Quick facts
- A custom tray is made from a patient's model or scan, so the gel stays where it is placed and the gingival margin is sealed. A prefilled tray is a universal shape that relies on the patient's bite to hold it in position.
- The tray is only half the product. In Canada the whitening gel is regulated on its own terms, and Health Canada's 2024 guidance sets out the evidence required for cosmetic tooth whitening products containing peroxide and peroxide-generating compounds.
- That guidance requires salivary peroxide data where a product contains more than 3% w/w hydrogen peroxide equivalents, and it describes the clinical study and the trained staff, such as a dentist, who must screen participants.
- 21 CFR 872.6475 covers a heat source for bleaching teeth, and 21 CFR 872.6880 covers a preformed impression tray; a custom tray made for one patient is a different object from a preformed tray on a shelf.
- RCDSO standards and the practice's own record system decide what is kept: the prescription, the shade, the tray, the gel concentration, the instructions and the follow-up.
- Regulatory text and guidance were read on 2026-10-19. This article compares procurement routes; it does not classify any particular gel or tray.
A whitening tray looks like a simple piece of plastic, and the choice between a custom tray and a prefilled tray is usually made on price per patient. The price is the least interesting part of the decision: the two products differ in fit, in how much gel reaches the gingiva, in what the practice can record, and in the regulatory route the gel travels. This article compares the two workflows for a Canadian practice, sets out the evidence Health Canada asks for when a product contains peroxide, and lists the records that make a whitening case auditable; the chairside bibs used during the impression and the fitting are in the three-layer paper and PE bib range.
What is the difference between a custom tray and a prefilled tray?
A custom tray is fabricated from an impression or an intraoral scan. It follows the arch, covers the teeth to the gingival margin and leaves a reservoir for the gel. The fit is the point: a tray that seals at the margin keeps the gel on the tooth and away from the gingiva, and a tray that does not seal does the opposite.
A prefilled tray is manufactured in a small number of sizes with the gel already in the trough. The patient seats it, bites, and removes it after the specified time. The advantage is convenience and a controlled dose per tray; the disadvantage is that the fit is approximate, so the gel can pool at the gingival margin or fail to reach a rotated tooth.
The clinical difference is not that one works and the other does not. It is that the custom tray moves the fit decision to the practice, where it can be checked, and the prefilled tray moves it to the patient, where it cannot.
| Item | Custom tray | Prefilled tray |
|---|---|---|
| Fit | Made to the patient's arch | Universal size, approximate |
| Gel placement | Reservoir and sealed margin | Fixed volume in the trough |
| Chair time | Impression or scan, then fitting | Dispense and instruct |
| Lab involvement | Yes, with a prescription | None |
| Records | Model or scan, prescription, shade, gel | Product lot, shade, instructions |
| Suits | Higher concentration, sensitivity risk, complex anatomy | Low concentration, convenience, short courses |
How is the gel regulated in Canada?
The tray is a device or a custom-made item; the gel is a separate product with its own route. Health Canada's 2024 guidance addresses cosmetic tooth whitening products containing peroxide and peroxide-generating compounds and describes the safety evidence a notifier must hold, including the clinical study that supports the salivary peroxide exposure.
The threshold that matters in practice is 3% w/w hydrogen peroxide equivalents. Above that level the guidance requires salivary peroxide data, and the study it describes must be conducted with trained staff, such as a dentist, screening participants. A practice that buys a high-concentration gel should therefore know which product it is using and what evidence the supplier holds.
The cosmetic route also carries the ordinary cosmetic obligations: the ingredient list, the dealer information and the notification. A product that makes therapeutic claims moves to the drug route, and the practice should not assume that a product sold as a whitening gel is a cosmetic simply because it is sold in a dental office.
| Question | Canada | United States |
|---|---|---|
| Product category | Cosmetic or drug, depending on claims and concentration | Cosmetic or drug, depending on claims |
| Peroxide threshold in guidance | More than 3% w/w hydrogen peroxide equivalents triggers salivary peroxide data | Monograph and labelling route applies to drug products |
| Labelling basis | Cosmetic Regulations or drug labelling | 21 CFR 701.3 or Drug Facts under 21 CFR 201.66 |
| Tray | Device or custom-made item; IFU applies | 21 CFR 872.6880 for a preformed tray |
What does a custom tray workflow require?
The workflow starts with an impression or a scan, a bite registration where needed, and a prescription that states the material, the shade and the reservoir design. The laboratory returns a tray with a record of the model and the material, and the practice checks the fit before the patient leaves.
The fitting appointment is the control point. The tray should seat fully, the margin should roll over the gingiva rather than dig into it, and the patient should be able to insert and remove it without force. A tray that is short at the premolars or gaps at the incisal edge will produce an uneven result and a sensitivity complaint.
The prescription and the fitting note belong in the patient record. If the case is later reviewed, the practice should be able to show which tray was made, from which model, with which material, and what the patient was told about wear time and sensitivity.
What does a prefilled tray workflow require?
The prefilled workflow is a dispensing and instruction workflow. The practice confirms the indication, checks the product's concentration and label, records the lot, and gives the patient written instructions that match the manufacturer's directions. The fit check is limited to asking the patient to seat the tray and confirm that it is comfortable.
The record is correspondingly thinner, which is the point and the risk. The practice can show what was dispensed and when, but it cannot show a model or a prescription because there was none. If the patient returns with sensitivity or an uneven result, the record supports a review of the product, not of the fit.
A prefilled tray is a reasonable route for a low-concentration, short course in a patient with a straightforward arch. It is a poor route for a patient with crowns, rotated teeth or a history of sensitivity, because the tray cannot be adapted to any of those conditions.
How should a practice decide what to stock?
Start with the case mix. A practice that sees a high proportion of aesthetic cases and wants control over gel concentration and fit should keep a custom tray workflow and a small stock of prefilled trays for convenience courses. A practice that mainly dispenses take-home kits can run on prefilled trays with a clear referral route for complex cases.
Then check the supply chain. A custom tray needs a laboratory relationship, a turnaround time and a prescription template. A prefilled tray needs a supplier with a stable lot and a label the practice can read. Both need a record that ties the product to the patient.
Finally, check the claims. The practice's own website and consent form should describe the treatment in the same terms the product is authorised to use. A page that promises to repair enamel is making a claim the product may not support.
| Practice profile | Custom tray | Prefilled tray | Reason |
|---|---|---|---|
| Aesthetic-focused, high case volume | Core | Backup | Fit and gel control |
| General practice, occasional whitening | Refer out | Core | Convenience, low stock |
| Patients with crowns or rotated teeth | Core | Not suitable | Fit cannot be adapted |
| Sensitivity-prone patients | Core, lower concentration | Only if concentration is low | Gel control and margin seal |
| Multiple operators | Core with shared prescription template | Core with lot log | Consistency and records |
What records make a whitening case auditable?
The record should hold the indication, the shade at baseline, the tray type and material, the gel product and concentration, the lot, the instructions given, the wear time, the follow-up dates and any adverse event. For a custom tray it should also hold the model or scan identifier and the laboratory prescription.
The record is not only a defence. It is the data set that lets the practice improve: which concentration produced which sensitivity rate, which tray design produced which shade change, which patients needed a second course. A practice that records the variables can answer those questions; one that records only the invoice cannot.
Retention follows the practice's record policy and the college requirements that apply to it. The important point is that the whitening record is part of the clinical record, not a separate retail file that can be discarded when the promotion ends.
A whitening workflow reorders the chairside barrier items at the same time. Order through the wholesale programme for case pricing and an account, or become a distributor for resale. The three-layer paper and PE dental bibs sits in the same catalogue. Consumables for this line are listed under the department page.
Sources
- Health Canada, evidence of safety requirements for tooth whitening products containing peroxide
- Health Canada, what is a cosmetic?
- Cosmetic Regulations, C.R.C., c. 869
- Food and Drugs Act, R.S.C., 1985, c. F-27
- Competition Act, R.S.C., 1985, c. C-34
- 21 CFR 872.6475, heat source for bleaching teeth
- 21 CFR 872.6880, preformed impression tray
- 21 CFR 701.3, designation of ingredients
- 21 CFR 201.66, over-the-counter drug product labels
- Medical Devices Regulations, SOR/98-282
- Health Canada, medical devices
- Health Canada, establishment licensing
- Royal College of Dental Surgeons of Ontario, infection prevention and control
- Royal College of Dental Surgeons of Ontario, standards and guidelines
- Canadian Dental Association
- ISO 13485:2016, medical devices quality management
- ISO 14971:2019, application of risk management to medical devices
- ISO 17664-1:2021, processing of health care products
- CSA Group, standards catalogue
Printable whitening case record. The shade, the tray, the gel concentration and the lot belong on one sheet, signed at the fitting. Print a whitening case record - one page per patient, with a baseline shade box, a tray and gel block and a follow-up row; it prints with no account and no sign-up.
Log generator. Build a lot and follow-up register so that a sensitivity report can be traced to a gel lot. Build a whitening lot register - the page creates dated rows for the lot, the patient, the concentration and the follow-up outcome.
Ask a compliance specialist. Whether a gel is a cosmetic or a drug in Canada, and what evidence the supplier must hold above 3% peroxide, are questions that turn on the label and the claim. Ask a compliance specialist - written answer specific to your product and province, with the regulation or standard it is based on cited.
Related reading
- Teeth whitening products in Canada and the US: which standards apply
- Dental dam sizes compared: which sheet size fits which procedure
- Dental dam storage and shelf life: a Canadian clinic guide
CliniEco Medical supplies eye care, laboratory and dental consumables of the kind described in this article. MDEL #35334. This article is written for dental practice owners and buyers and is not legal advice; the classification of a whitening product and the records a practice keeps belong to the product and to the college requirements that apply.
Frequently Asked Questions
Are custom whitening trays better than prefilled trays?
They are different products. A custom tray fits the patient's arch and seals at the gingival margin, which gives more control over where the gel goes. A prefilled tray is more convenient and carries a fixed dose, but the fit is approximate.
What peroxide concentration triggers extra evidence in Canada?
Health Canada's 2024 guidance requires salivary peroxide data where a tooth whitening product contains more than 3% w/w hydrogen peroxide equivalents, and describes the clinical study that supports the exposure assessment.
Is a whitening gel a cosmetic or a drug?
It depends on the claims and the concentration. A product sold to improve appearance is normally a cosmetic; one that claims to treat a condition or modify a body function is a drug. The label and the advertising decide.
What should a custom tray prescription contain?
The material, the shade, the reservoir design, the model or scan identifier and the patient identifier. The practice should keep the prescription and the fitting note in the clinical record.
Can a prefilled tray be used on a patient with crowns?
It can, but the fit is not adapted to the crown margins and the gel may pool at the gingival margin. A custom tray is the more controllable route for a patient with crowns, rotated teeth or a history of sensitivity.
What records should a whitening case keep?
The indication, baseline shade, tray type and material, gel product and concentration, lot, instructions, wear time, follow-up dates and any adverse event. The record belongs with the clinical record, not in a separate retail file.