Pipettor You Own?
Which tip goes with the pipettor on your bench?
Three numbers decide it: the maximum volume the pipettor is rated for, the barrel taper it was built around, and whether the work needs an aerosol barrier. The first is printed on the pipettor body. The second is in the tip's compatibility statement. The third comes from the assay, not from the catalogue.
For a single-channel 200 uL pipettor, the correct class is a 10 to 200 uL tip, which is what the MTC Bio 200 and 300 microlitre pipette tips, sterile racked, with gel-loading tips covers. For a 1 mL barrel, the class is 100 to 1000 uL. Picking one class down to save space on the shelf is the most common fitting error we see, and it shows up as a volume failure in gravimetric checks rather than as an obvious physical fault.
What do the three volume classes actually cover?
| Pipettor on the bench | Tip class | Typical tip length | Our line | Filter option | Rack format |
|---|---|---|---|---|---|
| Single-channel 10 uL | 0.1 to 10 uL | about 32 mm | quoted on request | yes | racked or bagged |
| Single-channel 200 uL | 10 to 200 uL | about 50 mm | MTC Bio 200 and 300 uL, sterile racked | yes, 300 uL filtered P4300-FT | rack of 96, or bulk bags |
| Single-channel 1000 uL | 100 to 1000 uL | about 70 mm | quoted on request | yes | rack of 96, or bulk bags |
| Electronic 5 mL | 1 to 5 mL, brand-locked | about 130 mm | MTC Bio 5 mL for Halo (H6505) and for ProPette LE (P4305) | no on these lines | bag of 100, or 6 racks of 24 |
| Electronic 10 mL | 1 to 10 mL, brand-locked | about 150 mm | MTC Bio 10 mL for ProPette LE (P4311) | no on these lines | bag of 100 |
The 10 mL line is MTC Bio 10 mL tips, bagged, for ProPette LE pipettors built in 2018 or later. The last two rows are where most laboratories get caught. Above 1 mL the tip is part of the pipettor's fit system rather than a universal fitting, so a 5 mL tip bought for a Halo electronic pipettor is not interchangeable with a 5 mL tip cut for a ProPette LE, even though both are described as 5 mL.

What does universal fit promise, and where does that promise stop?
A universal tip is moulded to a common barrel taper and will usually seat on a range of single-channel instruments from several makers. That is useful when a laboratory runs mixed brands and wants one SKU in the drawer. It stops at three places: electronic pipettors with a different ejector geometry, multi-channel pipettors where spacing has to match the tip rack, and positive-displacement or low-retention systems where the tip is part of the declared measuring set-up.
ISO 8655-2:2022 sets the metrological requirements for piston-operated pipettes themselves. What the standard does not do is certify a tip, so a laboratory that wants a defensible tip choice runs its own gravimetric check with the tip it actually stocks, rather than with the tip the pipettor was sold with.
When is a filtered tip mandatory?
A filter tip carries an aerosol barrier between the sample and the barrel. It is mandatory when the barrel has to stay free of nucleic acid, when you are pipetting volatile or corrosive solvents, when the sample itself must not cross-contaminate the next one, and in cell or tissue work where an aerosol can carry contamination back up the shaft. Those are workflow statements, and your own procedure should name them rather than leaving the choice to habit.

Outside those cases a non-filtered tip is the honest purchase. The MTC Bio filtered 300 uL pipette tips exist for the first case, not as an upgrade for every bench.
How do you check fit before you order a case?
Take one tip from a sample rack and seat it on the instrument with the volume set to its maximum. Check three things: the tip sits square with no rocking, the ejector throws it without a twist, and a water draw at maximum volume holds without a bubble forming at the seal. Then run a ten-delivery gravimetric check at 10 per cent, 50 per cent and 100 per cent of the range and compare with the tolerance on the pipette's own certificate.
If the check passes on one instrument, repeat it on the oldest one in the room. Age shows up in the seal first, and a tip that passes on a new pipettor can fail on a barrel whose O-ring has hardened.
Where to buy pipette tips in Canada
The racked, filtered and electronic-pipettor lines we stock sit together in the pipette tips collection, and the transfer and dispensing lines are in the pipetting and transfer collection. Laboratory buyers comparing formats can see the wider range on the laboratory consumables page.
A tip supplied sterile for laboratory use is a single-use consumable, and where it is supplied as a medical device the labelling requirements of the Medical Devices Regulations (SOR/98-282) apply to the seller. Sterility certificates and lot numbers still come from the manufacturer, and the certificate should name the lot on the case in front of you rather than a lot from last year.
Ordering for a hospital laboratory, a network of collection sites or a contract research group? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
References
- ISO 8655-2:2022, Piston-operated volumetric apparatus, part 2: pipettes (checked 23 November 2026)
- Medical Devices Regulations, SOR/98-282, Department of Justice Canada (checked 23 November 2026)
Printable companion: the lot and receipt templates record the tip lot against the bench that received it, which is the first question asked when a repeat result goes out of range.
Reordering is easier as arithmetic than as memory: the clinic supply planner converts a weekly tip count into racks, boxes and cases.
Related Reading
- Filtered, Low-Retention or Standard 200 uL Tips: How to Choose
- Do Filtered Pipette Tips Fit the Same Pipettes? Five Tip Systems Compared
- Wide-Bore vs Standard Pipette Tips: When 1000 uL Tips Need a Wide Opening
Frequently Asked Questions
Can I put a 200 uL tip on a 1000 uL pipettor?
No. The tip is rated for the pipettor it was moulded for, and a 200 uL tip on a 1 mL barrel sits proud of the seal, so liquid is drawn past the tip or the tip drops off mid-delivery. Order the 100 to 1000 uL class for that barrel.
What does universal fit actually promise?
That the tip fits many brands, not every brand. Universal tips are moulded to a common barrel taper, and they usually fit older single-channel pipettors from several makers, but they do not promise a seal on electronic or multi-channel models with a different ejector geometry.
When is a filtered tip mandatory rather than optional?
Whenever the barrel must stay clean: amplification set-up, work with volatile solvents, cell and tissue culture, and any sample that is infectious or hazardous. In routine chemistry and serology the filter mostly protects the pipettor rather than the sample.
How many tips does one rack cycle consume?
That is a bench question, not a catalogue one. Count the tips you discard in a normal shift on the busiest bench, multiply by the number of benches, and compare that figure with the rack size you order, rather than assuming one box per bench per month.
Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).