{"product_id":"clinieco-ergo-angled-dental-loupes-5-5x-adjustable-pd","title":"CliniEco Ergo Angled Dental Loupes — 5.5×, Adjustable PD, Prism Optics","description":"\u003cstyle\u003e\n.loupe-prod{max-width:780px;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,sans-serif;color:#111827;line-height:1.65;font-size:16px}\n.loupe-prod h2{font-size:20px;color:#123a2f;border-bottom:2px solid #E5E7EB;padding-bottom:8px;margin:32px 0 12px}\n.loupe-prod h3{font-size:17px;color:#206270;margin:24px 0 8px}\n.loupe-prod p{margin:0 0 12px}\n.loupe-prod ul{margin:0 0 14px;padding-left:20px}\n.loupe-prod li{margin-bottom:8px}\n.loupe-prod img{max-width:100%;height:auto;border-radius:10px;display:block;margin:14px 0}\n.loupe-prod table{width:100%;border-collapse:collapse;margin:14px 0;font-size:14.5px}\n.loupe-prod th{background:#123a2f;color:#ffffff;text-align:left;padding:10px 12px;border:1px solid #123a2f;font-weight:600}\n.loupe-prod td{border:1px solid #E5E7EB;padding:10px 12px;vertical-align:text-top}\n.loupe-prod tbody td:first-child{background:#F9FAFB;font-weight:600}\n.loupe-note{background:#FFF7ED;border:1px solid #FDBA74;border-radius:8px;padding:14px 16px;font-size:14.5px;color:#7C2D12;margin:16px 0}\n.loupe-meta{font-size:14px;color:#4B5563}\n@media (max-width:600px){.loupe-prod{font-size:15.5px}.loupe-prod h2{font-size:18px}.loupe-prod table{font-size:13.5px}.loupe-prod th,.loupe-prod td{padding:8px 9px}}\n\u003c\/style\u003e\n\u003cdiv class=\"loupe-prod\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eCliniEco Ergo 5.5× angled dental loupes sit between the 4.5× pair that most clinicians start with and the 6.5× pair bought for endodontics and margins, and this page explains what that middle position actually buys you in field of view, working distance and posture at the chair.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat are CliniEco Ergo 5.5× angled dental loupes?\u003c\/h2\u003e\n\u003cp\u003eModel CLI-ERGO-55 is a fixed-mount pair with prism optics set at an angle to your line of sight, an interpupillary distance you adjust yourself, and one working distance chosen from four when the order is placed. No fitting appointment is involved: the frame is set by the person wearing it, in the room, in a few minutes.\u003c\/p\u003e\n\u003cp\u003eWhat separates it from the rest of the range is a single number. At 5.5× the published field of view is 65–74 mm, which sits a little under the 4.5× pair and a little over the 6.5× pair. That narrow band is the reason this model exists: it is for a clinician who has already found 4.5× slightly short of detail on margins but does not want to give up the quadrant at 6.5×.\u003c\/p\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/5cceb92f9a46bd01489147863d043d71.jpg?v=1794977724\" alt=\"CliniEco Ergo angled dental loupes, 5.5× magnification, prism optics, adjustable interpupillary distance, shown on a red frame\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch2\u003eIs 5.5× the right middle step between 4.5× and 6.5×?\u003c\/h2\u003e\n\u003cp\u003eIt is the right step for a specific pattern of work, and the arithmetic explains why. Moving from 4.5× to 5.5× takes the field of view from a midpoint of about 87 mm to about 69.5 mm — roughly 20% less width, and about 36% less area. Moving on from 5.5× to 6.5× takes it from about 69.5 mm to about 65 mm, about 6% less width and about 13% less area.\u003c\/p\u003e\n\u003cp\u003eSo the two steps are not equal. The first one buys a noticeable amount of resolution for a noticeable amount of field. The second one buys a small amount of resolution for a small amount of field. If your work is restorative with occasional endodontic access, 5.5× is where the curve still pays. If your work is endodontic access as a routine, the extra step to 6.5× is what the procedure wants, and you accept a one-tooth field to get it.\u003c\/p\u003e\n\u003cp\u003eThere is a second reason buyers land here. A published comparison of 146 students and 30 dentists found that the refractive prismatic design carried the lowest neck-risk score, while the Galilean design did not beat the naked eye on that metric, and that selection knowledge was incomplete in both groups (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eJ Dent 2025;163:106162, PMID 41072903\u003c\/a\u003e, checked 2026-11-21). The practical reading is that the design family, not the badge on the frame, does much of the ergonomic work — which is why an angled prism pair at 5.5× is a reasonable place to stop rather than pushing to the highest power in the range.\u003c\/p\u003e\n\n\u003ch2\u003eHow much field of view do you actually lose, model by model?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eField of view (nominal)\u003c\/th\u003e\n\u003cth\u003eFrame weight, as published\u003c\/th\u003e\n\u003cth\u003eField width versus this page's 5.5×\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eErgo 3.5×\u003c\/td\u003e\n\u003ctd\u003e95–115 mm\u003c\/td\u003e\n\u003ctd\u003e48–51 g\u003c\/td\u003e\n\u003ctd\u003eAbout 1.55× wider\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eErgo 4.5×\u003c\/td\u003e\n\u003ctd\u003e82–92 mm\u003c\/td\u003e\n\u003ctd\u003e43 g sport \/ 46 g titanium\u003c\/td\u003e\n\u003ctd\u003eAbout 1.25× wider\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eErgo 5.5× (this listing)\u003c\/td\u003e\n\u003ctd\u003e65–74 mm\u003c\/td\u003e\n\u003ctd\u003e51 g sport \/ 54 g titanium\u003c\/td\u003e\n\u003ctd\u003e1.0 — the reference row\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eErgo 6.5×\u003c\/td\u003e\n\u003ctd\u003e62–68 mm\u003c\/td\u003e\n\u003ctd\u003e52 g sport \/ 55 g titanium\u003c\/td\u003e\n\u003ctd\u003eAbout 7% narrower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"loupe-meta\"\u003eEach row quotes the field of view and frame weight published on that model's own listing, re-read on 2026-11-21. The comparison column is arithmetic on those published midpoints. Where a listing states that field of view is confirmed against the ordered working distance, read the figure here as the nominal range for the series.\u003c\/p\u003e\n\u003cp\u003eOne thing worth noticing in that table: frame weight does not fall as magnification rises. The 4.5× pair is listed lighter than both the 3.5× and the 5.5×. That is how the listings are published rather than a physical rule, and it is a good reason to ask for the weight of the exact configuration you are ordering if you plan to wear the pair for six-hour sessions.\u003c\/p\u003e\n\n\u003ch2\u003eHow do you choose a working distance without a fitting appointment?\u003c\/h2\u003e\n\u003cp\u003eThe four positions are 360, 460, 520 and 560 mm, and the pair is built to one of them. Because that number cannot be changed at the chair, it is worth measuring twice.\u003c\/p\u003e\n\u003cp\u003eMeasure with the patient in position, not at an empty chair: sit as you normally sit, let your arms hang, then open your eyes where they would naturally settle and have a colleague measure from your eye to the surface. Three readings on three different days are better than one. If the readings straddle two positions, order the shorter one — the error you can correct by sitting back slightly is smaller than the error you correct by leaning in all day.\u003c\/p\u003e\n\u003cp\u003eTwo things this decision interacts with. Chair height matters more than most buyers expect: if you work with the patient's head high, your natural distance shortens. And if two clinicians will share one pair, the shorter distance flatters the taller operator, so choose for the shorter natural distance in the pair of you.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the specifications of the 5.5× Ergo?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue on this listing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e5.5×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptics\u003c\/td\u003e\n\u003ctd\u003ePrism, angled optical path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view\u003c\/td\u003e\n\u003ctd\u003e65–74 mm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking distance\u003c\/td\u003e\n\u003ctd\u003e360 \/ 460 \/ 520 \/ 560 mm — one position chosen at order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without lenses\u003c\/td\u003e\n\u003ctd\u003e51 g with the sport frame, 54 g with the titanium frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterpupillary distance\u003c\/td\u003e\n\u003ctd\u003eAdjustable on the frame; range confirmed with your order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeadlight\u003c\/td\u003e\n\u003ctd\u003eNot included; the Core wireless headlight clips on and is sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel code\u003c\/td\u003e\n\u003ctd\u003eCLI-ERGO-55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/74ac1e623cbefde0bc5187a744836d1f.jpg?v=1794987125\" alt=\"Specification card for the CliniEco CLI-ERGO-55 angled dental loupes — 5.5× magnification, 65–74 mm field of view, 51 g sport or 54 g titanium, four working distances\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch2\u003eWhat does the first month with an angled pair feel like?\u003c\/h2\u003e\n\u003cp\u003eNew users describe three drawbacks honestly: a restricted field, a fixed viewpoint, and discomfort while the habit forms; the adaptation period is short, and the cost-benefit trade-off is explicit in the published work (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42424270\/\"\u003ePLOS One 2026;21(7):e0353061, PMID 42424270\u003c\/a\u003e). At 5.5× the restriction is real but not severe: the field still holds a tooth and its neighbours, so you do not have to rebuild your sense of where you are in the arch.\u003c\/p\u003e\n\u003cp\u003eStructured practice shortens the curve. In a programme with 31 students across five sessions and 13 hours in total, posture compliance improved (p = .044) and reported pain fell (p = .006) (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41472520\/\"\u003eEur J Dent Educ 2026;30(3):1316–1324, PMID 41472520\u003c\/a\u003e, checked 2026-11-21). The practical version for a working clinician is unglamorous: short sessions at first, only at your measured working distance, and stop when the image starts to drift rather than pushing through, because drifting means you have moved your head instead of your frame.\u003c\/p\u003e\n\u003cp\u003eOne more finding is worth knowing before you buy anything in this category. Across 191 participants, the smallest detail that could be resolved differed by up to 300% between individuals, while self-assessment and measured performance correlated only weakly (r = 0.27) (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29603638\/\"\u003eInt J Dent Hyg 2018;16(3):357–361, PMID 29603638\u003c\/a\u003e). Clinicians are poor judges of their own magnified vision, which is the argument for measuring the working distance properly on the front end rather than trusting a first impression at a trade show.\u003c\/p\u003e\n\n\u003ch2\u003eWhy does the optical path angle matter more than the power?\u003c\/h2\u003e\n\u003cp\u003eIn a straight telescope, the site has to be brought up to the line of sight, which means flexing the neck for anything in the lower arch. An angled barrel moves the optics instead of the head: the path turns inside the tube, leaves the eyepiece close to level, and arrives at a site below it.\u003c\/p\u003e\n\u003cp\u003eThe measured effect in this category is consistent in direction but modest in size. A modelled study of angled loupes in ophthalmic microsurgery reported cervical load of 18.7 lbf with no loupes, 16.3 lbf with through-the-lens loupes and 9.6 lbf with the angled design — a 41.1% reduction against through-the-lens (\u003cem\u003eSafety\u003c\/em\u003e 2026;12(1):24). A manikin study of 29 hygiene students and faculty measured head tilt about 6.3° lower at the mandibular arch and about 4.1° lower at the maxillary arch with a declination-adjustable design (\u003cem\u003eJ Dent Hyg\u003c\/em\u003e 2021;95(3):59–64). A study of 24 hygienists compared a custom declination against a standard one and found mean torso flexion of 16.52° against 22.27° (F = 7.14, p = .01), with no significant difference at the neck (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/33000517\/\"\u003eInt J Dent Hyg 2021;19(1):106–113, PMID 33000517\u003c\/a\u003e).\u003c\/p\u003e\n\u003cdiv class=\"loupe-note\"\u003e\n\u003cstrong\u003eRead the size of the effect, not just its direction.\u003c\/strong\u003e These are studies of design categories, several of them simulated, none of them a trial of this pair, and one of them on ophthalmic surgery rather than dentistry. They support choosing an angled design if the position of your head is the thing you want to change. They do not support any promise that a purchase will fix an existing neck problem, and we do not make that promise.\u003c\/div\u003e\n\n\u003ch2\u003eWhat should a practice, residency or school check before a group order?\u003c\/h2\u003e\n\u003cp\u003eGroup orders go wrong in the same three places, so it is worth naming them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePer-person working distance.\u003c\/strong\u003e A single order of ten pairs at one distance will fit perhaps half the group. Collect each person's measurement before the purchase order is raised; that single step is what separates a group order from ten individual mistakes. The published evidence on why this is skipped is not flattering: in a survey of 308 loupe owners, post-purchase fitting and magnification review were rarely carried out (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eJ Dent 2026;169:106661, PMID 41903621\u003c\/a\u003e).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirement language for students.\u003c\/strong\u003e Whether a loupe purchase qualifies for education-related tax treatment depends on whether the programme requires it. Under \u003ca href=\"https:\/\/www.irs.gov\/publications\/p970\"\u003eIRS Publication 970\u003c\/a\u003e, course-required books, supplies and equipment count as qualified education expenses whether or not bought from the school, while non-required equipment does not. The student makes the calculation; the programme's job is to say plainly in the syllabus whether magnification is required. Cost is the first barrier in the published data — 78.3% of 802 students named it, against 16.0% clinical use (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42814960\/\"\u003eEur J Dent Educ 2026, PMID 42814960\u003c\/a\u003e, checked 2026-11-21).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the pair is and is not, in writing.\u003c\/strong\u003e Under \u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\"\u003e29 CFR 1910.1030(d)(3)(i)\u003c\/a\u003e an employer must provide appropriate PPE, including eye protection, at no cost; a loupe is not the eye protection that paragraph means, and a file that says otherwise will not hold up. If the purchase is justified on posture grounds, cite the general duty in \u003ca href=\"https:\/\/www.law.cornell.edu\/uscode\/text\/29\/654\"\u003e29 U.S.C. 654(a)(1)\u003c\/a\u003e and, where it applies, the state rule: \u003ca href=\"https:\/\/www.dir.ca.gov\/title8\/5110.html\"\u003eCalifornia Code of Regulations, Title 8, section 5110\u003c\/a\u003e triggers a repetitive motion injuries programme when more than one employee has an objectively diagnosed repetitive motion injury predominantly caused by a repetitive job or process, among employees doing the same activity, reported within the previous 12 months.\u003c\/p\u003e\n\n\u003ch2\u003eHow should an angled pair be looked after?\u003c\/h2\u003e\n\u003cp\u003eTwo habits carry most of the benefit: a routine clean after every patient, and no heat. In a study of 25 student loupes, correctly disinfected pairs carried 2 CFU or fewer, but after five days 20% exceeded 100 CFU and 20% sat between 20 and 100 CFU; pairs worn by students who had placed a restoration that day were contaminated 12 times more often (P \u0026lt; .01) (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eJADA 2019;150(8):689–694, PMID 31229256\u003c\/a\u003e, checked 2026-11-21).\u003c\/p\u003e\n\u003cp\u003eUse the instructions supplied with the pair. Manufacturer documents in this category are specific: HEINE's reprocessing instructions (MED 235113 rev01) exclude immersion disinfection, machine cleaning and disinfection, ultrasound cleaning and sterilisation of the loupes, and exclude alcoholic agents on the polarisation filter, while ExamVision's instructions exclude alcohol entirely and exclude autoclaving and ultrasonic cleaning. If a clinic's standard wipe contains alcohol, check the optics manufacturer's document before adopting it for the loupes.\u003c\/p\u003e\n\n\u003ch2\u003eWhat is in the box, and do you need the headlight?\u003c\/h2\u003e\n\u003cp\u003eThe pair, assembled to your chosen working distance, plus a protective case, a microfibre cloth, spare nose pads and side shields. The headlight is a separate item and clips to the frame; it is worth deciding at the same time as the loupes, because a light bought later has to match the mount you already own.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CLI-HL-CORE-01-hero_1500.jpg?v=1794062536\" alt=\"CliniEco Core wireless dental headlight for loupe frames, front view on a white background\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch3\u003eRelated in this range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-ergo-angled-dental-loupes-6-5x-adjustable-pd\"\u003eErgo Angled Dental Loupes 6.5×\u003c\/a\u003e — the same frame for endodontic and margin work where the field can be one tooth.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-ergo-angled-dental-loupes-4-5x-adjustable-pd\"\u003eErgo Angled Dental Loupes 4.5×\u003c\/a\u003e — the usual first angled pair, with a wider field.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-ergo-angled-dental-loupes-3-5x-adjustable-pd\"\u003eErgo Angled Dental Loupes 3.5×\u003c\/a\u003e — the wide end of the range.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/clinieco-prism-dental-loupes-5x\"\u003ePrism Dental Loupes 5×\u003c\/a\u003e — prism optics on a flip-up frame, at a lower magnification.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/dental-loupes\"\u003eDental Loupes and Headlights\u003c\/a\u003e — the full range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSources\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eMagnification loupes: design, posture and selection knowledge\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2025, 163, 106162 (PMID 41072903).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42424270\/\"\u003eLearning to use dental loupes\u003c\/a\u003e, \u003cem\u003ePLOS One\u003c\/em\u003e 2026, 21(7), e0353061 (PMID 42424270).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41472520\/\"\u003eStructured loupe training for dental students\u003c\/a\u003e, \u003cem\u003eEur J Dent Educ\u003c\/em\u003e 2026, 30(3), 1316–1324 (PMID 41472520).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29603638\/\"\u003eSelf-assessment versus measured magnification performance\u003c\/a\u003e, \u003cem\u003eInt J Dent Hyg\u003c\/em\u003e 2018, 16(3), 357–361 (PMID 29603638).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mdpi.com\/2313-576X\/12\/1\/24\"\u003eBiomechanical and psychometric evaluation of angled loupes in ophthalmic surgery\u003c\/a\u003e, \u003cem\u003eSafety\u003c\/em\u003e 2026, 12(1), 24.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/jdh.adha.org\/content\/jdenthyg\/95\/3\/59.full\"\u003eDental magnification loupes and head tilt angles among dental hygiene students and faculty\u003c\/a\u003e, \u003cem\u003eJournal of Dental Hygiene\u003c\/em\u003e 2021, 95(3), 59–64.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/33000517\/\"\u003eCustom versus standard declination angles in dental loupes\u003c\/a\u003e, \u003cem\u003eInt J Dent Hyg\u003c\/em\u003e 2021, 19(1), 106–113 (PMID 33000517).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eFitting and magnification review after purchase\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2026, 169, 106661 (PMID 41903621).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eBacterial contamination of dental magnification loupes\u003c\/a\u003e, \u003cem\u003eJADA\u003c\/em\u003e 2019, 150(8), 689–694 (PMID 31229256).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/42814960\/\"\u003eClinical use of magnification loupes among dental students\u003c\/a\u003e, \u003cem\u003eEur J Dent Educ\u003c\/em\u003e 2026 (PMID 42814960).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.irs.gov\/publications\/p970\"\u003eIRS Publication 970\u003c\/a\u003e, \u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\"\u003e29 CFR 1910.1030(d)(3)(i)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.law.cornell.edu\/uscode\/text\/29\/654\"\u003e29 U.S.C. 654(a)(1)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.dir.ca.gov\/title8\/5110.html\"\u003eCal. Code Regs. Title 8, section 5110\u003c\/a\u003e. All sources checked 2026-11-21.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThis model is currently sold in Canada only. It ships from our Toronto warehouse. US buyers can reach us at alina@clinieco.ca before ordering.\u003c\/p\u003e\n\n\u003cp class=\"loupe-meta\"\u003eImporter of record: CliniEco Medical, Health Canada establishment licence MDEL #35334. Manufactured for CliniEco by an optical instrument factory in Nanjing, China; model reference EM\/EMD. Pairs are assembled and despatched from our Toronto facility; freight and order terms for each destination are confirmed in writing on request.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- sku-inlink-block:v1 --\u003e\n\u003ch2\u003eRelated sizes and further reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clinieco-ergo-angled-dental-loupes-3-5x-with-wireless-headlight\"\u003eCliniEco Ergo Angled Dental Loupes + Wireless Headlight Set — 3.5×, Adjustable PD\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clinieco-ergo-angled-dental-loupes-3-5x-adjustable-pd\"\u003eCliniEco Ergo Angled Dental Loupes — 3.5×, Adjustable PD, No Fitting Visit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuying guide: \u003ca href=\"\/blogs\/medical-supply-guide\/surgical-loupes-endodontics-implants-oral-surgery\"\u003eSurgical Loupes for Endodontics, Implants and Oral Surgery\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/dental-loupes\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/5cceb92f9a46bd01489147863d043d71.jpg?v=1794977724\" alt=\"CliniEco Ergo Angled Dental Loupes — 5.5×, Adjustable PD, Prism Optics — full range\" loading=\"lazy\" width=\"600\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"360 mm","offer_id":49462239592670,"sku":"CLI-ERGO-55","price":1362.0,"currency_code":"USD","in_stock":false},{"title":"460 mm","offer_id":49462239625438,"sku":"CLI-ERGO-55-460","price":1362.0,"currency_code":"USD","in_stock":false},{"title":"520 mm","offer_id":49462239658206,"sku":"CLI-ERGO-55-520","price":1362.0,"currency_code":"USD","in_stock":false},{"title":"560 mm","offer_id":49462239690974,"sku":"CLI-ERGO-55-560","price":1362.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/5cceb92f9a46bd01489147863d043d71.jpg?v=1794977724","url":"https:\/\/clinieco.com\/products\/clinieco-ergo-angled-dental-loupes-5-5x-adjustable-pd","provider":"CliniEco Medical","version":"1.0","type":"link"}