{"product_id":"aurelia-transform-100-nitrile-exam-gloves-3-2-mil-medical-grade-ice-blue-1000-case","title":"Aurelia Transform 100 Nitrile Exam Gloves — 3.2 mil, Medical Grade, Ice Blue, 1,000 Gloves per Case (10 × 100)","description":"\u003cdiv class=\"product-description\"\u003e\n\u003cp class=\"ce-lead\"\u003e\u003cstrong\u003eThese are Aurelia Transform 100 nitrile examination gloves at 3.2 mil, powder-free and latex-free, in ice blue, sold 1,000 gloves to a case as ten boxes of 100, and the thin film is the one to choose when feel through the glove decides the outcome and gloves change often.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/GLOVE-TRANSFORM-HERO-logo-20261110_8cf3c979-cea9-4d13-8950-4bee4038a4e3.jpg?v=1794342305\" alt=\"Aurelia Transform 100 3.2 mil nitrile examination gloves, ice blue, 1,000 gloves per case\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat is a 3.2 mil glove for?\u003c\/h2\u003e\n\u003cp\u003eA 3.2 mil film is about tactile transmission. At this weight a clinician can feel a pulse, a margin, a suture or the resistance of a small instrument through the glove, which is the reason thin nitrile is standard in examination, hygiene and fine-work settings. The trade is durability: a thin film snags more readily and has to be changed sooner when the work involves sharp edges, so thin gloves are a poor fit for long wet procedures and a good fit for high-turnover, short encounters.\u003c\/p\u003e\n\u003cp\u003eThe film weight also affects how the glove dons and how it fits across the knuckles. Clinicians who wear a 3.2 mil glove for one shift and a 4.5 mil glove the next often find they want the same nominal size in both — the lighter film gives a little more stretch at the knuckle and a closer feel at the fingertip.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/TRF100_05_fullcase-open-10boxes.jpg?v=1792787972\" alt=\"Open case of Aurelia Transform 100 blue nitrile gloves with ten 100-glove boxes arranged in the case\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat exactly is in a case, and how far does one box go?\u003c\/h2\u003e\n\u003cp\u003eA case holds 1,000 gloves as ten dispenser boxes of 100. Each box is a working unit for one operatory, and the arithmetic of a box is worth knowing because it sets the reorder point: 100 gloves is 50 pairs, and 50 pairs is roughly two to four days of examination work for a single clinician, depending on how often the pair is changed. A clinic that waits for a box to empty before reordering is one busy day away from a shortage.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003cth\u003eGloves\u003c\/th\u003e\n\u003cth\u003ePairs\u003c\/th\u003e\n\u003cth\u003eWhat it covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispenser box\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eRoughly 2–4 days for one clinician at 12–25 encounters a day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalf case\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003eTwo to three weeks for one clinician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003eAbout a month for one clinician; ~two weeks for two chairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePallet layer (for planning)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eConfirm with the supplier before committing storage space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eHow do you choose the size when the case carries one size only?\u003c\/h2\u003e\n\u003cp\u003eSize is the purchase decision that most often goes wrong, because a case is a single size and a team is not. Measure once, properly, rather than ordering the size people wore at a previous employer: the nominal scale (S, M, L, XL) is not standardised between manufacturers, and a 3.2 mil film fits differently from a 4.5 mil film in the same nominal size.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eHow it should feel\u003c\/th\u003e\n\u003cth\u003eCommon sizing error\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003eSnug at the base of the fingers, no tightness across the palm\u003c\/td\u003e\n\u003ctd\u003eOrdering S for a wearer who needs M because the film stretches on donning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM\u003c\/td\u003e\n\u003ctd\u003eFull extension of the fingers without pulling at the web space\u003c\/td\u003e\n\u003ctd\u003eAssuming M is the default and ordering a whole case before a trial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eNo tension across the knuckles when the hand is closed\u003c\/td\u003e\n\u003ctd\u003eWearing L to make donning faster, which shortens the cuff and reduces grip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXL\u003c\/td\u003e\n\u003ctd\u003eCuff sits at the wrist without rolling\u003c\/td\u003e\n\u003ctd\u003eSplitting a case between L and XL without confirming the split with the team\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe practical test takes a minute: put the glove on, close the hand into a fist, and check that the web between thumb and index finger is not under tension. A glove that is too tight at the cuff rolls down during the appointment, and a rolled cuff is where contamination reaches the wrist.\u003c\/p\u003e\n\n\u003ch2\u003eIs a thin glove still a medical-grade barrier?\u003c\/h2\u003e\n\u003cp\u003eYes — thickness and barrier class are separate questions. Nitrile examination gloves are made to ASTM D6319, which sets minimum tensile strength (14 MPa) and elongation at break (500% before aging) together with a watertightness test for pinholes. A 3.2 mil glove is tested against the same standard as a 4.5 mil glove; what changes with film weight is how the glove behaves in use, not which specification it meets.\u003c\/p\u003e\n\u003cp\u003eThe listing also records this glove as chemotherapy-tested. That claim should be read against ASTM D6978, the practice that measures how quickly a chemotherapy drug permeates a glove material: permeation depends on the polymer formulation and on temperature and force, not on calliper. If the glove is being bought for chemotherapy handling, match the ASTM D6978 statement to the drug list the facility actually handles rather than relying on \"medical grade\" alone.\u003c\/p\u003e\n\n\u003ch2\u003eWhat do glove failures in real use look like?\u003c\/h2\u003e\n\u003cp\u003eThey are mostly invisible. A prospective study on two intensive care units collected 1,500 consecutively used examination glove pairs and found micro-perforations in 10.3% of them with a water-tightness test, with significant durability differences between brands that could not be predicted from the manufacturers' technical data. Only 26% of the pairs had been worn longer than 15 minutes, and the authors proposed changing gloves after about 15 minutes as a practical compromise.\u003c\/p\u003e\n\u003cp\u003eA laboratory study of 30 nitrile exam products, tested new and after two hours of simulated whole-glove movement, found that movement changed the leak results. For a thin film the lesson is sharper than for a heavy one: the glove is doing its job only while it is intact, and the change rule — replace when contaminated, torn or punctured, and do not wear one pair across unrelated tasks — is the control that keeps a 3.2 mil glove safe in high-turnover work.\u003c\/p\u003e\n\n\u003ch2\u003eHow many cases does a clinic actually need?\u003c\/h2\u003e\n\u003cp\u003eEstimate from encounters and from the change rate, then round up, because a case is a month of supply for one clinician and half that for two chairs. The table below uses two gloves per encounter and a modest allowance for extra changes, which is the pattern in examination-heavy settings.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eEncounters per day\u003c\/th\u003e\n\u003cth\u003eGloves per day\u003c\/th\u003e\n\u003cth\u003eGloves per 21-day month\u003c\/th\u003e\n\u003cth\u003eCases at 1,000\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne clinician, 15 encounters\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo clinicians, 25 encounters\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e1,050\u003c\/td\u003e\n\u003ctd\u003e1.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo chairs, 32 encounters\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e1,344\u003c\/td\u003e\n\u003ctd\u003e1.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree chairs, 45 encounters\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e1,890\u003c\/td\u003e\n\u003ctd\u003e1.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWalk-in clinic, 60 encounters\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e2,520\u003c\/td\u003e\n\u003ctd\u003e2.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo corrections are worth applying. First, a clinic that changes gloves between every task within an encounter — as specimen handling and any chemotherapy work requires — should add half again to the monthly figure. Second, a clinic that uses exam gloves for cleaning and disinfection is buying the wrong glove for that task; a utility glove is cheaper to consume and a thin film tears on a rough surface, which is how a month's supply disappears in three weeks.\u003c\/p\u003e\n\n\u003ch2\u003eWhat should a US buyer confirm before reordering?\u003c\/h2\u003e\n\u003cp\u003eConfirm the device status: in the United States a non-powdered patient examination glove is a Class I device under 21 CFR 880.6250, and Class I does not mean exempt — only a finger cot is excepted from premarket notification in that section, so an examination glove should trace to a 510(k)-cleared device. Confirm the standard reference (ASTM D6319) and, if chemotherapy handling is part of the use case, the ASTM D6978 statement. Confirm the size split and the case configuration of ten boxes of 100. Freight and duties for United States addresses are shown at checkout; for a group or long-term-care contract, the institutional account enquiry is the route to a written quotation with sizes and delivery addresses confirmed.\u003c\/p\u003e\n\n\u003ch2\u003eHow should a thin glove be stored and handled?\u003c\/h2\u003e\n\u003cp\u003eStore cases in a dry room away from heat, sunlight and the sterilisation area, keep the dispenser boxes closed between uses, and rotate so the oldest case is opened first. Do not decant gloves loose into a drawer — a thin film picks up dust and creases, and a creased glove is where a pinhole starts. Hand hygiene before donning and after removal remains the control that the WHO hand hygiene guidance and the glove-use literature both emphasise, because a glove that is worn instead of washing hands transfers contamination from one surface to the next.\u003c\/p\u003e\n\n\u003ch3\u003eSources, checked 2026-11-21\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/store.astm.org\/d6319-19.html\" rel=\"nofollow noopener\" target=\"_blank\"\u003eASTM D6319-19 — Standard Specification for Nitrile Examination Gloves for Medical Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/store.astm.org\/d6978-05r19.html\" rel=\"nofollow noopener\" target=\"_blank\"\u003eASTM D6978-05(2019) — Resistance of Medical Gloves to Permeation by Chemotherapy Drugs\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/21\/880.6250\" rel=\"nofollow noopener\" target=\"_blank\"\u003e21 CFR 880.6250 — Non-powdered patient examination glove (Class I; finger cot exemption)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\" rel=\"nofollow noopener\" target=\"_blank\"\u003e29 CFR 1910.1030(d)(3)(ix) — Gloves: when required, when replaced\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.1030\" rel=\"nofollow noopener\" target=\"_blank\"\u003eOSHA Bloodborne Pathogens standard, 1910.1030\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3666964\/\" rel=\"nofollow noopener\" target=\"_blank\"\u003eDurability of examination gloves used on intensive care units (BMC Infect Dis, 2013)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3124250\/\" rel=\"nofollow noopener\" target=\"_blank\"\u003eIntegrity of disposable nitrile exam gloves exposed to simulated movement (2011)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC12082975\/\" rel=\"nofollow noopener\" target=\"_blank\"\u003eImproper glove use increases infection risk (Antimicrob Resist Infect Control, 2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC10015298\/\" rel=\"nofollow noopener\" target=\"_blank\"\u003eFentanyl and carfentanil permeation through commercial disposable gloves (2020)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.who.int\/publications\/i\/item\/9789241597906\" rel=\"nofollow noopener\" target=\"_blank\"\u003eWHO Guidelines on Hand Hygiene in Health Care\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePacking and what is included\u003c\/h3\u003e\n\u003cp\u003e1,000 gloves per case, as ten dispenser boxes of 100, in sizes S, M, L and XL, ice blue, powder-free and latex-free. The case carries one size only. Related reading: \u003ca href=\"\/collections\/aurelia-nitrile-exam-gloves-by-thickness\"\u003ethe Aurelia 3.2, 4.0 and 4.5 mil comparison\u003c\/a\u003e, \u003ca href=\"\/products\/aurelia-nitrile-examination-gloves-protege-4-0-mil-powder-free-chemo-grade-100-count\"\u003ethe 4.0 mil Protégé glove\u003c\/a\u003e, \u003ca href=\"\/products\/aurelia-nitrile-examination-gloves-robust-5-0-mil-powder-free-fully-textured-100-count\"\u003ethe 4.5 mil Robust glove\u003c\/a\u003e, and \u003ca href=\"\/blogs\/medical-supply-guide\/nitrile-exam-gloves-single-chair-dental-practice-ontario-per-month\"\u003emonthly glove counts for a single-chair practice\u003c\/a\u003e. To size a month against your own encounter count, use the \u003ca href=\"\/pages\/clinic-supply-planner\"\u003eclinic supply and cost planner\u003c\/a\u003e; for a multi-site or institutional quotation, open an \u003ca href=\"\/pages\/wholesale\"\u003einstitutional account enquiry\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"soco-meta\"\u003eImported and distributed in Canada by CliniEco Medical — MDEL #35334. Specifications and packing read from the live listing on 2026-11-21.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Supermax Healthcare Canada (Aurelia)","offers":[{"title":"S","offer_id":49261182058718,"sku":"AUR-NG-TRF100-32-S","price":71.09,"currency_code":"USD","in_stock":true},{"title":"M","offer_id":49261182091486,"sku":"AUR-NG-TRF100-32-M","price":71.09,"currency_code":"USD","in_stock":true},{"title":"L","offer_id":49261182124254,"sku":"AUR-NG-TRF100-32-L","price":71.09,"currency_code":"USD","in_stock":true},{"title":"XL","offer_id":49261182157022,"sku":"AUR-NG-TRF100-32-XL","price":71.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/GLOVE-TRANSFORM-HERO-logo-20261110_8cf3c979-cea9-4d13-8950-4bee4038a4e3.jpg?v=1794342305","url":"https:\/\/clinieco.com\/products\/aurelia-transform-100-nitrile-exam-gloves-3-2-mil-medical-grade-ice-blue-1000-case","provider":"CliniEco Medical","version":"1.0","type":"link"}