Three 200 µL tips sit on the same shelf and look almost identical: a standard tip, a filtered tip and a low-retention tip. The price difference between them is real, and the reason to pay it is specific to the sample and to what happens to that sample next. This comparison is written for the buyer who has to justify the choice on a purchase order and defend it in an audit.
If you are choosing between a filtered 200 µL tip, a low-retention 200 µL tip and a standard 200 µL tip, the difference that matters is function, not label language. What follows separates the three on that basis.


What does the filter actually block?
A filtered tip carries a porous barrier near the upper end of the tip, above the liquid column. Its job is to stop aerosol, droplets and vapour from reaching the pipette barrel and the shaft. That protects two things at once: the pipette, which is expensive to service and impossible to decontaminate inside, and the next sample, because a contaminated shaft is a cross-contamination route that no amount of tip changing fixes.
The barrier is not a sterile filter in the sense of a 0.2 µm membrane, and it does not ensure that the sample is free of nucleic acid. What it does is contain what happens inside the tip during aspiration, mixing and blow-out. For amplification work, that containment is the difference between a clean negative control and a mystery band.
When do you need a filtered tip?
Four situations justify the filter: polymerase chain reaction and any amplification setup, RNA work, handling of infectious or potentially infectious material, and any workflow where the pipette barrel is shared between samples that must not contaminate each other. In each case the risk being controlled is aerosol or carry-over reaching the barrel, and the filter is the only part of the system designed to stop it.
The situations that do not need one: buffer preparation, dilution series of standards, alcohol and detergent dispensing, and routine aqueous transfers where the pipette is dedicated to one reagent. A filtered tip in those workflows costs more per aliquot and adds nothing to the result.
| Attribute | Standard 200 µL tip | Filtered 200 µL tip | Low-retention 200 µL tip |
|---|---|---|---|
| Barrier against aerosol reaching the barrel | None | Hydrophobic barrier near the upper end | None |
| Sample left on the tip wall | Baseline | Baseline, plus barrier volume | Reduced by surface treatment |
| Typical use | Buffers, dilutions, routine transfers | Amplification, RNA, infectious material | Enzymes, dilute DNA, detergent-containing samples |
| Cost per aliquot | Baseline | Higher | Higher |
| Effect on pipetting technique | None | None, but do not over-aspirate into the barrier | Slightly slower uptake with viscous samples |
| What must be documented | Fit, volume, sterility if claimed | Fit, volume, sterility and the barrier specification | Fit, volume, and the retention claim wording |
What does low retention change?
A low-retention tip is treated so that the sample does not film the inside wall. The effect is small in absolute terms and large in relative terms: at 2 µL out of a 200 µL tip, the volume left behind can be a meaningful share of what was asked for. Low-retention tips matter most when the sample is scarce or expensive, when the concentration is near the detection limit, and when the liquid contains detergent or protein that wets plastic readily.
Low retention is not the same as low binding, although the terms are used loosely in catalogues. Ask what was measured: the volume recovered after a defined aspiration and dispense cycle, or the mass of protein adsorbed to the surface. A supplier that can name the test is giving you something to compare; a supplier that only says "low retention" is giving you a marketing word.
Which workflows justify the extra cost?
Filtered tips earn their cost in amplification and in any work with infectious material, because the alternative is a contaminated barrel and a repeat run. Low-retention tips earn their cost when the reagent is expensive (enzymes, master mixes, antibodies), when the sample volume is small relative to the tip, or when the assay is at the edge of its detection limit. Standard tips earn their cost everywhere else, which is most of the bench most of the time.
The common purchasing error is to standardise on the most expensive format for the whole lab. That raises the cost per case and trains users to ignore the difference. A better rule is one format per workflow, labelled and stored separately, so that the person at the bench picks the tip the protocol asks for rather than the one nearest the rack.
| Workflow | Tip to use | Why |
|---|---|---|
| PCR setup and master mix | Filtered | Aerosol containment protects the barrel and the negative control |
| RNA extraction and quantification | Filtered, nuclease claim checked | Barrel contamination and nuclease status both matter |
| Enzyme and master mix aliquoting | Low retention | Recovery of an expensive reagent at small volume |
| Dilute DNA standards | Low retention | Wall film is a large fraction of a small absolute amount |
| Buffer and saline preparation | Standard | No contamination route, no recovery problem |
| Handling infectious material | Filtered, sterile if required | Barrier plus the laboratory's own containment rules |
Do filtered tips fit the same pipettes?
The filter changes the internal geometry, not the outside, so fit is usually unchanged within the same tip family. The exception is over-aspiration: a filter tip has less usable column above the liquid, and a user who aspirates past the nominal mark can wet the barrier. Once wet, the barrier blocks air and the tip stops working, which shows up as a short delivery rather than as an error message.
When you change format, check fit on each pipette model and check the maximum aspiration volume that the tip tolerates before the barrier is reached. That number is not always printed on the bag, and it is the one that prevents the most common filtered-tip failure in routine use.
How do you compare sterile claims?
Sterility is a process claim, not an appearance. A tip that is individually wrapped is not automatically sterile, and a tip that is sterile is not automatically free of nucleases. Ask for the lot document: it should name the sterilization method, the lot, and the standard the process was validated against. For radiation-sterilized consumables the relevant family is ISO 11137, and for ethylene oxide it is ISO 11135.
For a laboratory working to ISO 15189:2022, the consumable is part of the quality record. Keeping the lot certificate with the receiving record turns a supplier claim into evidence that can be produced when someone asks how the sterile status of that box was established.
What should the purchase table list?
List what a user can verify: nominal volume, filter presence and barrier type, surface treatment and the exact retention claim, sterility status and method, rack format, and case count. Add a column for the workflow the format is intended for, because that is the column that stops a filtered tip being used for buffer.
The current listing is in the laboratory consumables collection. Buyers comparing the regulatory side can read the device class question for pipette tips and the P20 volume range guide before fixing a case count.
How does this fit Canadian and US documentation?
In Canada, pipette tips are general-purpose laboratory equipment; the distributor holds a medical device establishment licence, and CliniEco Medical distributes under MDEL #35334. In the United States, 21 CFR 862.2050 covers general-purpose laboratory equipment under general labelling controls. Neither route certifies the filter, the retention claim or the sterility of a particular lot. Those belong to the supplier's documentation and to the laboratory's own verification.
Where the tips touch biological material, the laboratory's biosafety manual and quality system govern. The Canadian Biosafety Standard and the WHO Laboratory Biosafety Manual describe containment expectations, and ISO 15189:2022 describes how equipment, consumables and records fit together.
Where does a lab take this next?
Three things a buyer can act on rather than read: a printable compliance log sheet that records receiving dates, lot numbers and open-on dates and exports from the browser; the clinic supply planner that turns bench counts into monthly quantities; and, where a sterile claim has to be documented for an auditor, Ask your compliance question which returns a written answer citing the regulation or standard it rests on.
Facility and multi-site buyers can Wholesale and multi-site ordering for case pricing and account setup. Reselling? become a distributor.
Related Reading
- Pipette tips in Canada vs the US: which device class applies
- P20 pipette: which volume range suits small-volume work
- Which pipette tips a Canadian research laboratory reorders monthly
Frequently Asked Questions
Are filtered tips sterile?
Not necessarily. Filtration and sterility are separate attributes. Check the lot document for the sterilization method and the standard it was validated against, and check the bag for a sterile claim.
Can I use low-retention tips for PCR?
You can, but low retention does not replace a filter. If the risk is aerosol reaching the barrel, use a filtered tip; if the risk is losing a small, expensive volume, use low retention.
Do low-retention tips change the delivered volume?
They change the volume left on the wall, which changes recovery. Verify with a gravimetric check at the volumes you use, and keep the tip lot in the record.
Is a filtered tip needed for every infectious sample?
Use one where the laboratory's risk assessment says the barrel could be contaminated. The filter contains aerosol; it does not replace containment equipment or technique.
What does DNase/RNase-free mean on a bag of tips?
It should mean the product was tested against a stated limit. Ask for the exact wording and the test behind it, because the phrase alone does not say what was measured.
Where can I compare the three formats?
Our laboratory range is listed in the laboratory consumables collection, and facility buyers can request case pricing through wholesale ordering.
Sources
- ISO 8655-2:2022, piston-operated volumetric apparatus — evs.ee
- ISO 8655-6:2022, reference measurement procedure — evs.ee
- ISO 11137-1:2025, radiation sterilization of health care products — evs.ee
- ISO 11135:2014, ethylene oxide sterilization — evs.ee
- ISO 15189:2022, medical laboratories — evs.ee
- Medical Devices Regulations, SOR/98-282 — laws-lois.justice.gc.ca
- 21 CFR 862.2050, general purpose laboratory equipment — law.cornell.edu
- Health Canada, medical devices — canada.ca
- Canadian Biosafety Standard, third edition — canada.ca
- WHO Laboratory Biosafety Manual — who.int
- CDC Laboratories — cdc.gov