{"product_id":"clinieco-ultrasonic-cleaner-cd4875-7-5l-dental","title":"CliniEco Dental Ultrasonic Cleaner — CD-4875, 7.5 L Benchtop with Heating","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e 7.5 L nominal, 6,000 ml working volume, 35 kHz and 380 W, with the same five temperature presets as the 6 L unit — more room in the tank, the same size of usable load.\u003c\/p\u003e\n\n\u003cp\u003eThis is the awkward row in any ultrasonic range, and it is worth being precise about why. A 7.5 L tank (7,500 ml, or 2.0 US gallons) has a 6,000 ml working volume, which is the same usable load as the 6 L class. What the extra shell buys is headroom: longer trays fit, splashing stays inside the tank, and the unit does not have to be filled to its limit. It does not buy a second cassette.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CD-4875 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eRead the working volume row before the capacity row. Between 6 L and 7.5 L the nominal figure moves and the usable figure does not, which is exactly the sort of detail that decides a purchase.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volume\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 35 kHz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 380 W, AC 100–120 V, 60 Hz, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e 1 to 30 minutes\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHeating:\u003c\/strong\u003e Five presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety features:\u003c\/strong\u003e Dual heating protection, moisture-resistant PCB, detachable power cord\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCD-4875 — 7.5 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volume\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e33.1 × 23.8 × 10.5 cm (length × width × depth), SUS304 stainless steel tank\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 W, AC 100–120 V, 60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFive presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual heating protection, moisture-resistant PCB, detachable power cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDrain valve fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 220112139GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty; stainless basket available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CD-4875 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CD-4875 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eIf a cassette is the unit of work in your practice, the choice is 6 L or 20 L, and this size sits between them for a different reason: it gives the same 6,000 ml working load with more freeboard in the tank.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental\"\u003eCD-4862\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCD-4875\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop\"\u003eCS8.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench\"\u003eCS20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe practical case for this size is a bench where trays rather than cassettes are loaded — implant trays, orthodontic pliers laid out in a line, a row of handpieces that do not fit a cassette. Measure the tray first; if it fits with 2 cm to spare, this is the tank that stops the splashing.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CD-4875?\u003c\/h2\u003e\n\n\u003cp\u003eWith more freeboard than the 6 L unit, this tank tolerates a tray that sits proud of the liquid line better than a brim-full smaller tank — but not a tray that is only half submerged. Load, then check the level.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003eTo 6,000 ml working volume with solution at the label dilution\u003c\/td\u003e\n\u003ctd\u003eThe 7.5 L figure is the shell, not the dose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Preset\u003c\/td\u003e\n\u003ctd\u003e40, 45, 50, 55 or 60 °C — matched to the solution label\u003c\/td\u003e\n\u003ctd\u003eEnzymes have a working window; the preset keeps you inside it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eTray or basket, items separated, hollow instruments flooded\u003c\/td\u003e\n\u003ctd\u003eTrapped air is the most common reason a lumen does not clean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Time\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes, set to the interval your protocol names\u003c\/td\u003e\n\u003ctd\u003eA number on the log, not an approximation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eEmpty through the valve, dry the chamber, log the cycle\u003c\/td\u003e\n\u003ctd\u003eThe record is the deliverable an inspection asks for\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eBecause the usable volume is 6,000 ml whatever the shell says, the dose of solution is the same as a 6 L unit. Buying the larger tank does not mean buying more concentrate per cycle, and a log that records a larger dose than the label ratio is the kind of small inconsistency an auditor notices.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThe CD-4875 is covered by Intertek report 220112139GZU-001 — the same report family as the CS units — rather than the 210716104GZU-001 report that covers the 6 L CD-4862. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 220112139GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 7.5 L, 110 V with a North American plug and the manufacturer warranty. Basket as an accessory. The detachable cord and the drain valve are the two features that make end-of-day cleaning quick.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eThe 7.5 L unit sits between the cassette tank and the 8 L bench unit, and the difference shows up in the fill arithmetic: roughly 19 mL of concentrate per full tank at 1:400, and just over fifty fills from a 1 L bottle. Clinics that run longer trays and change the bath once a day will see a pail pay for itself in handling time long before it pays for itself in chemistry.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4875 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (7.5 L nominal capacity)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 18.8 mL\u003c\/td\u003e\n\u003ctd\u003e53 fills\u003c\/td\u003e\n\u003ctd\u003e266 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 12.5 mL\u003c\/td\u003e\n\u003ctd\u003e80 fills\u003c\/td\u003e\n\u003ctd\u003e400 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 53 fills is roughly 11 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eThe tank is dosed with the \u003ca href=\"\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e, packed as 1 L or 5 L, diluted 1:400 to 1:600 in water. Low-foam formulation, working temperature 20–50 °C, cycle 2 to 10 minutes, 24 months sealed shelf life and 90 days after opening — all of it printed on the label that comes with the pack.\u003c\/p\u003e\n\u003cp\u003eThe cleaner does not decide when the bath is spent; the label and your protocol do. What this unit adds is a drain valve, so the bath is emptied through the valve instead of being lifted out, and the change goes into the record in the same minute. Ontario guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, retained \u003cem\u003eaccording to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4875 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eLonger trays mean more shielding between instruments, so load discipline matters as much as chemistry: joints open, instruments not stacked, and the tray not resting directly on the tank floor where the transducer field is strongest and least even.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003eChoosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaning-vs-manual-scrubbing-order\"\u003eUltrasonic Cleaning vs Manual Scrubbing: Correct Order in Instrument Reprocessing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaning-baths-how-to-verify\"\u003eUltrasonic Cleaning Baths: How Do You Verify They Work?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376920174814,"sku":"CLI-ULTRA-CLEAN-CD4875","price":609.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CD-4875-HERO-logo-20261110_95a68414-ed9b-4ea0-bfc9-e2ad0f6c58f1_b6f233cc-8c14-46e8-a59c-34f33f169f18.jpg?v=1794344560","url":"https:\/\/clinieco.com\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental","provider":"CliniEco Medical","version":"1.0","type":"link"}