{"product_id":"sterile-blood-lancets-33g-100-box","title":"Sterile Blood Lancets 33G — 100\/Box","description":"\u003cp\u003eSterile single-use lancets with a 33 gauge point, supplied 100 per box, for capillary blood sampling in glucose monitoring and point-of-care testing. Each lancet is used once and disposed of in a sharps container.\u003c\/p\u003e\n\u003cp\u003eGauge and depth both affect sampling: a thinner lancet is usually less painful but needs good capillary flow, so clinics with cold-hand or low-perfusion patients often keep a second size on hand.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiabetes education and monitoring clinics\u003c\/li\u003e\n\u003cli\u003eFamily practices running point-of-care glucose tests\u003c\/li\u003e\n\u003cli\u003eLong-term care homes and retirement residences\u003c\/li\u003e\n\u003cli\u003ePharmacies offering screening services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSterile, single use, 100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapillary blood sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat lancet gauge should a clinic stock?\u003c\/h3\u003e\n\u003cp\u003eMost clinics stock one mid-range gauge for routine use plus a smaller gauge for patients with reduced perfusion or when comfort is the priority. 33G sits at the fine end.\u003c\/p\u003e\n\u003ch3\u003eAre lancets reusable?\u003c\/h3\u003e\n\u003cp\u003eNo. Lancets are single use for both infection control and skin-trauma reasons, and each one goes straight into a sharps container.\u003c\/p\u003e\n\u003ch3\u003eDo lancets need to be disposed of as sharps?\u003c\/h3\u003e\n\u003cp\u003eYes. Lancets are a sharps stream even when the point is retracted into a housing, because the housing can be breached in waste handling.\u003c\/p\u003e\n\u003ch3\u003eHow do I ask about volume supply?\u003c\/h3\u003e\n\u003cp\u003eUse our B2B enquiry form and we will confirm documentation status and availability.\u003c\/p\u003e\n\u003ch2\u003eWhat does 33G mean on a blood lancet?\u003c\/h2\u003e\n\u003cp\u003eGauge describes the outside diameter of the point, not how deep it cuts. In the ISO 9626:2016 needle tubing series, 33G is the 0.20 mm designated size: one step finer than 32G at 0.23 mm, and the second-finest size in a series that stops at 34G (0.18 mm). A finer point parts less tissue, which is why fine gauges are associated with less discomfort at the puncture. Gauge alone does not set the sample, though, because the incision depth comes from the lancing device that holds and drives the lancet. A 33G lancet in a device set shallow can produce a smaller drop than a 30G lancet at a deeper setting, so clinics pair a fine gauge with an adjustable device instead of assuming that the finest lancet is the kindest one for every patient.\u003c\/p\u003e\n\u003ch2\u003eWhy is a multi-patient lancing device not acceptable, even with a new lancet?\u003c\/h2\u003e\n\u003cp\u003eHealth Canada addressed this directly in its notice of 26 September 2014 on licensing requirements for lancing devices and blood glucose monitoring systems (file 14-111696-560). The notice states that multi-patient use of lancing devices has been documented to pose a risk of disease transmission even if a new lancet is used for every patient. It also states that Health Canada will license lancing devices only if they are labelled as auto-disabling or for single-patient use, that point-of-care meters intended for multiple patients are licensed only with auto-disabling single-use lancing devices, and that the meter labelling must instruct health care personnel to change gloves between patients. The same notice records a 2012 Canadian incident in which a device designed for one person was used to obtain blood samples from 72 staff and students. A single-use lancet is therefore half of the control; the holder is the other half.\u003c\/p\u003e\n\u003ch2\u003eWhich documents belong in a lancet specification file?\u003c\/h2\u003e\n\u003cp\u003eSterility comes first: sterilisation validated to ISO 11135:2014 for ethylene oxide or to the ISO 11137 series for radiation, to a sterility assurance level of 10\u003csup\u003e−6\u003c\/sup\u003e, with the sterile barrier system qualified to ISO 11607-1:2019 and a stated shelf life. Biological safety is assessed under ISO 10993-1:2018. In Canada the device licence belongs to the manufacturer, while the importer or distributor holds a Medical Device Establishment Licence; CliniEco Medical distributes under MDEL #35334. For the glucose side of the workflow, Health Canada recognised ISO 15197:2013 for blood glucose monitoring systems for self-testing in the same 2014 notice, with a one-year transition for new devices. Marks belong to jurisdictions too: a CE mark is the manufacturer's declaration of conformity for the European market and is not evidence of Canadian licensing, so a Canadian file still needs the licence reference and the establishment licence number beside it. A specification file that holds those documents answers most of a procurement review before it starts.\u003c\/p\u003e\n\u003ch2\u003eHow should used lancets be handled in a Canadian clinic?\u003c\/h2\u003e\n\u003cp\u003eA lancet is single use and goes into a sharps container at the point of use, point first, without recapping by hand. Waste rules are provincial rather than federal. In Ontario, guideline C-4, The Management of Biomedical Waste in Ontario, lists human blood waste in Table A with a yellow label and the universal biohazard symbol, and sharps go into a puncture-resistant, closeable container. A clinic in another province has to name its own rule instead of copying the Ontario one, and a policy written for sites in several provinces should cite the jurisdiction beside each requirement. Add the audit trail: container fill level, replacement date, and the person who closed and labelled it.\u003c\/p\u003e\n\u003ch2\u003eWhat should be checked when a box of lancets arrives?\u003c\/h2\u003e\n\u003cp\u003eCheck the label against the requisition for gauge, box count and single-use wording; check that the sterile barrier is intact and the expiry date has not passed; confirm the carton has been stored dry and away from heat; and record the lot number on the receiving record so a supplier notice can be traced to a drawer. Keep one opened sample with the training file if the clinic trains new staff on lancing technique. Our \u003ca href=\"\/products\/clinieco-blood-glucose-monitor-kit-complete-diabetes-testing-kit-with-50-test-strips\"\u003eblood glucose monitor kit\u003c\/a\u003e, \u003ca href=\"\/products\/insulin-syringes-1cc-31g-100-box\"\u003e1 cc insulin syringes\u003c\/a\u003e and \u003ca href=\"\/products\/sharps-container-1-quart-20-case\"\u003e1-quart sharps container\u003c\/a\u003e are documented the same way, and volume requirements run through the \u003ca href=\"\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e33G blood lancet: what each specification changes\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat it changes at the bedside\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003e33G, 0.20 mm nominal outside diameter in the ISO 9626:2016 series\u003c\/td\u003e\n\u003ctd\u003eTissue trauma and discomfort at the puncture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCutting depth\u003c\/td\u003e\n\u003ctd\u003eSet by the lancing device, not by the lancet\u003c\/td\u003e\n\u003ctd\u003eDrop size, and whether a second puncture is needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eSterile, single use, 100 per box\u003c\/td\u003e\n\u003ctd\u003eOne lancet per patient, then straight into sharps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice labelling\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eAuto-disabling or single-patient use, per Health Canada's 2014 notice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 or the ISO 11137 series, sterility assurance level 10\u003csup\u003e−6\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11607-1:2019 qualification and stated shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBiocompatibility\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 10993-1:2018 evaluation for skin contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number recorded on the supplier file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical supplies blood sampling consumables to Canadian clinics under MDEL #35334. This section is a specification reference; lancet and lancing device selection remains a clinical decision.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/diabetes-management-supplies-canadian-patients-glucometers-test-strips\"\u003eDiabetes management supplies: glucometers, strips and lancets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/sharps-containers-in-canada-types-regulations-and-sizes-explained\"\u003eSharps containers in Canada: types and sizes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/blood-glucose-monitor-procurement-for-canadian-clinics-testing-kits-and-compliance\"\u003eBlood glucose monitor procurement for Canadian clinics\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"4-Pack","offer_id":49081999392990,"sku":"CLI-LANCET-100-4PK","price":43.0,"currency_code":"USD","in_stock":true},{"title":"Single","offer_id":49039190720734,"sku":"CLI-LANCET-100","price":11.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/sterile-blood-lancets-33g-100-box-1.jpg?v=1789404344","url":"https:\/\/clinieco.com\/products\/sterile-blood-lancets-33g-100-box","provider":"CliniEco Medical","version":"1.0","type":"link"}