{"product_id":"petri-dish-100x15mm-sterile-polystyrene-500-case","title":"Sterile Petri Dish 100 × 15 mm — Polystyrene, 500\/Case","description":"\u003cp\u003eCase of 500, supplied sterile and empty, so each lab pours the medium it has already validated. Once a plate has been read it leaves as biohazard waste, which is why the bench set-up usually includes \u003ca href=\"\/products\/clinieco-biohazard-medical-waste-bags-red-30-gallon-leak-proof\"\u003ered 30-gallon biohazard waste bags, 5 per pack\u003c\/a\u003e alongside the dish itself.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/which-sterile-petri-dish-100x15mm-nova-scotia-research-labs\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_main_white_clean_0548b370-1483-457b-9599-53bb889432db.jpg?v=1791271727\" alt=\"Sterile Petri Dish 100 × 15 mm — Polystyrene, 500\/Case\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eWhat is a 100 × 15 mm sterile petri dish used for?\u003c\/h2\u003e\n\u003cp\u003eA 100 × 15 mm petri dish is a round, shallow polystyrene dish measuring 100 mm across and 15 mm deep, supplied sterile and empty so that the laboratory pours a medium it has already validated. The format is two pieces: a base and a loose lid. That is what makes it workable on an open bench — the lid shields the agar surface while the plate is carried and read, and it can be lifted for inoculation without the dish being handled by the agar.\u003c\/p\u003e\n\u003cp\u003eThree kinds of work account for most of the volume a laboratory buys. Colony counts come first: in a pour plate or a spread plate each visible colony is read as one colony-forming unit from the dilution that was plated, so the useful thing about the dish is that it presents a flat, uniformly deep layer of medium that can be counted without parallax. Streak plates for isolation come second: the 100 mm surface divides into enough sectors that a loop can be drawn through successive quadrants and single colonies recovered from the last one. Air and surface sampling come third: a settle plate is left open for a fixed time in a room, and a contact plate is pressed onto a bench or a surface, and both are then incubated and counted the same way as any other plate.\u003c\/p\u003e\n\u003cp\u003eThe 100 mm diameter is the general-purpose size. It fits the stage or carousel of most automatic colony counters, it sits flat inside standard incubator racks and plate towers without overhanging the shelf, and it is the format that the largest number of written procedures name. For a laboratory that runs more than one method, that means one diameter on the shelf instead of several bought for occasional work.\u003c\/p\u003e\n\u003cp\u003eTwo limits are worth stating plainly, because they decide whether this is the right dish at all. It is polystyrene, so it is single use: polystyrene deforms at autoclave temperatures, and glass is the reusable option where a workflow is heat based. And it is sold empty — the medium, the additives and the pouring step belong to the laboratory's own procedure, not to the dish.\u003c\/p\u003e\n\u003ch2\u003eWhat does one 100 × 15 mm plate cost in a case of 500?\u003c\/h2\u003e\n\u003cp\u003eFive hundred dishes to a case is the figure worth carrying into a sampling programme, because a plate count series consumes dishes by the dozen before any incubation time is booked. The case price shown on this listing is the current one; dividing it by 500 gives the per-plate figure, and that arithmetic holds for every method that uses the same 100 × 15 mm format. We keep the amount out of this text on purpose, so that what you read here never falls behind the price you are charged at checkout.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParameter:\u003c\/strong\u003e Detail\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 100 mm diameter × 15 mm height\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polystyrene, optically clear\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLid:\u003c\/strong\u003e Vented, for gas exchange\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSterility state:\u003c\/strong\u003e Sterile, single use\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eStacking:\u003c\/strong\u003e Not designed for stacking (vented lid)\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003e100 × 15 mm sterile dish: specifications and the per-plate arithmetic\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm diameter × 15 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePolystyrene, optically clear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eVented, for gas exchange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility state\u003c\/td\u003e\n\u003ctd\u003eSterile, single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStacking\u003c\/td\u003e\n\u003ctd\u003eNot designed for stacking (vented lid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase configuration\u003c\/td\u003e\n\u003ctd\u003e500 dishes per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended use\u003c\/td\u003e\n\u003ctd\u003eMicrobiological culture work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eCLI-PETRI-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase price\u003c\/td\u003e\n\u003ctd\u003eShown on this listing; one case = 500 dishes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eStandard 100 x 15 mm petri dishes in optically clear polystyrene, supplied sterile in cases of 500. The shallow profile and uniform wall thickness make colony counting and plate photography repeatable between operators.\u003c\/p\u003e\u003cp\u003eSold as empty, sterile dishes — agar and media are not included. That keeps the plate suitable for whichever prepared medium your lab already validates, and avoids the shipment and shelf-life problems that come with pre-poured plates.\u003c\/p\u003e\u003ch2\u003e100 × 15 mm specifications at a glance\u003c\/h2\u003e\n\u003cp\u003eThe table below carries the numbers a method writer or a purchasing officer usually needs before choosing a plate: the diameter, the depth, the surface available for growth, and how much medium it takes to reach a working depth. The growth area and the agar volume are the arithmetic of the format rather than a supplier claim, which is why they are useful when a procedure specifies a pour volume in millilitres instead of a depth in millimetres.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e100 × 15 mm sterile petri dish: specification summary\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePolystyrene, optically clear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility state\u003c\/td\u003e\n\u003ctd\u003eSupplied sterile, single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eVented, for gas exchange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrowth area\u003c\/td\u003e\n\u003ctd\u003eAbout 69 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgar volume at 3 mm depth\u003c\/td\u003e\n\u003ctd\u003eAbout 21 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical pour volume\u003c\/td\u003e\n\u003ctd\u003e15–20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase configuration\u003c\/td\u003e\n\u003ctd\u003e500 dishes per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStacking\u003c\/td\u003e\n\u003ctd\u003eNot designed for stacking (vented lid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended use\u003c\/td\u003e\n\u003ctd\u003eMicrobiological culture work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem code\u003c\/td\u003e\n\u003ctd\u003eCLI-PETRI-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow much agar goes into a 100 × 15 mm dish?\u003c\/h2\u003e\n\u003cp\u003eThe working rule is depth, not volume: a plate is poured to roughly 3 mm of medium, which is deep enough that colonies have room to develop their full shape and shallow enough that light still passes through for counting on a bright background. For a 100 × 15 mm dish the growth surface is about 69 cm², and 69 cm² at 3 mm works out to about 21 mL. In practice most methods pour somewhere between 15 mL and 20 mL, and the plate still reads correctly as long as the layer is even across the whole surface.\u003c\/p\u003e\n\u003cp\u003eWhy the thickness matters more than it sounds. A plate poured too thin dries at the edges during a long incubation, and colonies near the rim stop developing or merge into the drying front, which changes a count without anything being wrong with the sample. A plate poured too thick takes longer to set, holds more condensation under the lid, and puts the colonies further from the surface a counter or a camera is focused on — which matters when two operators read the same plate and are supposed to get the same number.\u003c\/p\u003e\n\u003cp\u003eThe figure is also the easiest way to cost a programme. If a method pours 20 mL per plate, a case of 500 dishes takes about ten litres of prepared medium, and that number belongs in the media-preparation plan next to the plate order rather than being discovered on the day.\u003c\/p\u003e\n\u003cp\u003eWhat the dish does not decide is the medium. Whether the lab pours a general nutrient agar, a selective medium, or a chromogenic one, and what supplements go in, is set by the method being followed and validated; the dish only has to present it at a consistent depth. Plates should be left to set flat on a level surface, and the surface dried to whatever degree the procedure requires before inoculation.\u003c\/p\u003e\n\u003ch2\u003eWhich plate format do routine colony counts actually expect?\u003c\/h2\u003e\n\u003cp\u003e100 × 15 mm is the general-purpose format that most validated methods name for pour plates, spread plates and streak plates: the diameter gives a countable surface without crowding colonies, and the depth leaves room for a poured medium layer. Smaller formats exist for specific methods, so the rule is to match whatever the written procedure specifies rather than substituting. The vented lid allows gas exchange during incubation; keep the dish flat — a vented lid is not designed for stacking, so plates should not be stacked during incubation.\u003c\/p\u003e\n\u003ch2\u003e100 mm vs 90 mm vs 60 mm: which size should a lab order?\u003c\/h2\u003e\n\u003cp\u003eThree diameters cover almost everything a Canadian laboratory buys. The 60 mm (6 cm) dish is the small format: about 23 cm² of growth area, and a pour of roughly 7 mL at 3 mm. It is used where the plate itself is the sample — contact plates and small screening plates — and where the medium is the expensive part of the test, because a small plate spends a fraction of what a full-size plate spends per test. The 90 mm dish is the classic clinical and water laboratory format: about 57 cm² and roughly 17 mL, and the size most established methods were written around. The 100 × 15 mm dish is the larger general-purpose format: about 69 cm² and roughly 21 mL, with the extra surface and depth that routine plate counts and multi-sector streak plates benefit from.\u003c\/p\u003e\n\u003cp\u003eThe decision sequence that saves the most rework is: read the written method first, and order the diameter it names — a procedure validated on one size is not automatically equivalent on another. Then check the physical fit. If the laboratory counts on an automated instrument, the dish has to sit in that instrument's carrier, and the counter's calibration belongs to one diameter. If the incubator is full, stack height and shelf footprint decide how many plates a run can hold, and the difference between a 90 mm and a 100 mm footprint multiplied across a few hundred plates is real shelf space.\u003c\/p\u003e\n\u003cp\u003eAfter that, compare the arithmetic of the test rather than the price of the case. A larger plate carries more medium per test; a smaller plate carries less. Where a sample series needs a countable plate at each dilution, the size that lands the count inside the readable range with the fewest plates per sample is the cheaper one to run, whatever the case costs.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003ePetri dish diameters compared: growth area, agar volume and typical use\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFormat\u003c\/th\u003e\n\u003cth\u003eGrowth area\u003c\/th\u003e\n\u003cth\u003eAgar at 3 mm depth\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 mm (6 cm)\u003c\/td\u003e\n\u003ctd\u003eAbout 23 cm²\u003c\/td\u003e\n\u003ctd\u003eAbout 7 mL\u003c\/td\u003e\n\u003ctd\u003eContact and screening plates, teaching, methods where the medium is the main cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003ctd\u003eAbout 57 cm²\u003c\/td\u003e\n\u003ctd\u003eAbout 17 mL\u003c\/td\u003e\n\u003ctd\u003eEstablished clinical and water methods written around this size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 × 15 mm\u003c\/td\u003e\n\u003ctd\u003eAbout 69 cm²\u003c\/td\u003e\n\u003ctd\u003eAbout 21 mL\u003c\/td\u003e\n\u003ctd\u003eRoutine plate counts, multi-sector streak plates, environmental sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOne practical note on mixing formats: if a laboratory keeps two diameters, the incubator, the counter and the media plan all have to handle both, and the labels have to say which is which. Standardising on one diameter for the routine work and buying the other only for the specific method it belongs to is usually the cheaper arrangement.\u003c\/p\u003e\n\u003ch2\u003eVented or non-vented: which lid for which work?\u003c\/h2\u003e\n\u003cp\u003eA vented lid has small gaps or raised ribs that let air move between the inside of the dish and the incubator, and that single feature decides most of the choice. Gas exchange keeps the atmosphere in the dish close to the atmosphere in the incubator, and it lets condensation escape instead of pooling on the lid and dripping onto the agar when the plate is moved or inverted.\u003c\/p\u003e\n\u003cp\u003eA non-vented lid closes that exchange down. That is what a slow-growing organism or a long incubation wants, because the plate does not dry out at the same rate, and it is what a sealed or wrapped plate needs when the point is to hold a modified atmosphere. It is also the safer choice whenever a plate leaves the building, because a plate in transit is a plate that can leak.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eLid choice by working situation\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSituation\u003c\/th\u003e\n\u003cth\u003eLid\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort incubation with daily reading\u003c\/td\u003e\n\u003ctd\u003eVented\u003c\/td\u003e\n\u003ctd\u003eGas exchange, less condensation on the lid, plates can be read without wiping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong incubation or slow-growing organisms\u003c\/td\u003e\n\u003ctd\u003eNon-vented, or vented and sealed once inoculated\u003c\/td\u003e\n\u003ctd\u003eSlows drying, holds humidity across the run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport or send-out to another site\u003c\/td\u003e\n\u003ctd\u003eNon-vented, bagged\u003c\/td\u003e\n\u003ctd\u003eContainment in transit, no leaking through vents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared incubator used by several people\u003c\/td\u003e\n\u003ctd\u003eVented, as the procedure states\u003c\/td\u003e\n\u003ctd\u003eConsistent atmosphere for every plate in the run, and the usual arrangement where plates are opened during reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork that needs a modified atmosphere\u003c\/td\u003e\n\u003ctd\u003eNon-vented, sealed with a gas-generating system\u003c\/td\u003e\n\u003ctd\u003eThe seal is what keeps the atmosphere in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe dish on this listing has a vented lid, which is the arrangement routine plate counts and streak plates are normally run with. Where a method calls for a sealed plate, the seal is applied after inoculation and the vent then stops mattering — the plate behaves as a closed vessel from that point on.\u003c\/p\u003e\n\u003ch2\u003eHow do you keep plates sterile in storage, and how are they disposed of?\u003c\/h2\u003e\n\u003cp\u003eKeep the sleeve closed until the plate is needed, work from one sleeve at a time, and never return an opened plate to the sleeve — a lid that has been off on a bench is no longer sterile, and the medium will show it. These dishes are polystyrene and single use: they deform in an autoclave, so glass is the reusable option if the workflow is heat-based. After reading, plates go into the biohazard waste stream rather than general refuse, sealed in the bag the waste carrier accepts.\u003c\/p\u003e\n\u003cp\u003ePlate and consumable volumes for a sampling programme can be modelled on the \u003ca href=\"\/pages\/clinic-supply-planner\"\u003esampling programme planner\u003c\/a\u003e; \u003ca href=\"\/pages\/compliance-log-center\"\u003eculture and media-preparation templates\u003c\/a\u003e print from the compliance log centre, which also carries the sterilization log generator for the reusable glassware side. Laboratory and multi-site volumes are quoted at \u003ca href=\"\/pages\/wholesale\"\u003eour clinic ordering desk\u003c\/a\u003e, and method or documentation questions can be raised with the \u003ca href=\"\/pages\/sterilization-compliance-consultation\"\u003ecompliance desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eCliniEco Medical brings this dish into Canada under MDEL #35334, and lot documentation is available with the case.\u003c\/p\u003e\n\n\n\u003ch2\u003eHow should plates be labelled, stored and incubated?\u003c\/h2\u003e\n\u003cp\u003eLabel the base, not the lid. Lids get swapped between plates on a busy bench, and a plate whose identity lives on the lid is a plate that can be counted against the wrong sample. A workable minimum is the date poured, the medium, the sample identifier and dilution, and the initials of the person who poured or plated it — written on the base with a marker that survives the incubator and, if the plate is stored, the fridge.\u003c\/p\u003e\n\u003cp\u003ePrepared plates are stored inverted at 2–8 °C, in their sleeve or a sealed bag, and brought back to room temperature before use so that condensation does not form on the agar when the lid comes off. Inverting them in storage keeps any condensation that does form on the lid rather than on the medium. First in, first out: the oldest sleeve is used first, and the date on the base is what decides which one that is.\u003c\/p\u003e\n\u003cp\u003eIncubation is inverted as well, for the same reason — a plate that sits lid-up collects water on the inside of the lid, and when it is moved to a counter that water lands on the agar and smears colonies together. The temperature is whatever the method names; clinical work is commonly run near body temperature, environmental and food work at lower temperatures over a longer period, and the number in the procedure is the one that applies rather than a general figure.\u003c\/p\u003e\n\u003cp\u003eReading and recording: count from the underside against a suitable background, note the dilution, and record anything that made the plate hard to read — a drying edge, a spreading colony, an obvious contaminant. Plates with contamination are recorded rather than quietly discarded, because a run of contaminated plates is a signal about technique or about the incubator. After reading, the plate is biohazard waste: it goes into the waste stream the receiving carrier accepts, sealed, not into general refuse.\u003c\/p\u003e\n\u003cp\u003eNone of the above replaces local procedure. Handling, storage limits and record retention are set by the laboratory's own standard operating procedure and by provincial requirements, and those take precedence over any general guidance on a product page.\u003c\/p\u003e\n\u003ch2\u003eWhat documentation should come with a case?\u003c\/h2\u003e\n\u003cp\u003eTraceability starts with the lot number. The case and its inner sleeves carry a lot reference from the manufacturer, and that reference is what links a plate on a bench back to the batch it came from — which is the question that gets asked when a count looks wrong, or when an auditor wants to know what was used on a given date. Record the lot number when the case is opened and keep it with the plate records rather than leaving it on the carton.\u003c\/p\u003e\n\u003cp\u003eFor the batch documentation itself — the sterilization information and the lot record issued for that batch — ask us and we will pass on what the manufacturer provides for the lot you received. That is a request per batch, not a certificate that ships inside every case, so if your quality system requires a document on file before use, raise it when the order is placed and keep the reply with the batch record.\u003c\/p\u003e\n\u003cp\u003eOn arrival, three checks are worth doing before the case goes on the shelf: the number of cases and sleeves against the packing document, the condition of the cartons and of the sleeve seals, and whether the lot reference on the cartons matches the lot reference on the sleeves inside. A damaged sleeve is a plate that is no longer sterile; it should be set aside and reported rather than pushed to the back of the shelf.\u003c\/p\u003e\n\u003cp\u003eWhere a laboratory is accredited or audited, the plate supplier is part of the record: the item code, the lot, and the date received are the three fields an auditor is most likely to ask for, and all three are on the carton when it arrives.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFood and beverage plant microbiology labs running routine plate counts\u003c\/li\u003e\n\u003cli\u003eEnvironmental and water testing laboratories\u003c\/li\u003e\n\u003cli\u003eSchool, college and university teaching labs\u003c\/li\u003e\n\u003cli\u003eCompounding pharmacies and clinics performing sterility checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow many cases should a lab order at a time?\u003c\/h2\u003e\n\u003cp\u003eWork from weekly usage, not from the case size. One case holds 500 dishes, so a laboratory that plates 100 dishes a week is holding about five weeks of supply in a single case; at 250 a week the same case lasts a little over one week. That arithmetic is the whole calculation, and it is worth doing once because the answer decides both how often the order is placed and how much shelf space the plates occupy.\u003c\/p\u003e\n\u003cp\u003eTwo things pull in opposite directions. Ordering too little means a run is delayed for want of a plate, which is the failure mode that costs the most because the sample is already in hand. Ordering too much means sleeves sit at the back of a shelf for months, in a stack that gets moved and squeezed every time something is taken out — and polystyrene sleeves that have been handled repeatedly are not the ones to trust for a critical count. A stock level of roughly four to six weeks of use, reviewed against actual usage rather than the original estimate, is the usual compromise.\u003c\/p\u003e\n\u003cp\u003eStorage is part of the same decision: plates are kept in their original sleeves, in a dry place, off the floor, and rotated so the oldest sleeve is used first. Where the laboratory runs more than one method, the case count per method should be sized separately, because the methods rarely consume plates at the same rate.\u003c\/p\u003e\n\u003cp\u003eFor laboratories and multi-site groups placing standing orders, the case size is also the unit that makes the paperwork simple: 500 per case means quantities are whole cases rather than part sleeves, and a purchase order can be written in the same unit the shelf is stocked in.\u003c\/p\u003e\n\u003ch2\u003eOrdering and compliance notes\u003c\/h2\u003e\n\u003cp\u003ePair with inoculating loops, spreaders and colony counters for a complete bench set-up. If your workflow uses pre-poured or pre-prepared plates with agar, that is a separate product family with its own supply and regulatory treatment.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/food-plant-microbiology-lab-starter-supply-checklist\"\u003eFood plant microbiology lab: starter supply checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/usp-71-sterility-testing-explained-what-pharmacies-and-compounding-labs-need-to-know\"\u003eUSP 71 sterility testing explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/your-food-plants-microbiology-lab-sampling-sterilization-verification-and-record-keeping\"\u003eMicrobiology lab: sampling, verification and record-keeping\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/sterile-petri-dishes-handling-labelling-and-incubation-basics\"\u003eSterile petri dishes: handling, labelling and incubation basics\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/petri-dish-sizes-canadian-labs-bulk-ordering-case-counts\"\u003ePetri dish sizes for Canadian labs: bulk ordering and case counts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/vented-vs-non-vented-petri-dishes-for-clinic-labs\"\u003eVented vs non-vented petri dishes for clinic laboratories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuying for a clinic, lab or care home?\u003c\/strong\u003e Order the case size online, or request a B2B quote for volume pricing, standing orders and purchase-order terms at \u003ca href=\"\/pages\/wholesale\"\u003eCliniEco bulk quote\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/where-to-buy-sterile-petri-dish-100x15mm-saskatchewan-labs\"\u003eWhere to Buy Sterile Petri Dish 100 × 15 mm for Diagnostic Laboratories in Saskatchewan\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49039185969374,"sku":"CLI-PETRI-100","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_main_white_clean_0548b370-1483-457b-9599-53bb889432db.jpg?v=1791271727","url":"https:\/\/clinieco.com\/products\/petri-dish-100x15mm-sterile-polystyrene-500-case","provider":"CliniEco Medical","version":"1.0","type":"link"}