{"product_id":"clinieco-medical-steam-chemical-integrator-class-5-iso-11140-1-type-5-100-pack","title":"CliniEco Medical Steam Chemical Integrator — Class 5, ISO 11140-1 Type 5 | 200 \u0026 1,000 Strip Packs","description":"\u003ch2\u003eCliniEco Medical Steam Chemical Integrator — Class 5, ISO 11140-1 Type 5\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eISO 11140-1 Type 5 integrating indicator for steam sterilization — 200 or 1,000 strips per pack, 121–135 °C, yellow-to-black read.\u003c\/strong\u003e An integrating indicator responds to time, temperature and saturated steam in a single pass\/fail window, so every pouch, bag or tray carries its own in-pack check and a load can be released the same day without waiting on an incubation result. It supplements — and does not replace — the biological indicator used in your daily spore test. Supplied by CliniEco Medical, Health Canada licensed importer and distributor (MDEL #35334), with a lot-level CoA available on request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClass 5 Indicators for Sterilization.\u003c\/strong\u003e If that is the search that brought you here, this is the strip it refers to: a Class 5 Chemical Indicator in ISO 11140-1 Type 5 form, read inside the pack rather than printed on the outside of it, so the pass window belongs to that one pouch, bag or tray. It is supplied as a 200-strip pack, and as a case of 5 × 200 for clinics that keep a working pack on the shelf and the rest in stores.\u003c\/p\u003e\n\u003cdiv style=\"background:#f0f7f2;border:2px solid #123a2f;border-radius:8px;padding:10px 14px;margin:14px 0;\"\u003e\n\u003ch2\u003eHow to use the integrator\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlace one in every pack.\u003c\/strong\u003e Put a single integrator inside each pouch, bag or tray before it is sealed. In a rigid container, place one in each corner — or at least two diagonally opposite corners — so the strip reads the path steam actually took.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad and run a validated steam cycle.\u003c\/strong\u003e The strip is formulated for 121–135 °C and reads gravity, pre-vacuum and immediate-use cycles; use it inside the cycle your sterilizer is validated for, not as a substitute for that validation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead it straight out of the chamber.\u003c\/strong\u003e The ink front must travel into the ACCEPT window and match the black reference on the strip. A front that stops short is a reject: hold the load, do not release it, and re-run the cycle after the cause is corrected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord the result before the load leaves.\u003c\/strong\u003e Enter the date, sterilizer ID, cycle number and pass\/fail on the load log, and file the strip with that record — an inspector reads the log and the strips together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep the biological indicator schedule.\u003c\/strong\u003e A Type 5 strip releases the load; it does not replace the spore test. Daily (or per your provincial requirement) biological indicator monitoring continues unchanged.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 style=\"margin:0;color:#123a2f;\"\u003eCliniEco Service Promise\u003c\/h3\u003e\n\u003cul style=\"margin:8px 0 0;padding-left:18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree shipping over $99 in Ontario · $199 rest of Canada (Ontario) \/ $199 (rest of Canada)\u003c\/strong\u003e (Ontario)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrders dispatched within 24h\u003c\/strong\u003e (Toronto)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCanadian-owned company\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/class-5-steam-chemical-integrator-reading-window-pack-counts-load-release\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/INTEGRATOR-HERO-noqty-20261110_109ae31e-c8ee-475e-9b87-f16f1e87b917.jpg?v=1794348315\" alt=\"CliniEco Medical Steam Chemical Integrator — Class 5, ISO 11140-1 Type 5\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eWhat is an ISO 11140-1 Type 5 integrator, and how does it differ from tape or a Class 4 indicator?\u003c\/h2\u003e\n\u003cp\u003eISO 11140-1 sorts chemical indicators by what they measure. Class 1 is a process indicator such as autoclave tape, which only shows that a pack went through a cycle. Class 3 responds to a single variable and Class 4 to two or more. Class 5 — Type 5 in the standard's own numbering — is the integrating indicator: time, temperature and saturated steam are read together in one window, and the strip is designed so that an accept result corresponds to the lethality a biological indicator would demonstrate in the same cycle. That is the practical difference from a Class 4: a Class 4 tells you more than one variable was present, while a Type 5 is calibrated to stand in for the outcome.\u003c\/p\u003e\n\n\u003ch2\u003eDoes a Type 5 strip replace the biological indicator?\u003c\/h2\u003e\n\u003cp\u003eNo, and treating it that way is the mistake the classification exists to prevent. An integrator is an in-pack check that can run on every load, which is what a biological indicator cannot economically do. A spore test answers a different question — did the cycle actually kill organisms — and is run on a schedule, plus for every load containing implants. If you are setting the frequency for your own sterilizers, \u003ca href=\"\/pages\/sterilization-compliance-consultation\"\u003eask a sterilization compliance specialist\u003c\/a\u003e what your college expects rather than copying another clinic's schedule, and pair the strips with a \u003ca href=\"\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour biological indicator\u003c\/a\u003e for the periodic test.\u003c\/p\u003e\n\n\u003ch2\u003eHow many strips does a year of loads use, and what does it cost?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eOrder\u003c\/th\u003e\n\u003cth\u003eStrips\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\/pack\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e$17.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase of 5 × 200 · 1,000\u003c\/td\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003ctd\u003e$79.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOne strip per pack is the point of the product, so the count follows the pack count. Twenty packs a day over 240 working days is 4,800 strips: twenty-four packs of 200, or just under five cases of 1,000. Each of the two order formats is priced on this page, and the per-strip figure follows from each pack amount by dividing; the case works out lowest per strip, and the 200\/pack sits between the two — the sensible middle for a clinic that does not want a thousand strips on the shelf at once.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cycles will a Type 5 strip read?\u003c\/h2\u003e\n\u003cp\u003eThe page specifies 121°C to 135°C, covering gravity-displacement, pre-vacuum and immediate-use cycles. What changes between them is the time and the air removal, and the strip is built to respond across that band rather than to a single set point — which is why one SKU can serve a clinic with a gravity sterilizer in one room and a pre-vacuum unit in another. It does not make the strip a substitute for the daily air-removal test on the pre-vacuum machine: that is still a \u003ca href=\"\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eBowie-Dick pack, ISO 11140-5 Type 2\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eHow is the strip read and written up?\u003c\/h2\u003e\n\u003cp\u003eRead the moving front against the printed accept and reject zones after the cycle has finished, once the pack is cool enough to handle — the ink front is still travelling while the pack is hot, and a window read mid-move is not a reading. Then write it down: strip lot, cycle number, sterilizer ID, date and result. \u003ca href=\"\/pages\/compliance-log-center\"\u003ePrint the load record sheet\u003c\/a\u003e or build one with the \u003ca href=\"\/pages\/compliance-log-center\"\u003elog generator\u003c\/a\u003e so the strip result and the pack contents sit on the same line. Store the box sealed and away from heat, and keep the lot number from the box for the record.\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#123a2f;color:#fff;\"\u003e\n\u003cth style=\"padding:6px;text-align:left;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"padding:6px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f7f9f8;\"\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eProduct\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eSteam Chemical Integrator (Chemical Indicator, Class 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eStandard\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eISO 11140-1:2014 — Type 5 integrating indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f9f8;\"\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eStrip Size\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003e2″ × 0.75″ (50 × 19 mm) standard; extended-length option available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003ePack Size\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003e200 strips \/ pack · 1,000 strips \/ case (5 × 200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f9f8;\"\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eParameters Monitored\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eTime + temperature + saturated steam penetration (multi-parameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eCycle Compatibility\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003e121–135°C steam sterilization — gravity, pre-vacuum and immediate-use (IUSS) cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f9f8;\"\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eReadout\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eMoving-front window: ink migrates from REJECT to ACCEPT zone when all parameters are met\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eResult\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eImmediate pass\/fail — no incubation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f9f8;\"\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eShelf Life\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eSee the expiry date printed on each pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eIntended Use\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eIn-pack monitoring for dental, veterinary, laboratory and medical facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f9f8;\"\u003e\n\u003ctd style=\"padding:6px;\"\u003e\u003cb\u003eDistribution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eCliniEco MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e✓ \u003cstrong\u003eA same-day, in-pack read for every load\u003c\/strong\u003e — the strip responds across 121 °C, 128 °C and 135 °C, so a load can be released or held without waiting on an incubation result. \u003cstrong\u003eIt does not replace a biological indicator\u003c\/strong\u003e: periodic spore testing still applies.\u003c\/li\u003e\n\u003cli\u003e✓ \u003cstrong\u003eThree critical parameters in one strip\u003c\/strong\u003e — time, temperature and saturated steam; a single ink front confirms all were met\u003c\/li\u003e\n\u003cli\u003e✓ \u003cstrong\u003eUnambiguous pass\/fail window\u003c\/strong\u003e — dark bar must enter the ACCEPT zone; eliminates guesswork compared with single-parameter Class 1–4 indicators\u003c\/li\u003e\n\u003cli\u003e✓ \u003cstrong\u003eLaminated construction\u003c\/strong\u003e — plastic-coated strip resists moisture and handling damage inside the pack\u003c\/li\u003e\n\u003cli\u003e✓ \u003cstrong\u003ePlace inside every pack or tray\u003c\/strong\u003e — use with sterilizer trays, cassettes, wrapped packs and peel pouches\u003c\/li\u003e\n\u003cli\u003e✓ \u003cstrong\u003eNo equipment lock-in\u003c\/strong\u003e — works with any steam autoclave; no reader or incubator required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQuality \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eISO 11140-1:2014 Type 5 (third-party tested)\u003c\/li\u003e\n\u003cli\u003eDistributed by CliniEco Medical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClinic \u0026amp; Volume Pricing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVolume pricing is available on request — contact alina@clinieco.ca.\u003c\/li\u003e\n\u003cli\u003eFree shipping over $99 in Ontario · $199 rest of Canada (Ontario) \/ $199 (rest of Canada)\u003c\/li\u003e\n\u003cli\u003eNo minimum order — buy 1 box or a case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Clinics Choose CliniEco\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower cost per strip than 3M\/Crosstex integrators\u003c\/strong\u003e at comparable Type 5 performance — confirm each supplier's current list pricing before you compare\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-direct pricing\u003c\/strong\u003e — no distributor mark-ups\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne supplier for the full sterilization line\u003c\/strong\u003e — pouches, rolls, tape, indicators, biological indicators and BD test packs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClinic \u0026amp; Volume Orders\u003c\/h3\u003e\n\u003cp\u003eLooking for 500-strip bags, private-label branding or standing monthly volume? Contact us for pallet pricing and priority restocking: \u003ca href=\"\/pages\/wholesale\"\u003eRequest a B2B Quote\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003e💡 Pair It With Your Sterilization Routine\u003c\/h3\u003e\n\u003cp\u003eCombine with \u003ca href=\"\/products\/clinieco-medical-sterilization-pouch-class-4-dual-indicator-assorted-sizes-200\/pack\"\u003eCliniEco Sterilization Pouches\u003c\/a\u003e, \u003ca href=\"\/products\/clinieco-medical-autoclave-tape-sterilization-indicator-tape-3-roll-set\"\u003eAutoclave Tape\u003c\/a\u003e and \u003ca href=\"\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eBiological Indicators\u003c\/a\u003e to cover every load — or explore the full \u003ca href=\"\/collections\/sterilization-monitoring\"\u003eSterilization Monitoring\u003c\/a\u003e collection.\u003c\/p\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/iso-15882-chemical-indicator-selection-storage-reading\"\u003eISO 15882 in Practice: Selecting, Storing and Reading Chemical Indicators\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/how-do-i-know-if-my-autoclave-is-working-properly\"\u003eHow do I know if my autoclave is working properly?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/chemical-indicator-strips-price-canada-cost-per-pack\"\u003eChemical Indicator Strips Price in Canada: What Drives Cost per Pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/chemical-indicators-class-4-vs-5-vs-6-which-canadian-clinics-order\"\u003eChemical Indicators Class 4 vs Class 5 vs Class 6: Which Do Canadian Clinics Order\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- ce:sub-link-20261116 --\u003e\u003cp\u003eA set quantity of integrators every month, with the biological indicators and Bowie-Dick tests that go with them: \u003ca href=\"\/products\/clinieco-sterilization-subscription\"\u003ea fixed monthly quantity of Class 5 integrators\u003c\/a\u003e in one pack.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Case of 5 × 200 · 1,000","offer_id":49040461037790,"sku":"CLI-STER-CI-100-CASE10","price":57.0,"currency_code":"USD","in_stock":true},{"title":"200\/pack","offer_id":49043182911710,"sku":"CLI-CI5-200","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/INTEGRATOR-HERO-200pack-20261110.jpg?v=1794776853","url":"https:\/\/clinieco.com\/products\/clinieco-medical-steam-chemical-integrator-class-5-iso-11140-1-type-5-100-pack","provider":"CliniEco Medical","version":"1.0","type":"link"}