{"product_id":"clinieco-galilean-flip-up-dental-loupes-4x","title":"CliniEco Galilean Flip-Up Dental Loupes — 4× Magnification, Adjustable, Lightweight","description":"\u003cstyle\u003e\n.loupe-prod{max-width:780px;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,sans-serif;color:#111827;line-height:1.65;font-size:16px}\n.loupe-prod h2{font-size:20px;color:#123a2f;border-bottom:2px solid #E5E7EB;padding-bottom:8px;margin:32px 0 12px}\n.loupe-prod h3{font-size:17px;color:#206270;margin:24px 0 8px}\n.loupe-prod p{margin:0 0 12px}\n.loupe-prod ul{margin:0 0 14px;padding-left:20px}\n.loupe-prod li{margin-bottom:8px}\n.loupe-prod img{max-width:100%;height:auto;border-radius:10px;display:block;margin:14px 0}\n.loupe-prod table{width:100%;border-collapse:collapse;margin:14px 0;font-size:14.5px}\n.loupe-prod th{background:#123a2f;color:#ffffff;text-align:left;padding:10px 12px;border:1px solid #123a2f;font-weight:600}\n.loupe-prod td{border:1px solid #E5E7EB;padding:10px 12px;vertical-align:text-top}\n.loupe-prod tbody td:first-child{background:#F9FAFB;font-weight:600}\n.loupe-note{background:#FFF7ED;border:1px solid #FDBA74;border-radius:8px;padding:14px 16px;font-size:14.5px;color:#7C2D12;margin:16px 0}\n.loupe-meta{font-size:14px;color:#4B5563}\n@media (max-width:600px){.loupe-prod{font-size:15.5px}.loupe-prod h2{font-size:18px}.loupe-prod table{font-size:13.5px}.loupe-prod th,.loupe-prod td{padding:8px 9px}}\n\u003c\/style\u003e\n\u003cdiv class=\"loupe-prod\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eCliniEco Galilean flip-up dental loupes at 4× publish a 70–75 mm field at 65 g, sit above the 3.5× pair in power and below the prism pairs in cost of ownership, and suit clinicians who want more margin detail without moving to prism optics.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CliniEco Galilean flip-up loupes at 4×?\u003c\/h2\u003e\n\u003cp\u003eModel CLI-LOUPE-40 is a Galilean pair — two lens elements per barrel — on a flip-up frame with adjustable interpupillary distance and adjustable declination. The working distance is one of four groups chosen when the pair is built: 280–380 mm, 360–460 mm, 440–540 mm or 500–600 mm. Published field of view is 70–75 mm nominal and published weight is 65 g with the frame, both as they appear on this listing on 2026-11-22.\u003c\/p\u003e\n\u003cp\u003eIt is the heaviest and the most powerful of the Galilean flip-up pairs in our range, and the two facts are related: the barrels are longer than the low-power ones, and the mounting hardware carries that extra length further forward on the frame than a 2.5× pair does.\u003c\/p\u003e\n\n\u003ch2\u003eIs 4× a worthwhile step up from 3.5×?\u003c\/h2\u003e\n\u003cp\u003eThat depends on which number you are stepping toward, and this is the page where the published figures have to be read carefully rather than assumed.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePair\u003c\/th\u003e\n\u003cth\u003ePublished field\u003c\/th\u003e\n\u003cth\u003ePublished weight\u003c\/th\u003e\n\u003cth\u003eField area relative to 4×\u003c\/th\u003e\n\u003cth\u003eWhat changes for the wearer\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalilean 3.0×\u003c\/td\u003e\n\u003ctd\u003e75–85 mm\u003c\/td\u003e\n\u003ctd\u003e46 g with the frame\u003c\/td\u003e\n\u003ctd\u003e1.2×\u003c\/td\u003e\n\u003ctd\u003eWider, lighter, less detail at the margin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalilean 3.5×\u003c\/td\u003e\n\u003ctd\u003e60–65 mm\u003c\/td\u003e\n\u003ctd\u003e47 g with the frame\u003c\/td\u003e\n\u003ctd\u003e0.7×\u003c\/td\u003e\n\u003ctd\u003eNarrower and lighter than this 4×, with nothing else changed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalilean 4× (this pair)\u003c\/td\u003e\n\u003ctd\u003e70–75 mm\u003c\/td\u003e\n\u003ctd\u003e65 g with the frame\u003c\/td\u003e\n\u003ctd\u003e1.0×\u003c\/td\u003e\n\u003ctd\u003eMore power, a wider published field than the 3.5×, and 18 g more on the frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"loupe-meta\"\u003eField area = (other midpoint \/ 72.5 mm)². Every value above is quoted from that model's own listing on 2026-11-22. The published 4× field is wider than the published 3.5× field even though the power is higher, which is the opposite of the usual direction; we report both as published rather than reconcile them on a product page, and if the choice between the two turns on field, ask us to confirm against each specification card before ordering.\u003c\/p\u003e\n\u003cp\u003eSo the honest answer is yes if you want more power and can accept 65 g on the frame; and no if what you actually wanted was more field, because the 3.0× pair publishes 75–85 mm at 46 g. The step that is hard to justify is 3.5× to 4× when field was the reason for looking.\u003c\/p\u003e\n\n\u003ch2\u003eWhy is the 4× pair heavier than the 3.0×, and does the extra mass matter?\u003c\/h2\u003e\n\u003cp\u003eMore power in a Galilean barrel means a longer barrel, and a longer barrel means more mass forward of the frame. The published figures in our range run 42 g at 2.5×, 46 g at 3.0×, 47 g at 3.5× and 65 g at 4× — each from its own listing — so this pair carries about 40 percent more mass than the 3.0×.\u003c\/p\u003e\n\u003cp\u003eWhether 19 g matters is a question about flips, not about physics. A pair that is flipped up and down twenty times a day with a heavy front end drifts unless the hinge holds its position, and the first symptom of drift is a slightly softer image rather than a loose frame. If you are choosing between this pair and a 3.5× on comfort grounds, the deciding question is how often you flip during a procedure, not how long you wear it.\u003c\/p\u003e\n\u003cp\u003eThe published material on posture makes the same point from the other direction: in a comparison of 146 undergraduate and graduate dentists, the refractive prismatic design carried the lowest neck-risk score, the Galilean design did not beat the naked eye on that metric, and knowledge of how to select a loupe was incomplete in both groups (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eJ Dent 2025;163:106162, PMID 41072903\u003c\/a\u003e, checked 2026-11-22). Mass alone does not decide whether a pair helps your neck; getting the working distance and the declination right does, and both are adjustable decisions taken before and after the order.\u003c\/p\u003e\n\n\u003ch2\u003eHow does 4× Galilean compare with the 5× and 6× prism pairs?\u003c\/h2\u003e\n\u003cp\u003eThe two constructions overlap at this end of the range, which is why buyers compare them.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eGalilean 4× (this pair)\u003c\/th\u003e\n\u003cth\u003ePrism 5×\u003c\/th\u003e\n\u003cth\u003ePrism 6×\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished field\u003c\/td\u003e\n\u003ctd\u003e70–75 mm\u003c\/td\u003e\n\u003ctd\u003e60–70 mm\u003c\/td\u003e\n\u003ctd\u003e55–65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField area relative\u003c\/td\u003e\n\u003ctd\u003e1.0×\u003c\/td\u003e\n\u003ctd\u003e0.8×\u003c\/td\u003e\n\u003ctd\u003e0.7×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished weight\u003c\/td\u003e\n\u003ctd\u003e65 g with the frame\u003c\/td\u003e\n\u003ctd\u003eNot published\u003c\/td\u003e\n\u003ctd\u003eNot published\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking-distance options\u003c\/td\u003e\n\u003ctd\u003eFour groups, 280–600 mm\u003c\/td\u003e\n\u003ctd\u003e340 \/ 420 \/ 500 \/ 550 mm, fixed positions\u003c\/td\u003e\n\u003ctd\u003e340 \/ 420 \/ 500 \/ 550 mm, fixed positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField as the eye moves off axis\u003c\/td\u003e\n\u003ctd\u003eNarrows\u003c\/td\u003e\n\u003ctd\u003eHolds its width\u003c\/td\u003e\n\u003ctd\u003eHolds its width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhat that means in practice\u003c\/td\u003e\n\u003ctd\u003eMore field, less steadiness, lighter than a prism pair of the same power\u003c\/td\u003e\n\u003ctd\u003eLess field, steadier image, better for long sessions at the margin\u003c\/td\u003e\n\u003ctd\u003eLeast field of the three, sharpest task instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"loupe-meta\"\u003eField area = (other midpoint \/ 72.5 mm)². Prism weights are not published on their listings, so no weight comparison is offered here.\u003c\/p\u003e\n\u003cp\u003eThe practical distinction is where you sit, not how hard you look. A Galilean at 4× rewards a clinician who works upright and moves the patient rather than the head; a prism pair rewards a clinician who leans in and needs the field to stay put while they do. A review of the category covers both across the 2.5–5.0× band and identifies the fixed working distance and the downward declination as the features carrying most of the postural effect (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/34210934\/\"\u003eJ Contemp Dent Pract 2021;22(3):310–315, PMID 34210934\u003c\/a\u003e, checked 2026-11-22).\u003c\/p\u003e\n\n\u003ch2\u003eWhich working-distance group should I choose?\u003c\/h2\u003e\n\u003cp\u003eFour groups, one per pair, locked at build: S covers 280–380 mm, R covers 360–460 mm, L covers 440–540 mm and XL covers 500–600 mm. The groups overlap because posture does.\u003c\/p\u003e\n\u003cp\u003eMeasure from the corner of your eye to the work surface, seated, in the posture you hold late in the day. Two rules make the choice easier. First, if the number sits inside two groups, take the group with room on both sides rather than the tighter one. Second, do not buy by height: two clinicians of the same height routinely land in different groups because of chair height, shoulder position and how far forward they carry the head.\u003c\/p\u003e\n\u003cp\u003eThe reason to take the measurement seriously at 4× rather than at 3.0× is depth of field. The published evidence on fitting is that review after purchase is rare — in a cross-sectional survey across the training-to-practice continuum, post-purchase fitting and magnification review were seldom carried out (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eJ Dent 2026;169:106661, PMID 41903621\u003c\/a\u003e, checked 2026-11-22) — and a pair that is 20 mm outside its design distance is blurred in a way the wearer usually blames on their own eyes.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the published specifications of the 4× pair?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue on this listing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e4.0×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical path\u003c\/td\u003e\n\u003ctd\u003eGalilean, two elements per barrel, flip-up frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view\u003c\/td\u003e\n\u003ctd\u003e70–75 mm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth of field\u003c\/td\u003e\n\u003ctd\u003eNot published as a figure; narrower than the 3.0× pair, which is why the working-distance measurement matters more here\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking distance\u003c\/td\u003e\n\u003ctd\u003e280–380 \/ 360–460 \/ 440–540 \/ 500–600 mm — four groups, one per pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e65 g with the frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterpupillary distance\u003c\/td\u003e\n\u003ctd\u003eAdjustable on the frame, along with declination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeadlight\u003c\/td\u003e\n\u003ctd\u003eNot included; the CliniEco Wireless Headlight clips to the same mount and is sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel reference\u003c\/td\u003e\n\u003ctd\u003eCLI-LOUPE-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarkets served\u003c\/td\u003e\n\u003ctd\u003eSold to Canadian addresses; US buyers contact us before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/galilean-flipup-4x_WD_2048.jpg?v=1795275407\" alt=\"Diagram of the four working-distance groups for the CliniEco 4× Galilean flip-up loupes — S 280–380 mm, R 360–460 mm, L 440–540 mm and XL 500–600 mm\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch2\u003eWhich procedures justify 4× in a general practice?\u003c\/h2\u003e\n\u003cp\u003eFour, and they are the ones where 3.0× leaves you leaning in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosterior composite placement\u003c\/strong\u003e — the cavity floor, the proximal box and the gingival margin in one field, without the whole quadrant competing for attention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrown and bridge seating\u003c\/strong\u003e — the margin, the contact and the adjacent tooth, at a power where a flash of excess cement is visible before the patient closes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEndodontic access preparation\u003c\/strong\u003e — the outline, the chamber floor and the orifices, stopping short of the canal work that wants 6× or 8×.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeriodontal and implant maintenance\u003c\/strong\u003e — probing depths read off the probe, and the tissue interface at a small radius of work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhat 4× does not replace is the prism pair for long margin sessions, where the field has to stay steady as you lean in. It also does not replace the 2.5× or 3.0× pair for hygiene, where the quadrant rather than the margin is what you need in view.\u003c\/p\u003e\n\n\u003ch2\u003eHow should flip-up optics be cleaned between patients?\u003c\/h2\u003e\n\u003cp\u003eThe published evidence on loupe contamination is not reassuring. In a pilot study of 25 student loupes, correctly disinfected pairs carried 2 CFU or fewer; after five days 20 percent exceeded 100 CFU and another 20 percent sat between 20 and 100 CFU, and pairs worn by students who had placed a restoration that day were contaminated 12 times more often (P \u0026lt; .01) (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eJADA 2019;150(8):689–694, PMID 31229256\u003c\/a\u003e, checked 2026-11-22).\u003c\/p\u003e\n\u003cp\u003eClean to the optics maker's instructions. The published reprocessing instructions for this class of loupe (HEINE MED 235113 rev01, and ExamVision's instructions) exclude immersion disinfection, machine cleaning and disinfection, ultrasound cleaning and sterilisation, and exclude alcoholic agents on a polarisation filter. Between patients the documented route is a microfibre cloth and the maker's own cleaning agent; a washer-disinfector, an ultrasonic bath or an autoclave will damage the coating on the barrels long before the frame fails.\u003c\/p\u003e\n\n\u003ch2\u003eWhat should a Canadian buyer confirm before ordering — and what differs in the United States?\u003c\/h2\u003e\n\u003cp\u003eThree items: the working-distance group, the frame weight if it matters to you (it is published here as 65 g), and the order terms for your address. The first is irrevocable; the second is a comfort decision; the third varies by destination.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere it leaves from\u003c\/td\u003e\n\u003ctd\u003eToronto, for Canadian addresses\u003c\/td\u003e\n\u003ctd\u003eToronto facility; US destinations arranged before the order — ask first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTax and duty treatment\u003c\/td\u003e\n\u003ctd\u003eGST\/HST appears at checkout\u003c\/td\u003e\n\u003ctd\u003eAssessed at entry and confirmed in writing; no figure is given on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe rule to cite internally\u003c\/td\u003e\n\u003ctd\u003eProvincial or territorial occupational health and safety regulation governs the clinic; the employer's written policy decides who is issued what\u003c\/td\u003e\n\u003ctd\u003e29 CFR 1910.1030(d)(3)(i) places the PPE duty on the employer and does not name a loupe; 29 U.S.C. 654(a)(1) carries the general duty, and Cal. Code Regs. Title 8 section 5110 applies where it applies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIf a student is buying\u003c\/td\u003e\n\u003ctd\u003eKeep the invoice; treatment is set by the institution and by your own filing\u003c\/td\u003e\n\u003ctd\u003eUnder IRS Publication 970, course-required equipment counts as a qualified education expense whether or not it is bought from the school\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor a purchase being defended against a cheaper frame, the published number to quote is that cost was named as the first barrier to magnification by 78.3 percent of 802 surveyed dental students, against 16.0 percent who named clinical use (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42814960\/\"\u003eEur J Dent Educ 2026, PMID 42814960\u003c\/a\u003e, checked 2026-11-22). The case for 4× is the four procedures above; the case against it is that a lighter pair at 3.0× covers more appointments per day.\u003c\/p\u003e\n\n\u003ch2\u003eWhat ships with the pair, and how is light added?\u003c\/h2\u003e\n\u003cp\u003eThe set arrives with the flip-up loupe pair and its clip mount (which opens to 15 mm), side shields, spare nose pads, a screwdriver, a microfibre cloth and an instruction sheet. Illumination is separate: the CliniEco Wireless Headlight clips to the same mount. At 70–75 mm the field is still wide enough to work without light in most operatories, but the margin work this pair is bought for is where a coaxial light changes what you can see, so it is worth deciding at the order rather than a year later.\u003c\/p\u003e\n\u003cp\u003eIf you would rather buy the combination in one step, the \u003ca href=\"\/products\/clinieco-galilean-loupes-4x-with-wireless-headlight-set\"\u003ethe 4× pair with the wireless headlight\u003c\/a\u003e bundles this frame with the headlight, and the \u003ca href=\"\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e sets out the terms for clinics ordering several pairs against measured working distances.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/41cb9efa3aa297d250721f480412f5f5_9be3138e-8299-4d84-9b17-c0fbcb2eba39.jpg?v=1790553756\" alt=\"CliniEco Wireless Dental Headlight clipped to a flip-up loupe frame — sold separately from the loupes\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch3\u003eRelated in this range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-galilean-flip-up-dental-loupes-3-5x\"\u003eCliniEco Galilean Flip-Up Dental Loupes 3.5×\u003c\/a\u003e — the 3.5× pair, which publishes a narrower field than this 4×.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-galilean-flip-up-dental-loupes-3-0x\"\u003eCliniEco Galilean Flip-Up Dental Loupes 3.0×\u003c\/a\u003e — 3.0× and 19 g lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-flip-up-dental-loupes-3-5x-magnification-adjustable-lightweight\"\u003eCliniEco Prism Flip-Up Dental Loupes 3.5×\u003c\/a\u003e — the prism 3.5× pair if the field has to stay steady as you lean in.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-prism-dental-loupes-6x\"\u003eCliniEco Prism Dental Loupes 6×\u003c\/a\u003e — 6× prism for endodontic detail.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/dental-loupes\"\u003eDental Loupes and Headlights\u003c\/a\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSources, checked 2026-11-22\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eA Comparative Study of Postural Impact and Benefits from Loupes in Undergraduate and Graduate Dentists\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2025 Dec;163:106162 (PMID 41072903).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/34210934\/\"\u003eDental Magnification Loupes: An Update of the Evidence\u003c\/a\u003e, \u003cem\u003eJ Contemp Dent Pract\u003c\/em\u003e 2021 Mar;22(3):310–315 (PMID 34210934).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eWork-Related Musculoskeletal Symptoms Across the Dental Training–Practice Continuum\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2026 Jun;169:106661 (PMID 41903621).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eDisinfection of dental loupes: A pilot study\u003c\/a\u003e, \u003cem\u003eJADA\u003c\/em\u003e 2019 Aug;150(8):689–694 (PMID 31229256).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42814960\/\"\u003eDental Students’ Awareness and Attitudes Toward Dental Magnification at the University of Jordan\u003c\/a\u003e, \u003cem\u003eEur J Dent Educ\u003c\/em\u003e 2026 (PMID 42814960).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\"\u003e29 CFR 1910.1030(d)(3)(i)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.law.cornell.edu\/uscode\/text\/29\/654\"\u003e29 U.S.C. 654(a)(1)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dir.ca.gov\/title8\/5110.html\"\u003eCal. Code Regs. Title 8, section 5110\u003c\/a\u003e · \u003ca href=\"https:\/\/www.irs.gov\/publications\/p970\"\u003eIRS Publication 970\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"loupe-meta\"\u003eImporter of record: CliniEco Medical, Health Canada establishment licence MDEL #35334 — importer and distributor — which is separate from the order terms. Pairs are assembled and despatched from our Toronto facility; freight, applicable tax and order terms for each destination are confirmed in writing on request. Specification values on this page are the published values for CLI-LOUPE-40, re-read from the listing and specification card on 2026-11-22.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- sku-inlink-block:v1 --\u003e\n\u003ch2\u003eRelated sizes and further reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clinieco-galilean-flip-up-dental-loupes-2-5x-sport-frame\"\u003eCliniEco Galilean Flip-Up Dental Loupes — 2.5× Magnification, Sport Aluminium Frame (Red or Black)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clinieco-galilean-flip-up-dental-loupes-3-0x\"\u003eCliniEco Galilean Flip-Up Dental Loupes — 3.0× Magnification, Adjustable, Lightweight\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuying guide: \u003ca href=\"\/blogs\/medical-supply-guide\/surgical-loupes-endodontics-implants-oral-surgery\"\u003eSurgical Loupes for Endodontics, Implants and Oral Surgery\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/dental-loupes\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CLI-LOUPE-25-01-hero_1500_4f39b8ac-cd61-4bb4-891a-09bbf53f2501.jpg?v=1794883527\" alt=\"CliniEco Galilean Flip-Up Dental Loupes — 4× Magnification, Adjustable, Lightweight — full range\" loading=\"lazy\" width=\"600\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"S · 280–380 mm","offer_id":49457059266782,"sku":"CLI-LOUPE-40","price":799.0,"currency_code":"USD","in_stock":true},{"title":"R · 360–460 mm","offer_id":49457059299550,"sku":"CLI-LOUPE-40-R","price":799.0,"currency_code":"USD","in_stock":true},{"title":"L · 440–540 mm","offer_id":49457059332318,"sku":"CLI-LOUPE-40-L","price":799.0,"currency_code":"USD","in_stock":true},{"title":"XL · 500–600 mm","offer_id":49457059365086,"sku":"CLI-LOUPE-40-XL","price":799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CLI-LOUPE-25-01-hero_1500_4f39b8ac-cd61-4bb4-891a-09bbf53f2501.jpg?v=1794883527","url":"https:\/\/clinieco.com\/products\/clinieco-galilean-flip-up-dental-loupes-4x","provider":"CliniEco Medical","version":"1.0","type":"link"}