{"product_id":"soco-prismatic-dental-loupes-4-0x-450mm","title":"SOCO Prismatic Ergonomic Dental Loupes 4.0x — Angled 45°, 450 mm","description":"\u003cstyle\u003e\n.soco-prod{max-width:780px;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,sans-serif;color:#111827;line-height:1.65;font-size:16px}\n.soco-prod h2{font-size:20px;color:#123a2f;border-bottom:2px solid #E5E7EB;padding-bottom:8px;margin:32px 0 12px}\n.soco-prod h3{font-size:17px;color:#206270;margin:24px 0 8px}\n.soco-prod p{margin:0 0 12px}\n.soco-prod ul{margin:0 0 14px;padding-left:20px}\n.soco-prod li{margin-bottom:8px}\n.soco-prod img{max-width:100%;height:auto;border-radius:10px;display:block;margin:14px 0}\n.soco-prod table{width:100%;border-collapse:collapse;margin:14px 0;font-size:14.5px}\n.soco-prod th{background:#123a2f;color:#ffffff;text-align:left;padding:10px 12px;border:1px solid #123a2f;font-weight:600}\n.soco-prod td{border:1px solid #E5E7EB;padding:10px 12px;vertical-align:top}\n.soco-prod tbody td:first-child{background:#F9FAFB;font-weight:600}\n.soco-note{background:#FFF7ED;border:1px solid #FDBA74;border-radius:8px;padding:14px 16px;font-size:14.5px;color:#7C2D12;margin:16px 0}\n.soco-meta{font-size:14px;color:#4B5563}\n@media (max-width:600px){.soco-prod{font-size:15.5px}.soco-prod h2{font-size:18px}.soco-prod table{font-size:13.5px}.soco-prod th,.soco-prod td{padding:8px 9px}}\n\u003c\/style\u003e\n\u003cdiv class=\"soco-prod\"\u003e\n\n\u003cp\u003eSOCO 4.0x prismatic dental loupes hold a 70 mm field of view across an 80 mm depth of field on a 45° angled optical path, in a 65 g fixed frame built to your measured working distance — the step where magnification stops being a comfort measure and becomes a diagnostic instrument. Four power is the point in the ladder where the question changes from \"can I see the tooth\" to \"can I see what is wrong with it\", and the tightness of the field is the price of that change.\u003c\/p\u003e\n\n\u003cp class=\"soco-note\"\u003e\u003ca href=\"\/en-us\/products\/soco-prismatic-dental-loupes-4-0x-450mm\"\u003eShopping from the US? USD pricing and US delivery\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SOCO-SCE300-40-450.jpg?v=1795235339\" alt=\"SOCO SCE300-40-450 prismatic dental loupes, 4.0x, 45-degree angled optical path on a fixed frame with adjustable pupillary distance\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch2\u003eWhat are SOCO 4.0x prismatic dental loupes?\u003c\/h2\u003e\n\u003cp\u003eTwo prisms fold a long focal path into a short barrel, and the barrel is set at 45° to your line of sight so the optical axis points down into the mouth instead of straight ahead. The published values are 4.0× magnification, a 70 mm field at 450 mm, 80 mm of depth of field, 65 g net weight, pupillary distance adjustable across 50–80 mm, and a fixed non-flip mount.\u003c\/p\u003e\n\u003cp\u003eThat combination — prismatic, angled, fixed — is a design decision rather than a specification upgrade. A Galilean pair at 3.5× gives you more field and more depth, and it is lighter in the hand; a prismatic pair at 4.0× gives you a narrower, flatter, more evenly resolved image and a posture that does not require you to lean into the work. The two are not versions of one another.\u003c\/p\u003e\n\n\u003ch2\u003eWhy step up to prismatic 4.0x instead of a 3.5x Galilean pair?\u003c\/h2\u003e\n\u003cp\u003eBecause the limit you hit at 3.5× is usually optical rather than visual. Resolution at the edge of a Galilean field falls away before the centre does, and the field is wide enough that the difference is easy to live with — until the work moves to a margin, a crack line, or a canal orifice. Prismatic optics keep resolution closer to uniform across a smaller field, which is the trade you are accepting: less area, more information per millimetre.\u003c\/p\u003e\n\u003cp\u003eThe other half of the answer is posture. An angled path lets the barrels point down while your head stays closer to upright, so the neck angle that a straight-through lens demands is not required. In a crossover study of 29 dental hygiene students and faculty, vertically adjustable front-lens-mounted loupes — the configuration that permits a steeper declination — produced significantly lower head tilt than through-the-lens loupes in both arches (p = 0.000; d = 1.21 mandibular, d = 0.70 maxillary), and the authors note that a declination angle of 40°–50° is what maintains minimal forward head posture (\u003ca href=\"https:\/\/jdh.adha.org\/content\/jdenthyg\/95\/3\/59.full\"\u003eWilson et al., J Dent Hyg 2021;95(3):59–64\u003c\/a\u003e, checked 2026-11-21). The 45° path on this pair sits inside that band by design, not by accident.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SOCO-SCML05.jpg?v=1795237188\" alt=\"SOCO SCML05 coaxial LED headlight with bayonet clip, the optional light that fits the SOCO 4.0x prismatic frame\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch2\u003eWhat do the published specifications say?\u003c\/h2\u003e\n\u003cp\u003eEverything below is taken from this listing. Where a second surface of the same listing states something different, the specification card is the value quoted here.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue on this listing\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e4.0×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view\u003c\/td\u003e\n\u003ctd\u003e70 mm at 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking distance\u003c\/td\u003e\n\u003ctd\u003e450 mm standard; 400–580 mm built to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e65 g net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePupillary distance\u003c\/td\u003e\n\u003ctd\u003e50–80 mm, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeadlight\u003c\/td\u003e\n\u003ctd\u003eOptional SCML05 coaxial LED, bayonet clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe remaining published values are: optical system prismatic (Keplerian), optical path angled 45° downward, depth of field 80 mm, mount fixed and non-flip. Nothing on this page is an estimate.\u003c\/p\u003e\n\n\u003ch2\u003eHow much field is 70 mm in practice?\u003c\/h2\u003e\n\u003cp\u003eAbout one tooth, plus the interproximal space on either side, at the 450 mm distance. That is enough to prepare a class II or refine a veneer margin without moving your head, and not enough to survey a quadrant. A full-mouth examination at 4.0× becomes a sequence of deliberate moves rather than one sweep, and a second molar means repositioning the patient rather than widening the view.\u003c\/p\u003e\n\u003cp\u003eWhether that is a limitation depends on the appointment mix rather than on the operator's skill. Hygienists doing quadrant scaling lose time; clinicians doing endodontic access, margin finishing, or crack detection gain resolution exactly where they were previously guessing. The honest summary is that 70 mm is a working field, not an examining field.\u003c\/p\u003e\n\n\u003ch2\u003eDoes 4.0x actually improve the work, or only the view?\u003c\/h2\u003e\n\u003cp\u003eThe accuracy evidence at this level is thinner than the ergonomic evidence, and it is worth stating that plainly. A 2026 randomised clinical trial compared treatment accuracy using 2.5× magnification against the naked eye (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42245847\/\"\u003eCureus 2026;18(5):e108204, PMID 42245847\u003c\/a\u003e, checked 2026-11-21); at lower powers than this pair, so it does not settle the 4.0× question. What the magnification literature does support is that measured near visual acuity and self-assessed acuity diverge: in a study of dental hygienists, self-assessment correlated only weakly with measured performance (r = 0.27) and individual variation in resolution reached up to 300% (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29603638\/\"\u003eInt J Dent Hyg 2018;16(3):357–361, PMID 29603638\u003c\/a\u003e, checked 2026-11-21).\u003c\/p\u003e\n\u003cp\u003eThat is the strongest practical argument for choosing this pair on measurement rather than on preference. If your measured acuity is already marginal at 450 mm, 4.0× buys more than it would for a colleague whose unaided acuity is excellent; the number is the specification, not the feeling.\u003c\/p\u003e\n\n\u003ch2\u003eWhat working distance and pupil distance should you measure?\u003c\/h2\u003e\n\u003cp\u003eThe working distance is the distance from the outer corner of your eye to the point where the instrument meets the tooth, taken in the posture you actually work in, with the patient positioned as you normally position them. The listing builds 450 mm as standard and anything from 400 mm to 580 mm to order, so the measurement is not a preference — it is what the pair is made to.\u003c\/p\u003e\n\u003cp\u003ePupil distance is the second measurement, and it is adjustable across 50–80 mm. Both matter more than clinicians expect: in a survey of 308 loupe owners, fitting and magnification review after purchase were rarely carried out, which means a pair that was slightly wrong at delivery stayed slightly wrong for years (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eJ Dent 2026;169:106661, PMID 41903621\u003c\/a\u003e, checked 2026-11-21). Practices buying for several operators can send one measurement list through the \u003ca href=\"\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e rather than measuring one clinician at a time.\u003c\/p\u003e\n\n\u003ch2\u003eIs 4.0x enough for molar endodontics?\u003c\/h2\u003e\n\u003cp\u003eFor access, yes; for the canal itself, usually not. Access outline, orifice location, and the removal of a failed restoration are well within a 70 mm field at 4.0×. Negotiating a curved canal, finding a separated file, or judging an isthmus is where the field becomes the constraint and operators move to 5.0× or 6.0×, or to the microscope.\u003c\/p\u003e\n\u003cp\u003eThe comparison with the microscope is not a foregone conclusion. In an ergonomic assessment of 10 operators in endodontics, RULA scores for loupes and microscope were close to each other and both were better than the naked eye (p \u0026lt; 0.001) (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40265995\/\"\u003eInt Endod J 2026;59(6):1102–1109, PMID 40265995\u003c\/a\u003e, checked 2026-11-21). A 4.0× prismatic pair is therefore a defensible instrument for a defined set of procedures, and it is also the natural first prismatic purchase for a clinician who intends to add a higher power later.\u003c\/p\u003e\n\n\u003ch2\u003eWhy does the angled optical path matter for the rest of the day?\u003c\/h2\u003e\n\u003cp\u003eNeck load is cumulative, and the case for an angled design at this power is that it removes the need to trade posture for focus. In a study comparing postural impact across 146 students and 30 dentists, the refractive prismatic design carried the lowest neck-risk score while the Galilean design did not beat the naked eye on that metric (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eJ Dent 2025;163:106162, PMID 41072903\u003c\/a\u003e, checked 2026-11-21). A separate crossover study in dental students found no change in muscle activity or working distance with magnification, although the naked eye showed the larger angular deviation (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40526987\/\"\u003eAppl Ergon 2025;129:104579, PMID 40526987\u003c\/a\u003e, checked 2026-11-21).\u003c\/p\u003e\n\u003cp\u003eWhat none of that supports is the claim that loupes correct an existing injury. The general duty to furnish a workplace free of recognised hazards sits in \u003ca href=\"https:\/\/www.law.cornell.edu\/uscode\/text\/29\/654\"\u003e29 U.S.C. 654(a)(1)\u003c\/a\u003e, and California's repetitive motion injuries rule, \u003ca href=\"https:\/\/www.dir.ca.gov\/title8\/5110.html\"\u003eCal. Code Regs. Title 8, section 5110\u003c\/a\u003e, applies when more than one employee has a physician-diagnosed injury caused predominantly by the job. Loupes are a control measure, not a remedy.\u003c\/p\u003e\n\n\u003ch2\u003eHow do you clean and handle a prismatic pair?\u003c\/h2\u003e\n\u003cp\u003eWipe, do not soak, and never autoclave. Reprocessing instructions published for dental loupes by two established manufacturers exclude immersion disinfection, machine cleaning and disinfection, ultrasonic cleaning and sterilisation, and exclude alcoholic agents on coated optics; alcohol-free cleaning and disinfectant products are specified instead (manufacturer instructions read 2026-11-21). A cemented prism assembly in a sealed barrel is not a repairable item once liquid or heat has been inside it.\u003c\/p\u003e\n\u003cp\u003eFrame and barrels take an alcohol-free wipe between patients, lenses take a microfibre cloth. Contamination of dental magnification loupes has been documented in clinical use (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eJADA 2019;150(8):689–694, PMID 31229256\u003c\/a\u003e, checked 2026-11-21). Note also that loupes are not eye protection: \u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\"\u003e29 CFR 1910.1030(d)(3)(i)\u003c\/a\u003e requires the employer to provide appropriate protective equipment, including eye protection, at no cost, and safety glasses discharge that requirement — loupes are worn with them, not instead of them.\u003c\/p\u003e\n\n\u003ch2\u003eWhere does 4.0x sit in the SOCO ladder?\u003c\/h2\u003e\n\u003cp\u003eFourth of six. The family runs from a wide Galilean 2.5× to a narrow prismatic 6.0×, and the field, depth of field and weight move monotonically as magnification rises — which is why clinicians who work across a range of procedures usually end up with two pairs rather than one compromise.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eMagnification\u003c\/th\u003e\n\u003cth\u003eField of view\u003c\/th\u003e\n\u003cth\u003eWorking distance\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003cth\u003ePupillary distance\u003c\/th\u003e\n\u003cth\u003eHeadlight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE200-25-450\u003c\/td\u003e\n\u003ctd\u003e2.5×, Galilean\u003c\/td\u003e\n\u003ctd\u003e120 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm standard\u003c\/td\u003e\n\u003ctd\u003e60 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE200-35-450\u003c\/td\u003e\n\u003ctd\u003e3.5×, Galilean\u003c\/td\u003e\n\u003ctd\u003e80 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 350–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e72 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE300-40-450 (this page)\u003c\/td\u003e\n\u003ctd\u003e4.0×, prismatic, 45°\u003c\/td\u003e\n\u003ctd\u003e70 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 400–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e65 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE300-50-450\u003c\/td\u003e\n\u003ctd\u003e5.0×, prismatic, 45°\u003c\/td\u003e\n\u003ctd\u003e60 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 400–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e66 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE300-60-450\u003c\/td\u003e\n\u003ctd\u003e6.0×, prismatic, 45°\u003c\/td\u003e\n\u003ctd\u003e50 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 400–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo pairings make sense at this point in the ladder: this 4.0× for the working day with a \u003ca href=\"\/products\/soco-prismatic-dental-loupes-6-0x-450mm\"\u003e6.0× prismatic pair\u003c\/a\u003e for the surgical list, or a \u003ca href=\"\/products\/soco-galilean-dental-loupes-2-5x-450mm\"\u003e2.5× Galilean pair\u003c\/a\u003e for examination and hygiene alongside it. The \u003ca href=\"\/collections\/dental-loupes\"\u003edental loupes collection\u003c\/a\u003e lists the full range, and the \u003ca href=\"\/products\/soco-scml05-wireless-led-dental-headlight\"\u003eSCML05 headlight\u003c\/a\u003e clips to any of these frames.\u003c\/p\u003e\n\n\u003ch2\u003eWhat should a United States buyer confirm before the build?\u003c\/h2\u003e\n\u003cp\u003eThree things: the measured working distance, the pupil distance against the 50–80 mm range, and the shipping terms. For United States addresses, shipping cost and any duties or taxes are shown at checkout, and duties and taxes for United States addresses are prepaid, so the checkout figure is the amount charged with nothing to settle on delivery.\u003c\/p\u003e\n\u003cp\u003eOne tax point that is commonly misapplied at practice level: \u003ca href=\"https:\/\/www.irs.gov\/publications\/p970\"\u003eIRS Publication 970\u003c\/a\u003e counts only course-required equipment as a qualified education expense for students, so a pair bought for a DSO's working operators is a practice purchase rather than a tuition deduction. Buys for several operators are handled through the \u003ca href=\"\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSources, checked 2026-11-21\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/jdh.adha.org\/content\/jdenthyg\/95\/3\/59.full\"\u003eDental magnification loupes and head tilt angles among dental hygiene students and faculty\u003c\/a\u003e, \u003cem\u003eJ Dent Hyg\u003c\/em\u003e 2021, 95(3), 59–64.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eA comparative study of postural impact and benefits from loupes in undergraduate and graduate dentists\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2025, 163, 106162 (PMID 41072903).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40526987\/\"\u003eMagnification of the Galilean system and work posture in dental students: a crossover study\u003c\/a\u003e, \u003cem\u003eAppl Ergon\u003c\/em\u003e 2025, 129, 104579 (PMID 40526987).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29603638\/\"\u003eNear visual acuity of dental hygienists with and without magnification\u003c\/a\u003e, \u003cem\u003eInt J Dent Hyg\u003c\/em\u003e 2018, 16(3), 357–361 (PMID 29603638).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/33000517\/\"\u003eMagnification loupes influence on neck and trunk flexion of dental hygienists while scaling — a pilot study\u003c\/a\u003e, \u003cem\u003eInt J Dent Hyg\u003c\/em\u003e 2021, 19(1), 106–113 (PMID 33000517).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eWork-related musculoskeletal symptoms across the dental training–practice continuum\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2026, 169, 106661 (PMID 41903621).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40265995\/\"\u003eMusculoskeletal risk of first-year postgraduate endodontic students using dental microscope, ergonomic loupes or no magnification\u003c\/a\u003e, \u003cem\u003eInt Endod J\u003c\/em\u003e 2026, 59(6), 1102–1109 (PMID 40265995).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eDisinfection of dental loupes: a pilot study\u003c\/a\u003e, \u003cem\u003eJADA\u003c\/em\u003e 2019, 150(8), 689–694 (PMID 31229256).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42245847\/\"\u003eComparative analysis of dental treatment accuracy using 2.5× magnification loupes versus the naked eye\u003c\/a\u003e, \u003cem\u003eCureus\u003c\/em\u003e 2026, 18(5), e108204 (PMID 42245847).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\"\u003e29 CFR 1910.1030(d)(3)(i)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.law.cornell.edu\/uscode\/text\/29\/654\"\u003e29 U.S.C. 654(a)(1)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.dir.ca.gov\/title8\/5110.html\"\u003eCal. Code Regs. Title 8, section 5110\u003c\/a\u003e, \u003ca href=\"https:\/\/www.irs.gov\/publications\/p970\"\u003eIRS Publication 970\u003c\/a\u003e. All sources checked 2026-11-21.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat ships with the pair\u003c\/h3\u003e\n\u003cp\u003eOne pair of SOCO SCE300-40-450 prismatic loupes at 4.0× with the 45° angled path, built to your measured working distance, pupil distance adjustable across 50–80 mm. Case and cleaning cloth included; the headlight is a separate item.\u003c\/p\u003e\n\n\u003cp class=\"soco-meta\"\u003eDistributed in Canada by CliniEco Medical, Health Canada establishment licence MDEL #35334. Specification values on this page are taken from the product listing and the specification card for SOCO-SCE300-40-450, re-read on 2026-11-21; where a value differs from another surface on this listing, the listing value stands.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- sku-inlink-block:v1 --\u003e\n\u003ch2\u003eRelated sizes and further reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/soco-prismatic-dental-loupes-3-0x-450mm\"\u003eSOCO Prismatic Ergonomic Dental Loupes 3.0x — Angled 45°, 450 mm\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/soco-prismatic-dental-loupes-5-0x-450mm\"\u003eSOCO Prismatic Ergonomic Dental Loupes 5.0x — Angled 45°, 450 mm\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuying guide: \u003ca href=\"\/blogs\/medical-supply-guide\/surgical-loupes-endodontics-implants-oral-surgery\"\u003eSurgical Loupes for Endodontics, Implants and Oral Surgery\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/dental-loupes\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SOCO-SCE300-40-450.jpg?v=1795235339\" alt=\"SOCO Prismatic Ergonomic Dental Loupes 4.0x — Angled 45°, 450 mm — full range\" loading=\"lazy\" width=\"600\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"SOCO","offers":[{"title":"4.0x · Prismatic Ergonomic","offer_id":49481061990622,"sku":"SOCO-SCE300-40-450","price":1249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SOCO-SCE300-40-450.jpg?v=1795235339","url":"https:\/\/clinieco.com\/products\/soco-prismatic-dental-loupes-4-0x-450mm","provider":"CliniEco Medical","version":"1.0","type":"link"}