Which sterile catheter and transfer supplies must a Canadian fertility clinic stock per retrieval cycle?
Which supplies are opened once per retrieval cycle?
A retrieval cycle opens two kinds of consumable: the ones that touch the follicular fluid and the oocytes, and the ones that hold and label what comes out of the procedure. The first group is small, sterile and specific. The second group is larger, less specific, and it is where the stock control actually lives.
The sterile 120 mL specimen containers with screw caps, 200 per case and the sterile 15 mL centrifuge tubes, 500 per case are the two lines that carry the sample end of a retrieval: the container for what is collected and labelled, the tube for what is washed and carried to the bench.
How does the transfer bench differ from the retrieval bench?
The retrieval bench is a tube-and-dish bench. Fluid arrives in a collection system, is transferred into tubes and dishes, and every transfer is a step where the consumable has to be sterile, labelled and traceable. The transfer bench is a catheter bench. One sterile device is loaded, one procedure is performed, and the consumable count is small while the documentation load is not.
That is why the two benches should be stocked separately. A cupboard organised around a single "procedure consumables" shelf mixes the high-volume tube stock with the low-volume catheter stock, and the low-volume line is the one that runs out without warning.

What has to be sterile, and what only needs to be clean?
| Item | Sterility | Single-use | Where it is opened | Record |
|---|---|---|---|---|
| Catheter for transfer | Sterile, in sealed pack | Yes | Transfer bench | Lot and expiry, checked on the day |
| Collection tubes, 15 mL and 50 mL | Sterile | Yes | Retrieval bench | Lot number on the cycle sheet |
| Specimen container for the sample | Sterile, leak-proof | Yes | Retrieval bench | Lot and patient identifier |
| Dishes for oocyte handling | Sterile | Yes | Retrieval bench | Lot number |
| Gloves at the procedure | Sterile at the field, examination grade elsewhere | Yes | Both benches | Lot number for the procedure gloves |
| Bench covers and outer packaging | Not required to be sterile | Yes | Both benches | None, but must be non-shedding |
The line between "sterile" and "clean" is drawn by contact, not by price. Anything that enters the body, touches gametes or embryos, or holds material that will, is sterile. Anything that only touches the outside of a sterile pack is clean, provided it does not shed fibres onto the field.
How do you build the per-cycle pick list?
Write the list from the procedure backwards. Start with the last thing opened - the transfer catheter on the transfer day - and work back through the dishes, tubes, containers and gloves to the first item opened during retrieval. Each line gets a quantity per cycle and a pack size, and the pack size decides how many cycles one case covers.

Two checks make the list usable. The first is a name on each line, so a locum can pull the stock. The second is a lot field, so the cycle sheet and the case label can be matched without hunting through a diary. A pick list without lot fields is a shopping list, not a record.
What changes if the clinic handles donor gametes?
The consumables do not change; the labelling and record obligations do. Donated sperm and ova bring the Safety of Sperm and Ova Regulations (SOR/2019-192) into the cycle, which adds donor suitability assessment and labelling and record requirements to the clinic's own paperwork.
At the bench that shows up as a second label and a longer chain of custody on the sample container, and it is worth rehearsing before the first donor cycle rather than during it. A container labelled for the wrong patient is a serious event, and the consumable is what carries the identity.
Where to buy the consumables in Canada
The parafilm and serological pipettes and the rest of the transfer range sit in the pipetting and transfer collection, and the specimen handling lines sit in the specimen collection and waste collection. Clinics building a standard cupboard across several sites can compare formats on the laboratory consumables page.
A catheter supplied for clinical use is a medical device in Canada, and the labelling requirements of the Medical Devices Regulations (SOR/98-282) apply to the device and to the seller's obligations. The regulation does not tell a clinic which catheter to stock; the clinic's own procedure and the transfer technique its clinicians use decide that.
Ordering for a fertility clinic, a satellite site or a hospital-based programme? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
References
- Medical Devices Regulations, SOR/98-282, Department of Justice Canada (checked 23 November 2026)
- Safety of Sperm and Ova Regulations, SOR/2019-192, Department of Justice Canada (checked 23 November 2026)
Printable companion: the lot and receipt templates give each retrieval a single sheet listing the consumables opened, with lot numbers and the date.
Sizing the cupboard for a cycle list rather than a patient count? The clinic supply planner converts retrieval cycles per month into tubes, containers and cases.
Related Reading
- Fertility Care Supplies: Disposable Consumables for IVF Clinics
- How Should a Fertility Clinic Segregate Biomedical Waste in Canada?
- Which Pipette Tips Does a Canadian Research Laboratory Reorder Monthly?
Frequently Asked Questions
Is an embryo transfer catheter reusable?
No. Transfer catheters are supplied sterile and single-use, and a catheter that has entered the cervix is not re-sterilised for a second attempt. If a transfer has to be repeated, a new catheter is opened.
What is the difference between the retrieval bench and the transfer bench?
The retrieval bench handles follicular fluid and oocytes and works with tubes, dishes and aspiration lines. The transfer bench handles a loaded catheter and the documentation around it, and it needs far fewer consumables but the same discipline about sterility and labelling.
Which consumables must be sterile rather than just clean?
Anything that enters the body or touches gametes or embryos: catheters, collection tubes, dishes, specimen containers and gloves used at the procedure. Bench covers and outer packaging do not need to be sterile, but they must not shed.
How far ahead of a retrieval cycle should the consumables be checked?
At least a week, and again on the day. The check is not only that the item is in the cupboard but that its lot number, expiry and packaging are intact, because a compromised pack found five minutes before a retrieval has no replacement path.
Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).